Skip to content

Description

The Ferroli Omnia S 3.2 (code 0XHKASWA) is a split air-to-water reversible heat pump rated 10.0 kW, single-phase, for heating, cooling and domestic hot water with an external cylinder. It works with R32 gas and has a standard 3 kW electric booster heater.

Bright living room with white sofa and lake view, beside an outdoor heat pump and a white wall-mounted boiler

DC inverter compressor with Full Inverter on compressor, fan and pump

Ferroli's Full Inverter technology modulates in direct current the three components that consume the most energy: compressor, fan and pump. The output follows the heat load, with high efficiency and energy savings. Inrush currents are reduced, with no surges on the grid, and the useful life of the components is longer.

R32 gas with GWP 675

R32 refrigerant has a GWP of 675, about a third of that of R410A. With this gas the Omnia S 3.2 combines high efficiency with a reduced environmental impact.

Outdoor and indoor units connected with R32 pipework

The outdoor unit houses the refrigerant circuit, with compressor, fan and air-side heat exchanger. The indoor unit houses the hydraulic circuit, with high-efficiency circulator and expansion vessel already installed. The two units are connected by R32 gas pipes.

Diagram with legend of the internal components of a split air-to-water heat pump, with indoor and outdoor units

Split installation without freezing risk

With the outdoor unit separated from the hydraulic circuit, the split installation avoids freezing problems down to -25 °C, even during a power cut. Outdoor monobloc units, by contrast, have electric antifreeze heaters, which do not work without power.

Heating with water up to 65 °C

The Omnia S 3.2 produces hot water up to 65 °C, so it is suitable for underfloor heating, fan coil units or radiators. It can work as the sole heat source for the system or be combined with other sources, such as a boiler.

3 kW electric booster in single-phase, 6 kW in three-phase

As standard the Omnia S 3.2 has a 3 kW electric booster. For three-phase models the booster is 6 kW.

Noise levels among the lowest on the market

The noise levels of the Omnia S 3.2 are among the lowest on the market. Silent mode reduces the maximum compressor frequency and fan speed, with 2 levels programmable by daily time bands, for example at night.

Weather compensation with standard curves

Weather curves are standard, for both heating and cooling, and control uses the outdoor air temperature sensor pre-fitted on the outdoor unit. Full Inverter modulation maintains the desired setpoints and optimises consumption.

Control panel with digital screen, + and − buttons and function icons, of a heat pump

2.8-inch display and on-unit controls

The controls are included on the unit, with Capsense interface and a 2.8-inch graphic display. With the optional Connect CRP, up to 8 thermostats can be managed, 7 Connect CRP Zone units and 1 Connect CRP timer thermostat, across 2 zones, one direct and one mixed. The Modbus protocol allows management via an external BMS, and control via iOS and Android app requires the optional Connect CRP.

Domestic hot water with external cylinder

DHW requires an external cylinder, not supplied with the unit. The DHW temperature sensor is fitted to the cylinder by the installer. When the temperature drops below the set value, the unit enters DHW mode with a dedicated setpoint, and the 3-way diverter valve is supplied as standard. The Fast DHW function activates all available energy sources to bring the cylinder to setpoint in the shortest possible time.

Cylinder electric heater for booster, anti-legionella and backup

In DHW mode the unit manages an electric heater in the cylinder, as a booster, for the anti-legionella function or as a backup source in case of a fault. The anti-legionella function sets weekly cycles and requires an electric heater in the cylinder or a boiler as booster.

Smart grid: contacts for photovoltaics and grid

The unit has 2 digital inputs for photovoltaics and the electricity grid. The EVU contact signals when photovoltaics are producing and the unit raises the DHW setpoint to improve self-consumption. The SG contact signals when energy costs more and the heat pump limits itself, according to customisable settings, if the utility allows it.

ON/OFF, HEATING/COOLING, ECO and time programming

The unit is switched on and off by an external contact, for example from the zone thermostat, and operation follows the controller settings. With the HEATING/COOLING contact it receives the summer/winter changeover signal. ECO mode has a dedicated setpoint settable with a daily time band. With the optional Connect CRP, weekly time programming defines for each day and band the mode (COOLING, HEATING or DHW) and the setpoints. Frost protection operates in heating, with circulator ON and any electric booster.

Technical table of the outdoor unit of a heat pump, with efficiencies and energy classes

Performance data table of an air-to-water heat pump, with heating and cooling outputs

Frequently asked questions

Which refrigerant does the Ferroli Omnia S 3.2 use?
The Ferroli Omnia S 3.2 uses R32 refrigerant gas, with a GWP of 675, about a third of that of R410A.
Can the Ferroli Omnia S 3.2 produce domestic hot water?
Yes, with an external cylinder not supplied. The Omnia S 3.2 produces hot water up to 65 °C and manages DHW with a dedicated sensor, a standard 3-way diverter valve and the Fast DHW function.
Does the Ferroli Omnia S 3.2 work with radiators or underfloor heating?
Yes. The Ferroli Omnia S 3.2 produces water up to 65 °C, so it is suitable for underfloor heating, fan coil units and radiators.
Can the Ferroli Omnia S 3.2 be combined with a boiler?
Yes. The Ferroli Omnia S 3.2 can work as the sole heat source for the system or be combined with other sources, such as a Ferroli boiler.
How is the Ferroli Omnia S 3.2 controlled?
The controls are on the unit, with a 2.8-inch graphic display and Capsense interface. With the optional Connect CRP, up to 8 thermostats and control via iOS and Android app can be managed.
Can the Ferroli Omnia S 3.2 be connected to photovoltaics?
Yes. The Ferroli Omnia S 3.2 has 2 digital Smart Grid inputs, EVU for photovoltaics and SG for the electricity grid, to improve self-consumption and energy bill costs.

Technical specifications

ModelOmnia S 3.2 10.0 kW
Product code0XHKASWA
Typesplit reversible air-to-water heat pump
Power supplysingle-phase
CompressorDC inverter
RefrigerantR32
Refrigerant GWP675
Electric booster3 kW (single-phase), 6 kW (three-phase)
Hot water producedup to 65 °C
Outdoor air sensorpre-fitted on the outdoor unit
DHW sensorsupplied, cylinder not supplied
3-way diverter valvestandard
Controls2.8-inch graphic display, Capsense, on the unit
ManagementModbus, optional Connect CRP, iOS and Android app with Connect CRP
Smart Grid inputs2 digital inputs (EVU and SG)