Split Air/Water Inverter Heat Pump Rhoss Electa-Ecos-B 9.5 kW MHAITI 110 + IUB 10 R-32 A+++
- 9,5 kW heating
- Class A+++

What size do I need?
For heat pumps and fan coils the right output is worked out by the installer on your home: heat loss, system, climate zone. Send us your measurements and we will reply with a quote.
Couldn't load pickup availability
Shipping and delivery
Shipping and delivery
Timing. With online payment, your order leaves with express courier and arrives within 1-2 working days. In remote areas and on islands, a few extra days may be needed: the estimated delivery date for your postcode is shown under “When it arrives”.
Costs. For orders under €80, shipping costs €8. Delivery to your floor is available for an additional charge.
Availability. Each product shows whether it is in stock, whether only a few units are left, or whether it is sold out; for sold-out products, you can leave your email and we will let you know as soon as they are back in stock.
Your order. You can track it from your account. For any questions, you will find our contact details on the Contact page; all the terms are on the Shipping page.
Support before and after purchase
Support before and after purchase
For advice on choosing a product, a technical question or an order already placed, the Buytutto customer service team is available Monday to Friday, 9:00 am to 1:00 pm and 2:00 pm to 6:00 pm.
You can message us on WhatsApp using the button on this page, or use the contact details on the Contact page. For a product you have already received, open a request from the Support page.
Description
Rhoss Electa-Ecos-B MHAITI 110 + IUB 10 is the reversible two-section air/water heat pump, with MHAITI 110 outdoor unit and IUB 10 indoor unit, for heating and domestic hot water. It works with R-32 gas, has energy class A+++ and declares an SCOP 4.60 in the low-temperature application (35°C). It produces water up to 60°C, with 9.5 kW of heating capacity under test conditions.

Water up to 60°C and domestic hot water with outdoor air from -25°C to +45°C
The heat pump produces water up to 60°C. The 3-way valve of the indoor unit manages domestic hot water production, with rapid heating function and anti-legionella cycle with activation timer. Domestic hot water production is declared with outdoor air from -25°C to +45°C.
DC Inverter compressor with vapour injection and economiser
The MHAITI 110 outdoor unit fits a hermetic twin rotary DC Inverter compressor with vapour injection, with thermal protection and crankcase heater. The refrigeration circuit includes an economiser, and the expansion valve is electronic.
Heating performance: COP 4.59 with water at 30-35°C
With air at 7°C DB - 6°C WB and water at 30-35°C the heating capacity is 9.5 kW, with power input 2.07 kW and COP 4.59. With water at 40-45°C the heating capacity remains 9.5 kW, with power input 2.64 kW and COP 3.6.
Reversible cooling with EER up to 3.79
With air at 35°C DB and water at 23-18°C the cooling capacity is 8.5 kW, with power input 2.24 kW and EER 3.79. With water at 12-7°C the cooling capacity is 6.5 kW, with EER 2.86 and useful circulator pump head of 63 kPa.
IUB 10 indoor unit with EC circulator and 10 l expansion vessel
The IUB 10 indoor unit is for wall installation. The pumping group includes an EC circulator, automatic air vent, 3 bar safety valve, flow switch, 10 l expansion vessel, pressure gauge and water filter. The water-side exchanger is stainless steel plate type with anti-freeze heater, and the electric backup heater is on the system side.
Control with touch-screen panel, room thermostat and smartphone app
The microprocessor electronic control with touch-screen panel manages weekly and daily time bands, holiday mode, anti-freeze function, silent operation with timer and electrical power input limitation. As an alternative to the touch-screen, management with a room thermostat is possible. The iOS and Android app manages the unit from smartphone and tablet, and the RS485 interface communicates with Modbus RTU protocol.
MHAITI 110 outdoor unit with DC brushless fans and Golden Fin coil
The finned coil has copper tubes and aluminium-manganese fins with Golden Fin anti-corrosion treatment in epoxy resin and hydrophilic treatment. The axial fans have DC brushless motors with thermal protection and continuous speed control. The structure is zinc-plated and painted sheet steel RAL9002, with a condensate collection tray and base anti-freeze heater.
Frequently asked questions
Which units make up the Rhoss Electa-Ecos-B MHAITI 110 + IUB 10 heat pump?
At what water temperature does the Rhoss Electa-Ecos-B MHAITI 110 + IUB 10 operate?
Does the Rhoss Electa-Ecos-B MHAITI 110 + IUB 10 also produce domestic hot water?
Can the Rhoss Electa-Ecos-B heat pump be controlled from a smartphone?
Which refrigerant gas does the Rhoss Electa-Ecos-B MHAITI 110 + IUB 10 use?
Are separate accessories needed to install the Rhoss Electa-Ecos-B MHAITI 110 + IUB 10?
Technical specifications
| Model and codes | |
| Brand | Rhoss |
| Model | Electa-Ecos-B |
| Indoor unit code | IUB 10 (EESB1IU002) |
| Outdoor unit code | MHAITI 110 (EES01OU004) |
| First start-up | not included, optional, carried out by authorised Rhoss SPA personnel |
| Seasonal heating performance, low temperature (35°C) | |
| Pdesignh (EN 14825) | 9 kW |
| SCOP (EN 14825) | 4.60 |
| Seasonal energy efficiency ηs | 181 % |
| Energy class | A+++ |
| Seasonal heating performance, medium temperature (55°C) | |
| Pdesignh (EN 14825) | 8 kW |
| SCOP (EN 14825) | 3.25 |
| Seasonal energy efficiency ηs | 127 % |
| Energy class | A++ |
| Heating performance | |
| Condition 1, air 7°C DB - 6°C WB, water 40-45°C, heating capacity | 9.5 kW |
| Condition 1, power input | 2.64 kW |
| Condition 1, COP | 3.6 |
| Condition 2, air 7°C DB - 6°C WB, water 30-35°C, heating capacity | 9.5 kW |
| Condition 2, power input | 2.07 kW |
| Condition 2, COP | 4.59 |
| Cooling performance | |
| Condition 3, air 35°C DB, water 12-7°C, cooling capacity | 6.5 kW |
| Condition 3, power input | 2.27 kW |
| Condition 3, EER | 2.86 |
| Condition 3, useful circulator pump head | 63 kPa |
| Condition 4, air 35°C DB, water 23-18°C, cooling capacity | 8.5 kW |
| Condition 4, power input | 2.24 kW |
| Condition 4, EER | 3.79 |
| Noise, power supply and lines | |
| Outdoor unit sound pressure | 42 dB(A) at 5 m in open field |
| Indoor unit electric heater | 2 x 3.0 n. x kW |
| Power supply | 230-1-50 V-ph-Hz |
| Max length / height difference of refrigerant lines | 25 / 15 m |
| Dimensions and weight | |
| MHAITI outdoor unit, width | 980 mm |
| MHAITI outdoor unit, height | 788 mm |
| MHAITI outdoor unit, depth | 427 mm |
| MHAITI outdoor unit, weight | 82 kg |
| IUB indoor unit, width | 460 mm |
| IUB indoor unit, height | 860 mm |
| IUB indoor unit, depth | 315 mm |
| IUB indoor unit, empty weight | 62 kg |
| Accessories | |
| Optional accessories supplied separately | KSA, rubber anti-vibration mounts |
| Optional accessories supplied separately | KPRE, cabling for RS485 serial connection to the touch-screen panel |
Data refer to Average climatic conditions according to EN 14825. Energy classification according to Regulations (EU) No 811/2013 and No 813/2013. Performance declared according to EN 14511.