Rhoss
Split Air/Water Inverter Heat Pump Rhoss Electa-Ecos-B 4 kW MHAITI 104 + IUB 06 R-32 A+++
- 4 kW heating
- Class A+++

What size do I need?
For heat pumps and fan coils the right output is worked out by the installer on your home: heat loss, system, climate zone. Send us your measurements and we will reply with a quote.
Couldn't load pickup availability
Shipping and delivery
Shipping and delivery
Timing. With online payment, your order leaves with express courier and arrives within 1-2 working days. In remote areas and on islands, a few extra days may be needed: the estimated delivery date for your postcode is shown under “When it arrives”.
Costs. For orders under €80, shipping costs €8. Delivery to your floor is available for an additional charge.
Availability. Each product shows whether it is in stock, whether only a few units are left, or whether it is sold out; for sold-out products, you can leave your email and we will let you know as soon as they are back in stock.
Your order. You can track it from your account. For any questions, you will find our contact details on the Contact page; all the terms are on the Shipping page.
Support before and after purchase
Support before and after purchase
For advice on choosing a product, a technical question or an order already placed, the Buytutto customer service team is available Monday to Friday, 9:00 am to 1:00 pm and 2:00 pm to 6:00 pm.
You can message us on WhatsApp using the button on this page, or use the contact details on the Contact page. For a product you have already received, open a request from the Support page.
Description
Rhoss Electa-Ecos-B 4 kW air-to-water heat pump is a reversible two-section system, with outdoor unit MHAITI 104 and indoor unit IUB 06, for heating, cooling and domestic hot water using R-32 gas. The deciding factors are the COP 5.13 with water at 30-35 °C, the heating capacity of 4 kW and the class A+++ at low temperature (35 °C), together with water produced up to 60 °C.
Two-section system: outdoor unit MHAITI 104 and indoor unit IUB 06
The outdoor unit MHAITI 104 (code EES01OU001) connects to the indoor unit IUB 06 (code EESB1IU001), which can be wall-mounted. The communication cable between the two units is included, and the refrigerant lines allow a maximum length of 20 m with a maximum height difference of 15 m.

DC Inverter compressor with vapour injection
The hermetic twin rotary DC Inverter compressor with vapour injection is fitted with thermal protection and a crankcase heater. The refrigerant circuit includes an economiser and an electronic expansion valve.
COP 5.13 with water at 30-35 °C in heating
With outdoor air at 7 °C dry bulb and 6 °C wet bulb, the heating capacity is 4 kW with water at 30-35 °C, with power input of 0.78 kW and COP 5.13. With water at 40-45 °C the heating capacity remains 4 kW, with 1.02 kW absorbed and COP 3.92.
Seasonal efficiency: SCOP 4.66 at 35 °C
At low temperature (35 °C) the SCOP is 4.66, the seasonal efficiency ηs is 184 % and the energy class is A+++. At medium temperature (55 °C) the SCOP is 3.27, ηs 128 % and the class A++. Pdesignh is 5 kW in both applications, according to EN 14825.
Cooling with EER up to 4.63
With air at 35 °C dry bulb and water at 12-7 °C the cooling capacity is 3.2 kW, with EER 3.42 and 0.94 kW absorbed. With water at 23-18 °C the cooling capacity rises to 3.8 kW, with EER 4.63 and 0.82 kW absorbed. The useful circulator head is 76 kPa.
Domestic hot water up to 60 °C with 3-way valve
The water produced reaches up to 60 °C, and domestic hot water production works with outdoor air from -25 °C to +45 °C. The 3-way valve manages domestic hot water, with a rapid heating function and an anti-legionella cycle with activation timer. An electric backup heater on the system side and a 20 m domestic hot water storage probe complete the equipment.
Touch-screen, thermostat and smartphone app control
The touch-screen panel manages the heat pump and the system with weekly and daily time bands, holiday mode, anti-freeze function and silent operation with timer. As an alternative to the touch-screen, a room thermostat can be used, and the unit can also be activated via a remote external ON/OFF contact. The iOS and Android app manages the unit from smartphone and tablet.
Complete pumping unit in the indoor unit
The indoor unit IUB 06 includes an EC circulator, automatic air vent valve, 3 bar safety valve, flow switch, 10 litre expansion vessel, pressure gauge and water filter. The structure is made of painted zinc-coated sheet steel, and the water-side heat exchanger is an insulated stainless steel plate type, with an anti-freeze heater.
Outdoor unit with 37 dB(A) sound pressure
The outdoor unit MHAITI 104 has a sound pressure of 37 dB(A) measured at 5 m in open field. The air-side heat exchanger is a finned coil with Golden Fin epoxy resin treatment, and the axial fan has DC brushless motors.
Optional first start-up, not included
The first start-up is optional and not included in the supply. The service is carried out by personnel authorised by Rhoss SPA.
Frequently asked questions
Which refrigerant gas does the Rhoss Electa-Ecos-B 4 kW use?
What COP does the Rhoss Electa-Ecos-B 4 kW have in heating?
How noisy is the MHAITI 104 outdoor unit?
Does the Rhoss Electa-Ecos-B 4 kW produce domestic hot water?
Can the Rhoss Electa-Ecos-B 4 kW be controlled from a smartphone?
What is the maximum length of the refrigerant lines in the Electa-Ecos-B system?
Technical specifications
| Model and codes | |
| Model | Rhoss Electa-Ecos-B MHAITI 104 + IUB 06 R-32 A+++ |
| Indoor unit | IUB 06 (EESB1IU001) |
| Outdoor unit | MHAITI 104 (EES01OU001) |
| First start-up | not included, optional |
| Heating power and performance | |
| Heating capacity with water 40-45 °C (air 7 °C DB - 6 °C WB) | 4 kW |
| Power input with water 40-45 °C | 1.02 kW |
| COP with water 40-45 °C | 3.92 |
| Heating capacity with water 30-35 °C (air 7 °C DB - 6 °C WB) | 4 kW |
| Power input with water 30-35 °C | 0.78 kW |
| COP with water 30-35 °C | 5.13 |
| Cooling power and performance | |
| Cooling capacity with water 12-7 °C (air 35 °C DB) | 3.2 kW |
| Power input with water 12-7 °C | 0.94 kW |
| EER with water 12-7 °C | 3.42 |
| Cooling capacity with water 23-18 °C (air 35 °C DB) | 3.8 kW |
| Power input with water 23-18 °C | 0.82 kW |
| EER with water 23-18 °C | 4.63 |
| Useful circulator head | 76 kPa |
| Seasonal energy efficiency | |
| Low temperature application (35 °C) | Pdesignh 5 kW, SCOP 4.66, ηs 184 %, class A+++ |
| Medium temperature application (55 °C) | Pdesignh 5 kW, SCOP 3.27, ηs 128 %, class A++ |
| Seasonal data standard | EN 14825, Average climate conditions |
| Performance standard | EN 14511 |
| Energy labelling | Regulations (EU) No 811/2013 and No 813/2013 |
| Noise | |
| Outdoor unit sound pressure | 37 dB(A) at 5 m in open field |
| Installation and connections | |
| Indoor unit electric backup heater | 2 x 1.5 n. x kW |
| Power supply | 230-1-50 V-ph-Hz |
| Max refrigerant line length / height difference | 20 / 15 m |
| Dimensions and weight | |
| MHAITI outdoor unit, width | 975 mm |
| MHAITI outdoor unit, height | 702 mm |
| MHAITI outdoor unit, depth | 396 mm |
| MHAITI outdoor unit, weight | 55 kg |
| Indoor unit, width | 460 mm |
| Indoor unit, height | 860 mm |
| Indoor unit, depth | 315 mm |
| Indoor unit, empty weight | 62 kg |
| Functions and equipment | |
| Water production temperature | up to 60 °C |
| Domestic hot water | from -25 °C up to +45 °C outdoor air |
| Functions | touch-screen, iOS and Android app, RS485 Modbus RTU interface, room thermostat, remote ON/OFF |
| Accessories supplied separately | KSA rubber anti-vibration mounts, KPRE RS485 serial connection wiring |
| Materials and components | |
| Refrigerant gas | R-32 |
| Compressor | hermetic twin rotary DC Inverter with vapour injection |
| Outdoor unit frame | zinc-coated steel sheet painted RAL9002 |