Skip to content

Description

Rhoss BRIO-I Slim IXP 10 is a recessed inverter fan coil unit for ceiling or wall installation. It delivers 0.98 kW maximum cooling capacity, 162 m³/h maximum air flow and 23-41 dB(A) sound pressure. The IXP version is a 2-pipe unit with a single main coil and included recessed casing.

Cooling capacity up to 0.98 kW

In cooling mode, the total cooling capacity of the Rhoss BRIO-I Slim IXP 10 is MAX 0.98 kW, MED 0.75 kW and MIN 0.38 kW, with air at 27 °C and water at 7/12 °C.

Heating up to 2.27 kW with water at 70/60 °C

In heating mode, the heating capacity depends on the water temperature. With water at 45/40 °C it reaches 1.13 kW at MAX; with water at 50 °C, 1.39 kW at MAX; with water at 70/60 °C, 2.27 kW at MAX, with 1.63 kW at MED and 1.16 kW at MIN.

Quiet: 23-41 dB(A) for a 100 m³ room

The BRIO-I Slim IXP 10 has a sound pressure of 41 dB(A) at MAX, 33 dB(A) at MED and 23 dB(A) at MIN, measured for a 100 m³ room. The sound power at MAX is 50 dB(A). Air flow is 162 m³/h at MAX, 113 m³/h at MED and 55 m³/h at MIN.

Continuously variable EC motor, consumption from 7 to 11 W

The cross-flow fan is driven by a continuously variable-speed EC electronic motor. The Rhoss BRIO-I Slim IXP 10 consumes 11 W at MAX, 9 W at MED and 7 W at MIN, and adjusts its output to the actual needs of the room.

Slim recessed design

The design is slim and linear. The Rhoss BRIO-I Slim IXP 10 is installed in a ceiling or on a wall, with a depth of 149 mm and a height of 579 mm in the 2-pipe version.

White recessed fan coil unit on a light wall, with supply grille at the top and return grille at the bottom

Radiant heating in versions with the radiant function

In some versions of the BRIO-I Slim series, the radiant function is available: heat is transferred from the exchanger to a plate and released through the front panel, which warms up in heating mode.

Recessed casing and decorative panels

The recessed installation casing is included only for 2-pipe systems. For the Rhoss BRIO-I Slim IXP 10, you can choose either the wall decorative panel for the casing or the ceiling decorative panel for the casing, both in matt white RAL 9003.

Finned coil with ¾" Eurokonus connections

The exchanger is a finned coil with left-hand ¾" Eurokonus connections. The right-hand connections are made using the accessory supplied separately. The galvanised sheet steel structure includes a vertical, additional and horizontal gravity-drain condensate tray, a regenerable filter and mounting brackets.

Frequently asked questions

Where is the Rhoss BRIO-I Slim IXP 10 installed?
The Rhoss BRIO-I Slim IXP 10 is a recessed fan coil unit that can be installed in a ceiling or on a wall, with recessed casing included for 2-pipe systems.
How noisy is the Rhoss BRIO-I Slim IXP 10?
The Rhoss BRIO-I Slim IXP 10 has a sound pressure of 23 dB(A) at MIN, 33 dB(A) at MED and 41 dB(A) at MAX, for a 100 m³ room. The sound power at MAX is 50 dB(A).
Does the Rhoss BRIO-I Slim IXP 10 have a radiant function?
The radiant function is only available in some versions of the BRIO-I Slim series: in heating mode, heat is transferred from the exchanger to a plate and released through the front panel.
What are the dimensions and weight of the Rhoss BRIO-I Slim IXP 10?
The Rhoss BRIO-I Slim IXP 10 measures 723 mm wide, 149 mm deep and 579 mm high in the 2-pipe version, or 639 mm in the 4-pipe version. It weighs 17 kg in the 2T version and 18 kg in the 4T.
How are the connections of the Rhoss BRIO-I Slim IXP 10 made?
The Rhoss BRIO-I Slim IXP 10 has left-hand ¾" Eurokonus connections on the finned coil. The right-hand connections are made using the accessory supplied separately.
What motor does the Rhoss BRIO-I Slim IXP 10 use?
The Rhoss BRIO-I Slim IXP 10 uses a cross-flow fan with a continuously variable-speed EC electronic motor, consuming 7 W at MIN and 11 W at MAX.

Technical specifications

Model and codes
ModelRHOSS Fan Coil Inverter Unit BRIO-I SLIM IXP 10 - Recessed for ceiling/wall with casing
Typehorizontal/vertical recessed unit for ceiling or wall
Version2T, single main coil
Power and performance
Total cooling capacity (air 27 °C, water 7/12 °C)MAX 0.98 kW / MED 0.75 kW / MIN 0.38 kW
Heating capacity (water 45/40 °C)MAX 1.13 kW / MED 0.81 kW / MIN 0.57 kW
Heating capacity (water 50 °C)MAX 1.39 kW / MED 1.0 kW / MIN 0.7 kW
Heating capacity (water 70/60 °C)MAX 2.27 kW / MED 1.63 kW / MIN 1.16 kW
Air flowMAX 162 m³/h / MED 113 m³/h / MIN 55 m³/h
Noise
Sound pressure (for a 100 m³ room)MAX 41 dB(A) / MED 33 dB(A) / MIN 23 dB(A)
Sound power MAX50 dB(A)
Electrical data
Power supply230V - 1ph - 50Hz
Power consumptionMAX 11 W / MED 9 W / MIN 7 W
Dimensions and weight
Width723 mm
Height579 mm (2T) / 639 mm (4T)
Depth149 mm
Weight17 kg (2T) / 18 kg (4T)
Installation and supply
Exchanger connectionsleft-hand ¾" Eurokonus; right-hand with accessory supplied separately
Structuregalvanised sheet steel with condensate tray, regenerable filter and mounting brackets
Functionscross-flow fan with EC motor, radiant function in some versions of the series
Casingincluded for recessed installation (2-pipe systems only)
Decorative panels for the casingwall (KPCASEV) or ceiling (KPCASEO), matt white RAL 9003