Skip to content

Description

The Panasonic Dual Split Inverter floor-standing air conditioner with CU-2Z50TBE outdoor unit is a dual split air conditioner: two floor-standing indoor units, CS-Z25UFEAW and CS-Z50UFEAW, connected to a single outdoor unit. Output of 9000+18000 BTU, R-32 refrigerant, 5.00 kW rated cooling, and heating with outdoor temperatures down to -15 °C.

Two units of a Panasonic air conditioner: a white floor-standing indoor unit

Two floor-standing indoor units with a single outdoor unit

The CS-Z25UFEAW and CS-Z50UFEAW indoor units are Inverter type and measure 600 x 750 x 207 mm. They blend discreetly into any room. The outdoor unit is the CU-2Z50TBE, with a net weight of 39 kg.

Dual air outlet: cool air upwards, warm air downwards

The Panasonic Dual Split Inverter has a dual air-conditioned outlet: cool air goes upwards and warm air downwards. This improves comfort and makes the room temperature more even.

Heating with outdoor temperatures down to -15 °C

In heating the CU-2Z50TBE works with outdoor temperatures from -15 °C to +24 °C. The theoretical heating capacity Pdesign at -10 °C is 4.20 kW.

Installation on existing R22 pipework

The system can be installed using the R22 gas pipework already in place. Connections are 1/4 (6.35 mm) on the liquid side and 3/8 (9.52 mm) on the gas side, with a height difference of 10 m between indoor and outdoor unit.

Very high efficiency with low consumption

The average annual ErP consumption of the CU-2Z50TBE is 206 kWh/a in cooling and 1278 kWh/a in heating. The Powerful power level quickly reaches the set temperature.

Panasonic: over 30 years of experience and compressor warranted for five years

Panasonic has over 30 years of experience and customers in over 120 countries in the heating and cooling sector. The outdoor unit compressor of the Residential, Semi-industrial, Aquarea and Industrial air conditioner series (excluding gas and DHW VRF systems) is warranted for five years from the date of purchase, if it is the original compressor fitted at the Panasonic factory.

Technical table of the outdoor units of the Free Multi Z system with R32 refrigerant, showing capacity and consumption data

Frequently asked questions

What does dual split mean on this Panasonic?
The Panasonic CU-2Z50TBE is the outdoor unit to which two floor-standing indoor units connect, the CS-Z25UFEAW and CS-Z50UFEAW, with a 9000+18000 BTU output.
Can it be installed on existing R22 pipework?
Yes: the Panasonic Dual Split Inverter can be installed using the R22 gas pipework already in place.
Up to what outdoor temperature does the Panasonic CU-2Z50TBE heat?
In heating the Panasonic CU-2Z50TBE works with outdoor temperatures from -15 °C to +24 °C, and the description indicates heating performance even with outdoor temperatures down to -15 °C.
What is the cooling capacity of the Panasonic CU-2Z50TBE?
The rated cooling capacity of the Panasonic CU-2Z50TBE is 5.00 kW, with a range from 1.50 to 5.40 kW.
How much energy does the Panasonic Dual Split Inverter use per year?
The average annual ErP consumption of the Panasonic CU-2Z50TBE is 206 kWh/a in cooling and 1278 kWh/a in heating.
What connection pipes are needed for the indoor units?
The Panasonic CU-2Z50TBE has a 1/4 (6.35 mm) liquid-side connection and a 3/8 (9.52 mm) gas-side connection, with a maximum height difference of 10 m between indoor and outdoor unit.

Technical specifications

Model and codes
Indoor unit 1CS-Z25UFEAW
Indoor unit 2CS-Z50UFEAW
Outdoor unitCU-2Z50TBE
Indoor unit typeInverter
Refrigerant gasR-32
Output and performance
Indoor unit output (BTU)9000+18000
Rated cooling capacity (min - max) (kW)5.00 (1.50-5.40)
Theoretical cooling capacity Pdesign (kW)5.00
Rated outdoor unit capacity (min - max) (kW)3.20 ~ 7.70
Theoretical heating capacity Pdesign at -10 °C (kW)4.20
Outdoor operating temperature range in cooling (°C)-10 ~ +46
Outdoor operating temperature range in heating (°C)-15 ~ +24
Energy efficiency
Rated cooling power input (min - max) (kW)1.18 (0.25-1.49)
Average annual cooling consumption ErP (kWh/a)206
Rated heating power input (min - max) (kW)1.21 (0.21-1.80)
Average annual heating consumption ErP (kWh/a)1278
Rated cooling current draw (A)5.35
Rated heating current draw (A)5.50
Dimensions and weight
Indoor unit dimensions H x W x D (mm)600 x 750 x 207
Net weight of outdoor unit (kg)39
Installation and connections
Power supply voltage (V)230
Power supply wiring (mm²)2.5
Liquid-side connection pipes (inches (mm))1/4 (6.35)
Gas-side connection pipes (inches (mm))3/8 (9.52)
Total connection pipe length (m)6 ~ 30
Single-unit pipe length (m)3 ~ 20
Height difference indoor/outdoor (m)10
Additional refrigerant charge (g/m)15
Features and equipment
Featuresdual air-conditioned outlet, Powerful power level, installation on existing R22 pipework