Beretta
Beretta Open-Flue Boiler Natural Gas Mynute 24 Cai LX 24 kW - Code 20151436
- 24,05 kW heating
- 14 litres per minute
- Natural gas

Couldn't load pickup availability
Shipping and delivery
Shipping and delivery
Timing. With online payment, your order leaves with express courier and arrives within 1-2 working days. In remote areas and on islands, a few extra days may be needed: the estimated delivery date for your postcode is shown under “When it arrives”.
Costs. For orders under €80, shipping costs €8. Delivery to your floor is available for an additional charge.
Availability. Each product shows whether it is in stock, whether only a few units are left, or whether it is sold out; for sold-out products, you can leave your email and we will let you know as soon as they are back in stock.
Your order. You can track it from your account. For any questions, you will find our contact details on the Contact page; all the terms are on the Shipping page.
Support before and after purchase
Support before and after purchase
For advice on choosing a product, a technical question or an order already placed, the Buytutto customer service team is available Monday to Friday, 9:00 am to 1:00 pm and 2:00 pm to 6:00 pm.
You can message us on WhatsApp using the button on this page, or use the contact details on the Contact page. For a product you have already received, open a request from the Support page.
Description
Beretta Mynute 24 Cai LX (Code 20151436) is a wall-hung, instantaneous combination boiler with open flue, natural draught and natural gas supply, for heating and domestic hot water. It delivers 24.05 kW of nominal heat output (80-60 °C) and 14 litres/min of hot water at Δt 25 °C, with a useful efficiency of 93.2% and NOx emissions class 5. It is designed to make it easy to replace existing wall-mounted boilers.

Micro-flame burner with low NOx emissions
The eco burner is atmospheric, air-cooled and fitted with a larger number of nozzles, which allows the gas and air to be premixed. Combustion takes place at lower temperatures than in a traditional burner. The flame spreads across a surface only a few millimetres high, known as a micro-flame. The tube running through the burner, carrying the system's return water, helps to cool it.
Standard low-consumption circulator
The circulator on the Mynute 24 Cai LX is standard and low-consumption, with EEI ≤0.20.
Digital display and control provisions
The digital display on the Mynute 24 Cai LX is simple and intuitive. The boiler is prepared for weather-compensated temperature control, with an optional outdoor sensor, and for connection to the Comfort BeSMART control (code 20143539).
Frequently asked questions
Is the Beretta Mynute 24 Cai LX an open-flue boiler?
How much domestic hot water does the Beretta Mynute 24 Cai LX produce?
Which flue pipes does the Beretta Mynute 24 Cai LX accept?
Is the Beretta Mynute 24 Cai LX suitable for replacing an existing wall-mounted boiler?
Can the Beretta Mynute 24 Cai LX be connected to a control unit?
Technical specifications
| Model and codes | |
| Model | Mynute 24 Cai LX |
| Product code | 20151436 |
| Type | open-flue boiler, instantaneous combination, natural draught |
| Fuel | natural gas |
| Power and performance | |
| Nominal heat input | 25.80 kW |
| Nominal heat output (80-60 °C) | 24.05 kW |
| Reduced heat output (80-60 °C) | 11.28 kW |
| Reduced heat input | 12.5 kW |
| Electrical power | 115 W |
| Supply voltage / frequency | 230 V / 50 Hz |
| Electrical protection rating | IPX5D |
| Efficiency and emissions | |
| Useful efficiency at Pn max (80-60 °C) | 93.2% |
| Useful efficiency at 30% of Pn (47 °C return) | 91.8% |
| NOx according to UNI EN 483 | class 5 |
| Circulator | EEI ≤0.20, standard |
| Heating | |
| Maximum heating pressure | 3 bar |
| Maximum heating temperature | 90 °C |
| Heating temperature setting range | 40 / 80 °C |
| Pump head available for the system | 275 mbar at a flow rate of 1000 litres/h |
| Expansion vessel capacity | 9 litres |
| Domestic hot water | |
| Maximum domestic water pressure | 6 bar |
| Minimum domestic water pressure | 0.15 bar |
| Hot water quantity at Δt 25 °C | 14 litres/min |
| Minimum domestic water flow rate | 2 litres/min |
| Domestic hot water temperature setting range | 37 - 60 °C |
| Flue discharge and air intake | |
| Coaxial pipe diameter | 60-100 mm |
| Maximum coaxial pipe length | 2.5 m |
| Coaxial pipe loss per 90° / 45° bend | 1.5 m / 1 m |
| Separate pipe diameter | 80 + 80 mm |
| Maximum separate pipe length | 14 + 14 m |
| Separate pipe loss per 90° / 45° bend | 1.7 m / 1.2 m |
| Dimensions and weight | |
| Boiler dimensions (H x W x D) | 780 x 400 x 338 mm |
| Weight | 35 kg |
| Equipment | |
| Features | simple and intuitive digital display; eco burner with low NOx emissions |
| Outdoor sensor for weather-compensated temperature control | optional |
| Comfort BeSMART control | provision, code 20143539 |
| Hydraulic fittings, gas and domestic water taps | optional |