Ariston NIMBUS POCKET M NET 120 (code 3301874) is a single-phase monobloc inverter heat pump using R32 refrigerant, which heats and cools the space. Heating efficiency is class A+++ at 35 °C and A++ at 55 °C, with COP 4.90 with outdoor air at 7 °C and water at 30/35 °C. The controller is included; the hydraulic module is not included.

Heating: 12.00 kW with outdoor air at 7 °C

With outdoor air at 7 °C and water at 30/35 °C, the nominal heating capacity is 12.00 kW, with 2.45 kW absorbed and COP 4.90. With water at 40/45 °C, the heating capacity drops to 8.20 kW, with 2.00 kW absorbed and COP 4.10. With outdoor air at -7 °C and water at 30/35 °C, the nominal heating capacity is 9.51 kW, with 2.97 kW absorbed and COP 3.20.

Stable performance at any outdoor temperature

Energy Manager manages the hardware and software of the entire system and ensures stable performance at any outdoor temperature, with the lowest noise level in its category.

Cooling with EER up to 5.08

In cooling mode with outdoor air at 35 °C and water at 18/23 °C, the nominal cooling capacity is 10.74 kW, with 2.11 kW absorbed and EER 5.08. With water at 7/12 °C, the nominal cooling capacity is 9.05 kW, with 2.87 kW absorbed and EER 3.15.

Smartphone control with Ariston NET app and Sensys NET

The Ariston NET app lets you control heating, cooling and hot water directly from your smartphone, with assistance 24 hours a day. The integrated Sensys NET system manages multiple zones and can integrate solar thermal and photovoltaic energy and auxiliary generators.

White monobloc outdoor heat pump with grille fan, wall-mounted control with display and external sensor

Hydraulic module excluded for a compact footprint

The POCKET model does not include the hydraulic module, for the smallest possible footprint.

Components tested before delivery

Each component is developed to ensure long-lasting performance and high efficiency, and every Ariston product is tested for quality, efficiency and safety before delivery. The manufacturer describes resistant materials and components designed to operate in extreme conditions, and describes Ariston heat pumps as completely safe.

Frequently asked questions

Which refrigerant gas does the Ariston NIMBUS POCKET M NET 120 use?
The Ariston NIMBUS POCKET M NET 120 heat pump uses R32 refrigerant.
Does the Ariston NIMBUS POCKET M NET 120 need a hydraulic module?
The POCKET model does not include the hydraulic module, because the Ariston NIMBUS POCKET M NET 120 is designed for the smallest possible footprint.
What heating capacity does the Ariston NIMBUS POCKET M NET 120 deliver in very cold weather?
With outdoor air at -7 °C and water at 30/35 °C, the Ariston NIMBUS POCKET M NET 120 delivers a nominal heating capacity of 9.51 kW, with COP 3.20.
What electrical supply does the Ariston NIMBUS POCKET M NET 120 require?
The Ariston NIMBUS POCKET M NET 120 is powered at 220~240 V, 50 Hz, single-phase.
Can the Ariston NIMBUS POCKET M NET 120 be controlled from a smartphone?
Yes, the Ariston NET app controls heating, cooling and hot water of the Ariston NIMBUS POCKET M NET 120 from your smartphone, with assistance 24 hours a day.
Is the controller included with the Ariston NIMBUS POCKET M NET 120?
Yes, the controller is included in the supply of the Ariston NIMBUS POCKET M NET 120.

Technical specifications

Model and codes
BrandAriston
ModelNIMBUS POCKET M NET 120
Code3301874
Typemonobloc inverter heat pump
Energy efficiency
Energy class for heating at 35 °CA+++
Energy class for heating at 55 °CA++
Heating
Nominal heating capacity, outdoor air -7 °C and water 30/35 °C9.51 kW
Electrical power absorbed, outdoor air -7 °C and water 30/35 °C2.97 kW
COP, outdoor air -7 °C and water 30/35 °C3.20
Nominal heating capacity, outdoor air 7 °C and water 30/35 °C12.00 kW
Electrical power absorbed, outdoor air 7 °C and water 30/35 °C2.45 kW
COP, outdoor air 7 °C and water 30/35 °C4.90
Nominal heating capacity, outdoor air 7 °C and water 40/45 °C8.20 kW
Electrical power absorbed, outdoor air 7 °C and water 40/45 °C2.00 kW
COP, outdoor air 7 °C and water 40/45 °C4.10
Cooling
Nominal cooling capacity, outdoor air 35 °C and water 7/12 °C9.05 kW
Electrical power absorbed, outdoor air 35 °C and water 7/12 °C2.87 kW
EER, outdoor air 35 °C and water 7/12 °C3.15
Nominal cooling capacity, outdoor air 35 °C and water 18/23 °C10.74 kW
Electrical power absorbed, outdoor air 35 °C and water 18/23 °C2.11 kW
EER, outdoor air 35 °C and water 18/23 °C5.08
Power supply and refrigerant
Power supply (V, Hz, Ø)220~240/50/1
Refrigerant gasR32
Dimensions and weight
Dimensions (W x H x D)1016 x 1506 x 374 mm
Empty weight1241.0 kg
Equipment and control
Controllerincluded
Hydraulic modulenot included
First start-upfree
Control appAriston NET (heating, cooling, hot water)
Integrated systemSensys NET (multiple zones, solar thermal and photovoltaic, auxiliary generators)