Beretta
Hydronic Heat Pump Beretta Model HYDRO UNIT M 008 Single-Phase R-32 Air-Water Controller Not Included
Hydronic Heat Pump Beretta Model HYDRO UNIT M 008 Single-Phase R-32 Air-Water Controller Not Included

What size do I need?
For heat pumps and fan coils the right output is worked out by the installer on your home: heat loss, system, climate zone. Send us your measurements and we will reply with a quote.
Couldn't load pickup availability
Shipping and delivery
Shipping and delivery
Timing. With online payment, your order leaves with express courier and arrives within 1-2 working days. In remote areas and on islands, a few extra days may be needed: the estimated delivery date for your postcode is shown under “When it arrives”.
Costs. For orders under €80, shipping costs €8. Delivery to your floor is available for an additional charge.
Availability. Each product shows whether it is in stock, whether only a few units are left, or whether it is sold out; for sold-out products, you can leave your email and we will let you know as soon as they are back in stock.
Your order. You can track it from your account. For any questions, you will find our contact details on the Contact page; all the terms are on the Shipping page.
Support before and after purchase
Support before and after purchase
For advice on choosing a product, a technical question or an order already placed, the Buytutto customer service team is available Monday to Friday, 9:00 am to 1:00 pm and 2:00 pm to 6:00 pm.
You can message us on WhatsApp using the button on this page, or use the contact details on the Contact page. For a product you have already received, open a request from the Support page.
Description
Beretta HYDRO UNIT M 008 is a single-phase air-to-water hydronic heat pump with R-32 gas, for heating, cooling and domestic hot water. It delivers 8.40 kW of useful output in heating with water at 35 °C and 8.30 kW of useful output in cooling with water at 18 °C. It is an outdoor-installed monoblock that connects to fan coil units, underfloor heating, low-temperature radiators and domestic hot water tanks.

COP 5.15 at 35 °C and energy class A+++ up to 35 °C
The heating COP is 5.15 with water set to 35 °C, 3.85 at 45 °C and 3.18 at 55 °C. The heating energy class is A+++ with water at 35 °C and A++ with water at 55 °C. In cooling mode the EER is 5.05 with water at 18 °C and 3.35 with water at 7 °C.
HP KEYMARK certified design
The design of the Beretta HYDRO UNIT M meets the requirements of the voluntary European HP KEYMARK certification.
R-32 gas with sealed circuit
R-32 has a lower Global Warming Potential than traditional gases. The new sealed circuit for fluorinated gases, the reduced refrigerant charge volumes and lower CO2 emissions increase the environmental sustainability of the unit.
Programmable Quiet Mode
The low noise level is ensured by construction features and can be further reduced with the Quiet Mode, which can be programmed by the customer.
Anti-freeze function for the entire hydraulic circuit
The ANTI-FREEZE function, which can be programmed by the customer, activates automatically when the water temperature in the system drops below a preset value, protecting the entire hydraulic circuit.
Inverter board and DC twin rotary compressor
The inverter control board maximises output under critical load conditions and ensures stability and efficiency at partial loads. The twin rotary compressor, a DC double rotary compressor, precisely adjusts motor speed to deliver the power needed for the actual load. The Operating Parameters board monitors ambient and water temperature to activate the various components. The electronic expansion valve optimises the flow of refrigerant in every situation.
AISI 316 stainless steel exchanger and hydronic module
The AISI 316 stainless steel plate heat exchanger is protected by closed-cell anti-condensation insulation and offers high heat exchange efficiency. The hydronic module includes a low-consumption circulator pump, an 8-litre expansion vessel, an automatic air vent and a safety valve.
Large-surface fan and coil
The fan has a specially designed blade that optimises the airflow surface, improving efficiency and reducing fan noise. The heat exchange coil has an extended surface with aluminium fins.
Hydronic kit for outdoor installation
The heat pump is designed for outdoor installation. The hydronic kit supplied with the monoblock contains all the essential components, and its ability to respond quickly to the real needs of the spaces served makes the unit flexible.

Backup heater as an accessory
The backup heater, available as an accessory, increases heating capacity with cold outdoor temperatures. It acts as a reserve in case of an operating fault and protects the external water pipes from frost during winter.
HYDRO UNIT M range from 4 kW to 16 kW
The HYDRO UNIT M series includes ten models with outputs from 4 kW to 16 kW.
Frequently asked questions
What refrigerant gas does the Beretta HYDRO UNIT M 008 use?
What COP does the Beretta HYDRO UNIT M 008 have with water at 35 °C and 55 °C?
Is the backup heater included with the Beretta HYDRO UNIT M 008?
Which systems can the Beretta HYDRO UNIT M 008 be paired with?
Is the Beretta HYDRO UNIT M 008 quiet?
How does the Beretta HYDRO UNIT M 008 protect the system from frost?
Technical specifications
| Model and codes | |
| Model | HYDRO UNIT M 008 Single-phase |
| SKU code | HYDRO_UNIT_M008 |
| GTIN | 8018000405154 |
| Refrigerant gas | R-32 |
| Energy efficiency | |
| Heating energy class at 35 °C | A+++ |
| Heating energy class at 55 °C | A++ |
| Heating COP with water at 35 °C | 5.15 |
| Heating COP with water at 45 °C | 3.85 |
| Heating COP with water at 55 °C | 3.18 |
| Cooling EER with water at 7 °C | 3.35 |
| Cooling EER with water at 18 °C | 5.05 |
| Power and performance | |
| Useful heating output with water at 35 °C | 8.40 kW |
| Useful heating output with water at 45 °C | 8.10 kW |
| Useful heating output with water at 55 °C | 7.50 kW |
| Power input with water at 35 °C | 1.63 kW |
| Power input with water at 45 °C | 2.10 kW |
| Power input with water at 55 °C | 2.36 kW |
| Useful cooling output with water at 7 °C | 7.45 kW |
| Useful cooling output with water at 18 °C | 8.30 kW |
| Cooling power input with water at 7 °C | 2.22 kW |
| Cooling power input with water at 18 °C | 1.64 kW |
| Maximum power input | 0.043 kW |
| Hydronic circuit | |
| Maximum operating pressure of hydronic circuit | 3 bar |
| System expansion vessel | 8 litres |
| Dimensions and weight | |
| Dimensions (L x H x D) | 1295x945x526 mm |
| Empty weight | 121.0 kg |