Beretta
Hydronic Heat Pump Beretta Model HYDRO UNIT M 006 Single-Phase R-32 Air-Water Controller Not Included
Hydronic Heat Pump Beretta Model HYDRO UNIT M 006 Single-Phase R-32 Air-Water Controller Not Included

What size do I need?
For heat pumps and fan coils the right output is worked out by the installer on your home: heat loss, system, climate zone. Send us your measurements and we will reply with a quote.
Couldn't load pickup availability
Shipping and delivery
Shipping and delivery
Timing. With online payment, your order leaves with express courier and arrives within 1-2 working days. In remote areas and on islands, a few extra days may be needed: the estimated delivery date for your postcode is shown under “When it arrives”.
Costs. For orders under €80, shipping costs €8. Delivery to your floor is available for an additional charge.
Availability. Each product shows whether it is in stock, whether only a few units are left, or whether it is sold out; for sold-out products, you can leave your email and we will let you know as soon as they are back in stock.
Your order. You can track it from your account. For any questions, you will find our contact details on the Contact page; all the terms are on the Shipping page.
Support before and after purchase
Support before and after purchase
For advice on choosing a product, a technical question or an order already placed, the Buytutto customer service team is available Monday to Friday, 9:00 am to 1:00 pm and 2:00 pm to 6:00 pm.
You can message us on WhatsApp using the button on this page, or use the contact details on the Contact page. For a product you have already received, open a request from the Support page.
Description
Beretta HYDRO UNIT M 006 is a single-phase air-to-water hydronic heat pump with R-32 refrigerant, for heating, cooling and domestic hot water with storage tanks or solar kits. In heating mode it delivers 6.35 kW of useful output with water at 35 °C and a COP of 4.95, with energy class A+++ up to 35 °C. In cooling mode, useful output reaches 7.00 kW with water at 7 °C.

System combinations
The heat pump can be combined with fan coil units, underfloor heating, high-efficiency low-temperature radiators, domestic hot water tanks and solar kits, all supplied on site.
HYDRO UNIT M series: ten models from 4 to 16 kW
The HYDRO UNIT M series includes ten models with outputs from 4 kW to 16 kW, with a fast response to demand and reduced energy consumption. Class A+++ applies up to 35 °C and A++ up to 55 °C.
Twin rotary compressor and inverter board
The twin rotary compressor is a DC double rotary compressor. Together with the fan motor and the pump, it works with the Inverter System and precisely controls motor speed, delivering the power needed for the actual load and saving energy. The inverter control board maximises output under critical load conditions and ensures stability and efficiency at partial loads.
Electronic expansion valve and operating parameters board
The electronic expansion valve optimises the flow of refrigerant in every situation. The operating parameters control board constantly monitors ambient and water temperature to activate the various components and meet demand.
Special blade fan and aluminium coil
The fan has a specially designed blade that optimises the airflow surface, improves efficiency and reduces fan noise. The heat exchange coil has an extended surface and aluminium fins.
AISI 316 stainless steel plate heat exchanger
The AISI 316 stainless steel plate heat exchanger is protected by closed-cell anti-condensation insulation and offers high heat exchange efficiency.
Hydronic kit and hydronic module
The hydronic kit is supplied with the monoblock and contains all the essential components for installation. The hydronic module includes a low-consumption circulator pump, an 8-litre expansion vessel, an automatic air vent and a safety valve. The maximum operating pressure of the hydronic circuit is 3 bar.
Outdoor installation with anti-freeze function
The HYDRO UNIT M 006 is designed for outdoor installation. The anti-freeze function, which can be programmed by the customer, activates automatically when the water temperature in the system drops below a preset value, protecting the entire hydraulic circuit.

Quiet Mode
The low noise level comes from its construction features and can be further reduced with the Quiet Mode, which can be programmed by the customer.
Backup heater available as an accessory
The backup heater, available as an accessory, increases heating capacity when outdoor temperatures are cold. It also serves as a backup in case of an operating fault and as frost protection for the external water pipes during winter.
R-32 and HP KEYMARK certification
R-32 gas has a lower Global Warming Potential than traditional gases. The sealed circuit for fluorinated gases, the reduced refrigerant charge volumes and lower CO2 emissions increase the environmental sustainability of the HYDRO UNIT M. The design meets the requirements of the voluntary European HP KEYMARK certification.
Frequently asked questions
What systems is the Beretta HYDRO UNIT M 006 used for?
Does the Beretta HYDRO UNIT M 006 need to be installed outdoors?
Which refrigerant gas does the HYDRO UNIT M 006 use?
How quiet is the Beretta HYDRO UNIT M 006?
What is the backup heater of the HYDRO UNIT M 006 for?
What is the difference between a hydronic kit and a hydronic module?
Technical specifications
| Model and codes | |
| Model | HYDRO UNIT M 006 |
| Type | air-to-water hydronic heat pump, monoblock |
| Power supply | single-phase |
| Refrigerant | R-32 |
| Energy efficiency | |
| Heating energy class with water at 35 °C | A+++ |
| Heating energy class with water at 55 °C | A++ |
| Heating COP with water at 35 °C | 4.95 |
| Heating COP with water at 45 °C | 3.70 |
| Heating COP with water at 55 °C | 2.95 |
| Cooling EER with water at 7 °C | 3.00 |
| Cooling EER with water at 18 °C | 4.80 |
| Power and performance | |
| Useful heating output with water at 35 °C | 6.35 kW |
| Useful heating output with water at 45 °C | 6.30 kW |
| Useful heating output with water at 55 °C | 6.00 kW |
| Heating power input with water at 35 °C | 1.28 kW |
| Heating power input with water at 45 °C | 1.70 kW |
| Heating power input with water at 55 °C | 2.03 kW |
| Useful cooling output with water at 7 °C | 7.00 kW |
| Useful cooling output with water at 18 °C | 6.50 kW |
| Cooling power input with water at 7 °C | 2.33 kW |
| Cooling power input with water at 18 °C | 1.35 kW |
| Features | |
| Maximum operating pressure of hydronic circuit | 3 bar |
| Maximum power input | 0.043 kW |
| System expansion vessel | 8 litres |
| Certification | HP KEYMARK |
| Dimensions and weight | |
| Dimensions (L x H x D) | 1295x792x429 mm |
| Empty weight | 98.0 kg |