Fantini Cosmi
Heat Recovery Ventilator Fantini Cosmi UVR-HE HORIZONTAL/vertical 750 m³/h

Couldn't load pickup availability
Shipping and delivery
Shipping and delivery
Timing. With online payment, your order leaves with express courier and arrives within 1-2 working days. In remote areas and on islands, a few extra days may be needed: the estimated delivery date for your postcode is shown under “When it arrives”.
Costs. For orders under €80, shipping costs €8. Delivery to your floor is available for an additional charge.
Availability. Each product shows whether it is in stock, whether only a few units are left, or whether it is sold out; for sold-out products, you can leave your email and we will let you know as soon as they are back in stock.
Your order. You can track it from your account. For any questions, you will find our contact details on the Contact page; all the terms are on the Shipping page.
Support before and after purchase
Support before and after purchase
For advice on choosing a product, a technical question or an order already placed, the Buytutto customer service team is available Monday to Friday, 9:00 am to 1:00 pm and 2:00 pm to 6:00 pm.
You can message us on WhatsApp using the button on this page, or use the contact details on the Contact page. For a product you have already received, open a request from the Support page.
Description
The Fantini Cosmi UVR 700 MF HE heat recovery unit is a dual-flow ventilation unit for installation in a false ceiling and/or on the floor, with airflow from 650 to 1600 m³/h, M6 and F7 filters and an included control unit. It provides ventilation for small and medium-sized bars, restaurants, offices, meeting rooms, shops, gyms, dance halls and canteens.

High-efficiency single-phase EC fans
The unit uses high-efficiency single-phase EC fans, with speed adjustable progressively and independently for each fan. The forward-curved fans installed in the size 1600 and larger models already meet IE5 and ERP2020 efficiency requirements. The UVR-HE 500, UVR-HE 700 and UVR-HE 1200 models have backward-curved centrifugal fans.
Cross-flow recovery in 23 mm insulated casing
The high-efficiency cross-flow recovery unit works inside an external structure in galvanised sheet steel, with a thermo-acoustic panel in 23 mm expanded polyurethane at 40 kg/m³ density. A fire-retardant sound-absorbing mat is placed on the lower and upper panels.
M6 and F7 filters, clogging alert
The M6 filter is on the outdoor air intake and the F7 filter on the fresh air supply. Both are inspectable and replaceable through the access panels in the cover. A pressure switch on the supply filters and an LED light on the control unit signal clogging.
Motorised bypass and temperature probes
The motorised bypass damper can be controlled both manually and automatically. Two temperature probes measure the supply air and the return air. The control board is prepared for a CO2 or humidity sensor, both optional.
Control unit and RS485 port
The control unit is included, has an LCD display and is flush-mounted in a 3-module type 503 box. It manages the two fans in coupled or separate mode, monitors outdoor and indoor temperature and, with a CO2 sensor installed, adjusts ventilation according to air quality. The RS485 port allows connection of a DeG remote control, is compatible with the MODBUS interface and allows series connection with other DeG base boards.
IP55 panel and on-site installation
The electrical control panel is installed on board with IP55 protection. The airflow configuration can also be defined on site, and the mounting brackets are included in the structure. The condensate collection tray has a drain tube in transparent plastic.

Frequently asked questions
Where is the Fantini Cosmi UVR 700 MF HE installed?
Which filters does the Fantini Cosmi UVR 700 MF HE have?
Can the Fantini Cosmi UVR 700 MF HE be connected to an external control system?
Is a CO2 sensor needed to control ventilation on the Fantini Cosmi UVR 700 MF HE?
In which premises is the Fantini Cosmi UVR 700 MF HE used?
What does the Fantini Cosmi UVR 700 MF HE control unit include?
Technical specifications
| Model and codes | |
| Model | UVR 700 MF HE |
| Series | UVR-HE 750 |
| Configuration | horizontal/vertical |
| Installation | in a false ceiling and/or on the floor |
| Performance | |
| Airflow | from 650 to 1600 m³/h |
| Recovery | high-efficiency cross-flow |
| Fans | high-efficiency single-phase EC |
| Forward-curved fans (size 1600 and larger) | IE5 and ERP2020 |
| Backward-curved centrifugal fans | UVR-HE 500, UVR-HE 700, UVR-HE 1200 |
| Structure and insulation | |
| External structure | galvanised sheet steel |
| Insulation | expanded polyurethane, 23 mm thickness, 40 kg/m³ density |
| Mat | fire-retardant sound-absorbing, on the lower and upper panels |
| Filters | |
| Outdoor air intake filter | M6 |
| Fresh air supply filter | F7 |
| Control and panel | |
| Control unit | included, with LCD display |
| Control unit mounting | flush-mounted, 3-module type 503 box |
| Control panel | IP55, on board |
| Port | RS485 (DeG remote control, MODBUS) |
| Functions | motorised bypass damper, supply filter pressure switch, two temperature probes, mounting brackets included, condensate tray with drain tube |
| Accessories | |
| Available accessories | hydronic post-heating coils, hydronic post-cooling coils, electric pre- and post-heating coils |