Skip to content

Description

Fantini Cosmi UVR 1600 MF HE is a dual-flow heat recovery unit for installation in a false ceiling and/or on the floor, with airflow from 650 to 1600 m³/h. It ventilates small and medium-sized bars, restaurants, offices, meeting rooms, shops, gyms, dance halls and canteens, with a high-efficiency cross-flow heat exchanger and a 23 mm insulating panel.

Grey sheet-metal heat recovery unit with two round vents on the front and an electrical panel with a red switch

High-efficiency single-phase EC fans

The Fantini Cosmi UVR 1600 MF HE is equipped with high-efficiency single-phase EC fans. The forward-curved fans installed in the size 1600 and larger models already meet IE5 and ERP2020 efficiency requirements. The speed of each fan is adjustable progressively and independently of the other.

Structure with 23 mm polyurethane insulation

The external structure is made of galvanised sheet steel, with a thermo-acoustic panel in 23 mm expanded polyurethane with a density of 40 kg/m³. A fire-retardant sound-absorbing mat is placed on the lower and upper panels.

Two temperature probes and motorised bypass

Two temperature probes measure the supply air and the return air. The motorised bypass damper can be controlled either manually or automatically. A pressure switch signals clogging of the supply filters, also indicated by an LED light.

LCD control unit included

In the Fantini Cosmi UVR 1600 MF HE the LCD control unit is included and allows remote control with manual and automatic operation. It manages the bypass and controls the two fans in coupled or separate mode. It is flush-mounted in a 3-module type 503 box.

RS485 port for remote control and MODBUS

The RS485 port of the Fantini Cosmi UVR 1600 MF HE can connect a single DeG remote control, be compatible with the MODBUS interface, or be wired in series with other DeG base boards, managing multiple units with a single remote control. The board is prepared for a CO2 or humidity sensor, both optional.

M6 and F7 filters inspectable from the cover

The M6 filter is located on the outdoor air intake and the F7 filter on the fresh air supply. Both are inspectable and replaceable through the access panels made in the cover of the units. The airflow configuration can also be defined on site.

Accessory air treatment coils

The following accessory coils are available: hydronic post-heating coils, hydronic post-cooling coils, and electric pre- and post-heating coils.

Technical table of UVR recovery units with codes, airflows, power, absorption, class and noise levels for the four models

Frequently asked questions

What environments is the Fantini Cosmi UVR 1600 MF HE designed for?
It is designed for ventilating small and medium-sized commercial and service-sector spaces such as bars, restaurants, offices, meeting rooms, shops, gyms, dance halls and canteens.
Where is the UVR 1600 MF HE heat recovery unit installed?
The Fantini Cosmi UVR 1600 MF HE is installed in a false ceiling and/or on the floor, and its airflow configuration can also be defined on site.
Which filters does the Fantini Cosmi UVR 1600 MF HE have?
The Fantini Cosmi UVR 1600 MF HE has an M6 filter on the outdoor air intake and an F7 filter on the fresh air supply, both inspectable and replaceable through the access panels in the cover.
How can you tell when the filters of the Fantini Cosmi UVR 1600 MF HE are clogged?
The Fantini Cosmi UVR 1600 MF HE has a pressure switch that monitors clogging of the supply filters, with an LED light showing their status.
Can the fan speed of the UVR 1600 MF HE be adjusted?
Yes, in the Fantini Cosmi UVR 1600 MF HE the speed of each fan is adjustable progressively and independently, and the two fans can be controlled in coupled or separate mode.
Can a CO2 sensor be connected to the UVR 1600 MF HE heat recovery unit?
Yes, the control board of the Fantini Cosmi UVR 1600 MF HE is prepared for a CO2 or humidity sensor, both optional, and allows ventilation to be adapted to air quality.

Technical specifications

Model and codes
ModelUVR 1600 MF HE
Configurationhorizontal/vertical
Airflow and installation
Airflowfrom 650 to 1600 m³/h
Installationin a false ceiling and/or on the floor
Airflow configurationcan also be defined on site
Fans and efficiency
Fanshigh-efficiency single-phase EC
Forward-curved fans, size 1600 and largerIE5 and ERP2020 requirements met
Backward-curved centrifugal fansUVR-HE 500, 700, 1200 models
Structure and insulation
External structuregalvanised sheet steel
Insulation23 mm expanded polyurethane panel
Insulation density40 kg/m³
Sound-absorbing matfire-retardant, on the lower and upper panels
Filters and sensors
Outdoor air intake filterM6
Fresh air supply filterF7
Temperature probes2 (supply and extract)
Pressure switchclogging of supply filters
Panel, control and connections
Electrical control panelon-board, IP55
PortRS485 (DeG remote control, MODBUS)
Control unitincluded, with LCD display
Control unit mountingflush-mounted in a 3-module type 503 box
Bypassmotorised damper, manual or automatic
Supply
Mounting bracketsincluded in the structure
Condensate draincollection tray and transparent plastic tube
Available accessorieshydronic post-heating and post-cooling coils, electric pre- and post-heating coils