Skip to content

Description

Ferroli Omnia ST 3.2 16 (code 0XHTGSWA) is a single-phase reversible air-to-water heat pump with R32 gas, from the Ferroli split Full Inverter range. It heats and cools the system water and produces domestic hot water (DHW) with a 240 L storage tank built into the indoor unit. Useful output of 15.9 kW in heating with water at 35 °C and 14.0 kW in cooling with water at 7 °C.

Air-to-water heat pump with a white column indoor unit and an outdoor unit with a grille fan

Full Inverter: compressor, fan and pump with DC modulation

Ferroli's Full Inverter design uses DC inverter modulation on the three components that consume the most energy: compressor, fan and pump. The output follows the heat load, with high efficiency and energy savings. The concept also reduces inrush currents, avoiding grid surges and ensuring a longer useful life for the components.

The Ferroli Omnia ST 3.2 16 operates down to -25 °C outdoor temperature and produces hot water up to 65 °C under nominal conditions. Its operating range is among the widest on the market, and its noise levels are among the lowest.

Bright bathroom with a white floor-standing unit beside the washing machine and a potted plant

Built-in 240 L DHW storage

Compared with the OMNIA S 3.2, the OMNIA ST 3.2 has the domestic hot water storage built directly into the indoor unit. For sizes 4 to 10 the storage is 190 L; for sizes 12 to 16T it is 240 L.

The 3-way diverter valve is supplied as standard: when the DHW sensor calls, the unit diverts to the cylinder with a dedicated DHW setpoint. The Fast DHW function gives priority to DHW production to bring the cylinder up to setpoint in the shortest possible time. The cylinder's electric heater serves as a booster, for anti-legionella, or as a backup source in case of a fault, and the anti-legionella function sets weekly cycles.

Indoor unit with complete hydronic module

The indoor unit houses the hydraulic circuit with the main components pre-installed: stainless steel plate heat exchanger, pressure gauge and pressure sensors, expansion vessel, safety valve, automatic air vent and DC brushless circulator.

Diagram of a heat pump with domestic hot water cylinder, showing the accessory kits and the numbered component legend

The module can be customised with an 18 L buffer kit, a solar integration kit for the storage, or a kit for managing two zones, direct and mixed, to provide two different temperatures at the emitters.

Onboard controls and management with Connect CRP

The controls are included and located on the unit: the user interface has a 2.8-inch graphic display with Capsense technology. The controls are used to set heating and cooling weather curves.

Black and white touch control panel with digital display, plus and minus keys and power button

The interface communicates with the Connect CRP and Connect CRP Zone systems, which manage up to 8 thermostats split across 2 zones, one direct and one mixed. The unit can be interfaced with BMS/BACS systems via the Modbus protocol.

Control functions: Silent, ECO, Smart Grid and external contacts

Silent mode reduces compressor frequency and fan speed to lower noise, programmable by time bands. The ECO function uses a dedicated setpoint, settable with a daily time band.

The digital Smart Grid inputs receive a signal from the photovoltaic system and from the electricity grid, to optimise consumption and energy bills. On and off are managed by an external contact, for example from the zone thermostat, and the heating/cooling signal comes from outside. Frost protection runs the heat pump in heating with the circulator ON and any electric booster.

Modern kitchen with white and brown cabinets

Frequently asked questions

What is the Ferroli Omnia ST 3.2 16 used for?
The Ferroli Omnia ST 3.2 16 is a reversible air-to-water heat pump: it heats and cools the system water and produces domestic hot water with the 240 L storage built into the indoor unit. It can be integrated with a Ferroli boiler.
Down to what outdoor temperature does the Ferroli Omnia ST 3.2 16 operate?
The Ferroli Omnia ST 3.2 16 operates down to -25 °C outdoor temperature and produces hot water up to 65 °C under nominal conditions.
What does Full Inverter mean on the Ferroli Omnia ST 3.2 16?
It means the compressor, fan and pump of the Ferroli Omnia ST 3.2 16 are modulated by DC inverter, so the output follows the heat load and inrush currents are reduced, avoiding grid surges.
Can the Ferroli Omnia ST 3.2 16 be connected to photovoltaics or a zone thermostat?
Yes: the Ferroli Omnia ST 3.2 16 has digital Smart Grid inputs for a signal from a photovoltaic system and from the electricity grid. On/off and heating/cooling can also be managed via external contacts, for example from the zone thermostat.
How is the Ferroli Omnia ST 3.2 16 controlled?
The Ferroli Omnia ST 3.2 16 has the controls included on the unit, with a 2.8-inch graphic display and Capsense technology. It can be interfaced with BMS/BACS systems via the Modbus protocol and manage up to 8 thermostats in 2 zones with Connect CRP systems.
What is the difference between the Ferroli Omnia ST 3.2 and the OMNIA S 3.2?
The Ferroli Omnia ST 3.2 has the domestic hot water storage built into the indoor unit, while the OMNIA S 3.2 does not. For size 16 the built-in storage is 240 L.

Technical specifications

Model and codes
ModelOmnia ST 3.2 16
Product code0XHTGSWA
Typereversible air-to-water heat pump, single-phase
Refrigerant gasR32
Power and performance
Useful heating output with water at 35 °C15.9 kW
Useful heating output with water at 45 °C16.0 kW
Useful heating output with water at 55 °C16.0 kW
Power input in heating with water at 35 °C3.53 kW
Power input in heating with water at 45 °C4.57 kW
Power input in heating with water at 55 °C5.61 kW
Water flow rate in heating with water at 35 °C2735 l/h
Water flow rate in heating with water at 45 °C2752 l/h
Water flow rate in heating with water at 55 °C1720 l/h
Useful cooling output with water at 7 °C14.0 kW
Useful cooling output with water at 18 °C13.6 kW
Power input in cooling with water at 7 °C5.60 kW
Power input in cooling with water at 18 °C3.77 kW
Water flow rate in cooling with water at 7 °C2408 l/h
Water flow rate in cooling with water at 18 °C2563 l/h
Hot water and storage
Integrated DHW storage240 L
Maximum hot water temperature under nominal conditions65 °C
Outdoor air operating limit-25 °C
Dimensions and weight
Outdoor unit (W x H x D)1118 x 865 x 523 mm
Outdoor unit weight96.0 kg
Indoor unit (W x H x D)595 x 1860 x 700 mm
Functions and equipment
Controlson the unit, included, 2.8-inch graphic display
FunctionsSilent mode, ECO, ON/OFF from external contact, heating/cooling from external contacts, frost protection, anti-legionella, Fast DHW
ConnectivityModbus protocol for BMS/BACS; Smart Grid inputs from photovoltaics and grid
Available kits18 L buffer kit, solar integration kit, 2-zone kit; Connect CRP (up to 8 thermostats, 2 zones)
Standard equipment3-way diverter valve, DHW cylinder electric heater