Ferroli
Heat Pump Omnia ST 3.2 R32 Ferroli 16 Reversible Air-to-Water Single-Phase With Electrical Integration System
- 15,9 kW heating
- Class A

What size do I need?
For heat pumps and fan coils the right output is worked out by the installer on your home: heat loss, system, climate zone. Send us your measurements and we will reply with a quote.
Couldn't load pickup availability
Shipping and delivery
Shipping and delivery
Timing. With online payment, your order leaves with express courier and arrives within 1-2 working days. In remote areas and on islands, a few extra days may be needed: the estimated delivery date for your postcode is shown under “When it arrives”.
Costs. For orders under €80, shipping costs €8. Delivery to your floor is available for an additional charge.
Availability. Each product shows whether it is in stock, whether only a few units are left, or whether it is sold out; for sold-out products, you can leave your email and we will let you know as soon as they are back in stock.
Your order. You can track it from your account. For any questions, you will find our contact details on the Contact page; all the terms are on the Shipping page.
Support before and after purchase
Support before and after purchase
For advice on choosing a product, a technical question or an order already placed, the Buytutto customer service team is available Monday to Friday, 9:00 am to 1:00 pm and 2:00 pm to 6:00 pm.
You can message us on WhatsApp using the button on this page, or use the contact details on the Contact page. For a product you have already received, open a request from the Support page.
Description
Ferroli Omnia ST 3.2 16 (code 0XHTGSWA) is a single-phase reversible air-to-water heat pump with R32 gas, from the Ferroli split Full Inverter range. It heats and cools the system water and produces domestic hot water (DHW) with a 240 L storage tank built into the indoor unit. Useful output of 15.9 kW in heating with water at 35 °C and 14.0 kW in cooling with water at 7 °C.

Full Inverter: compressor, fan and pump with DC modulation
Ferroli's Full Inverter design uses DC inverter modulation on the three components that consume the most energy: compressor, fan and pump. The output follows the heat load, with high efficiency and energy savings. The concept also reduces inrush currents, avoiding grid surges and ensuring a longer useful life for the components.
The Ferroli Omnia ST 3.2 16 operates down to -25 °C outdoor temperature and produces hot water up to 65 °C under nominal conditions. Its operating range is among the widest on the market, and its noise levels are among the lowest.

Built-in 240 L DHW storage
Compared with the OMNIA S 3.2, the OMNIA ST 3.2 has the domestic hot water storage built directly into the indoor unit. For sizes 4 to 10 the storage is 190 L; for sizes 12 to 16T it is 240 L.
The 3-way diverter valve is supplied as standard: when the DHW sensor calls, the unit diverts to the cylinder with a dedicated DHW setpoint. The Fast DHW function gives priority to DHW production to bring the cylinder up to setpoint in the shortest possible time. The cylinder's electric heater serves as a booster, for anti-legionella, or as a backup source in case of a fault, and the anti-legionella function sets weekly cycles.
Indoor unit with complete hydronic module
The indoor unit houses the hydraulic circuit with the main components pre-installed: stainless steel plate heat exchanger, pressure gauge and pressure sensors, expansion vessel, safety valve, automatic air vent and DC brushless circulator.

The module can be customised with an 18 L buffer kit, a solar integration kit for the storage, or a kit for managing two zones, direct and mixed, to provide two different temperatures at the emitters.
Onboard controls and management with Connect CRP
The controls are included and located on the unit: the user interface has a 2.8-inch graphic display with Capsense technology. The controls are used to set heating and cooling weather curves.

The interface communicates with the Connect CRP and Connect CRP Zone systems, which manage up to 8 thermostats split across 2 zones, one direct and one mixed. The unit can be interfaced with BMS/BACS systems via the Modbus protocol.
Control functions: Silent, ECO, Smart Grid and external contacts
Silent mode reduces compressor frequency and fan speed to lower noise, programmable by time bands. The ECO function uses a dedicated setpoint, settable with a daily time band.
The digital Smart Grid inputs receive a signal from the photovoltaic system and from the electricity grid, to optimise consumption and energy bills. On and off are managed by an external contact, for example from the zone thermostat, and the heating/cooling signal comes from outside. Frost protection runs the heat pump in heating with the circulator ON and any electric booster.

Frequently asked questions
What is the Ferroli Omnia ST 3.2 16 used for?
Down to what outdoor temperature does the Ferroli Omnia ST 3.2 16 operate?
What does Full Inverter mean on the Ferroli Omnia ST 3.2 16?
Can the Ferroli Omnia ST 3.2 16 be connected to photovoltaics or a zone thermostat?
How is the Ferroli Omnia ST 3.2 16 controlled?
What is the difference between the Ferroli Omnia ST 3.2 and the OMNIA S 3.2?
Technical specifications
| Model and codes | |
| Model | Omnia ST 3.2 16 |
| Product code | 0XHTGSWA |
| Type | reversible air-to-water heat pump, single-phase |
| Refrigerant gas | R32 |
| Power and performance | |
| Useful heating output with water at 35 °C | 15.9 kW |
| Useful heating output with water at 45 °C | 16.0 kW |
| Useful heating output with water at 55 °C | 16.0 kW |
| Power input in heating with water at 35 °C | 3.53 kW |
| Power input in heating with water at 45 °C | 4.57 kW |
| Power input in heating with water at 55 °C | 5.61 kW |
| Water flow rate in heating with water at 35 °C | 2735 l/h |
| Water flow rate in heating with water at 45 °C | 2752 l/h |
| Water flow rate in heating with water at 55 °C | 1720 l/h |
| Useful cooling output with water at 7 °C | 14.0 kW |
| Useful cooling output with water at 18 °C | 13.6 kW |
| Power input in cooling with water at 7 °C | 5.60 kW |
| Power input in cooling with water at 18 °C | 3.77 kW |
| Water flow rate in cooling with water at 7 °C | 2408 l/h |
| Water flow rate in cooling with water at 18 °C | 2563 l/h |
| Hot water and storage | |
| Integrated DHW storage | 240 L |
| Maximum hot water temperature under nominal conditions | 65 °C |
| Outdoor air operating limit | -25 °C |
| Dimensions and weight | |
| Outdoor unit (W x H x D) | 1118 x 865 x 523 mm |
| Outdoor unit weight | 96.0 kg |
| Indoor unit (W x H x D) | 595 x 1860 x 700 mm |
| Functions and equipment | |
| Controls | on the unit, included, 2.8-inch graphic display |
| Functions | Silent mode, ECO, ON/OFF from external contact, heating/cooling from external contacts, frost protection, anti-legionella, Fast DHW |
| Connectivity | Modbus protocol for BMS/BACS; Smart Grid inputs from photovoltaics and grid |
| Available kits | 18 L buffer kit, solar integration kit, 2-zone kit; Connect CRP (up to 8 thermostats, 2 zones) |
| Standard equipment | 3-way diverter valve, DHW cylinder electric heater |