Rhoss
Split Air/Water Inverter Heat Pump Rhoss Electa-Ecos.2-B 14 kW MHAITI 114M + IUB 16M R-32 A+++
- 14,5 kW heating
- Class A+++

What size do I need?
For heat pumps and fan coils the right output is worked out by the installer on your home: heat loss, system, climate zone. Send us your measurements and we will reply with a quote.
Couldn't load pickup availability
Shipping and delivery
Shipping and delivery
Timing. With online payment, your order leaves with express courier and arrives within 1-2 working days. In remote areas and on islands, a few extra days may be needed: the estimated delivery date for your postcode is shown under “When it arrives”.
Costs. For orders under €80, shipping costs €8. Delivery to your floor is available for an additional charge.
Availability. Each product shows whether it is in stock, whether only a few units are left, or whether it is sold out; for sold-out products, you can leave your email and we will let you know as soon as they are back in stock.
Your order. You can track it from your account. For any questions, you will find our contact details on the Contact page; all the terms are on the Shipping page.
Support before and after purchase
Support before and after purchase
For advice on choosing a product, a technical question or an order already placed, the Buytutto customer service team is available Monday to Friday, 9:00 am to 1:00 pm and 2:00 pm to 6:00 pm.
You can message us on WhatsApp using the button on this page, or use the contact details on the Contact page. For a product you have already received, open a request from the Support page.
Description
Rhoss Electa-Ecos.2-B is a reversible two-section air/water heat pump: the MHAITI 114M outdoor unit and the IUB 16M indoor unit (code EESB2IU16M). It serves low- and medium-temperature systems for heating, cooling and domestic hot water. The system has class A+++ for heating at 35 °C, SCOP 4.65 and water output up to 60 °C, with R-32 refrigerant gas.
IUB 16M indoor unit: pumping group, 3-way valve and touch-screen control
The IUB 16M indoor unit is made of galvanised and painted sheet steel. The pumping group includes an EC circulator, 3 bar safety valve, flow switch, 10 l expansion vessel, pressure gauge and water filter supplied as standard. The 3-way valve manages domestic hot water production, and the water-side plate heat exchanger in stainless steel comes with an anti-freeze heater.
MHAITI 114M outdoor unit: inverter compressor and DC fans
The compressor is a hermetic twin rotary DC Inverter with vapour injection, with a refrigerant circuit featuring an economiser and electronic expansion valve. The finned coil has Golden Fin anti-corrosion epoxy resin treatment. The fans with brushless DC motors continuously adjust rotation speed. The sound pressure is 47 dB(A) at 5 m in open field.

Seasonal efficiency: SCOP 4.65 at 35 °C and 3.50 at 55 °C
For the Rhoss Electa-Ecos.2-B, according to EN 14825, the low-temperature application (35 °C) has Pdesignh 12 kW, SCOP 4.65 and seasonal efficiency ηs 183 %, in class A+++. With medium temperature (55 °C) the value is Pdesignh 13 kW, SCOP 3.50 and ηs 137 %, in class A++. Data refer to “Average” climate conditions and to the classification of Regulations (EU) No 811/2013 and No 813/2013.
Heating and cooling performance according to EN 14511
In heating, with air at 7 °C DB - 6 °C WB and water at 40-45 °C, the heating capacity is 14.50 kW with COP 3.75. With water at 30-35 °C the heating capacity is 14.0 kW with COP 4.70. In cooling, with air at 35 °C DB and water at 12-7 °C, the cooling capacity is 11.3 kW with EER 2.80; with water at 23-18 °C it is 12.6 kW with EER 3.70.
Control from touch-screen, thermostat or smartphone
The touch-screen panel manages the 3-way valve, the rapid heating function for domestic hot water and the timed anti-legionella cycle. It allows weekly and daily time bands, holiday mode and anti-freeze function. Control can also be handed to a room thermostat, and the app for iOS and Android manages the unit from smartphone and tablet. The RS485 interface communicates using the Modbus RTU protocol.
Frequently asked questions
What refrigerant gas does the Rhoss Electa-Ecos.2-B heat pump use?
Which energy classes does the Rhoss Electa-Ecos.2-B have for heating?
Up to what water temperature can the Rhoss Electa-Ecos.2-B reach?
What does the IUB 16M indoor unit of the Rhoss Electa-Ecos.2-B include?
Can the Rhoss Electa-Ecos.2-B be controlled with a smartphone?
Is the first start-up of the Rhoss Electa-Ecos.2-B included?
Technical specifications
| Model and codes | |
| Outdoor unit | MHAITI 114M (EES02OU14M) |
| Indoor unit | IUB 16M (EESB2IU16M) |
| First start-up | optional, not included |
| Seasonal energy efficiency | |
| Low-temperature application (35 °C), Pdesignh (EN 14825) | 12 kW |
| Low-temperature application (35 °C), SCOP (EN 14825) | 4.65 |
| Low-temperature application (35 °C), seasonal efficiency ηs | 183 % |
| Low-temperature application (35 °C), energy class | A+++ |
| Medium-temperature application (55 °C), Pdesignh (EN 14825) | 13 kW |
| Medium-temperature application (55 °C), SCOP (EN 14825) | 3.50 |
| Medium-temperature application (55 °C), seasonal efficiency ηs | 137 % |
| Medium-temperature application (55 °C), energy class | A++ |
| Power and performance | |
| Heating (air 7 °C DB - 6 °C WB, water 40-45 °C), heating capacity | 14.50 kW |
| Heating (air 7 °C DB - 6 °C WB, water 40-45 °C), power input | 3.87 kW |
| Heating (air 7 °C DB - 6 °C WB, water 40-45 °C), COP | 3.75 |
| Heating (air 7 °C DB - 6 °C WB, water 30-35 °C), heating capacity | 14.0 kW |
| Heating (air 7 °C DB - 6 °C WB, water 30-35 °C), power input | 2.98 kW |
| Heating (air 7 °C DB - 6 °C WB, water 30-35 °C), COP | 4.70 |
| Cooling (air 35 °C DB, water 12-7 °C), cooling capacity | 11.3 kW |
| Cooling (air 35 °C DB, water 12-7 °C), power input | 4.04 kW |
| Cooling (air 35 °C DB, water 12-7 °C), EER | 2.80 |
| Cooling (air 35 °C DB, water 23-18 °C), cooling capacity | 12.6 kW |
| Cooling (air 35 °C DB, water 23-18 °C), power input | 3.41 kW |
| Cooling (air 35 °C DB, water 23-18 °C), EER | 3.70 |
| Useful circulator head | 54 kPa |
| Domestic hot water | production up to 60 °C; operation with outdoor air from -25 °C to +45 °C |
| Noise, power supply and connections | |
| Outdoor unit sound pressure | 47 dB(A) at 5 m in open field |
| Indoor unit electric heater | 2 x 3.0 n. x kW |
| Power supply | 230-1-50 V-ph-Hz |
| Max length / height difference of refrigerant lines | 15 / 15 m |
| Dimensions and weight | |
| MHAITI outdoor unit, width | 940 mm |
| MHAITI outdoor unit, height | 840 mm |
| MHAITI outdoor unit, depth | 460 mm |
| MHAITI outdoor unit, weight | 104 kg |
| IUB indoor unit, width | 460 mm |
| IUB indoor unit, height | 860 mm |
| IUB indoor unit, depth | 315 mm |
| IUB indoor unit, empty weight | 58 kg |
| Functions and equipment | |
| Functions | indoor unit with EC circulator, 10 l expansion vessel, 3-way valve for DHW, auxiliary electric heater, touch-screen panel, iOS and Android app, RS485 interface, digital outputs for pump contact and valve status |
| Accessories supplied separately | KSA rubber anti-vibration mounts; KPRE cabling for RS485 serial connection to the touch-screen panel |
| Refrigerant gas | R-32 |