Fondital
Gas Convector Heater Fondital Gazelle Evo 7000 Natural Gas 5.88 KW - Code GEIT701PR2
- 5,88 kW heating
- Natural gas

Couldn't load pickup availability
Shipping and delivery
Shipping and delivery
Timing. With online payment, your order leaves with express courier and arrives within 1-2 working days. In remote areas and on islands, a few extra days may be needed: the estimated delivery date for your postcode is shown under “When it arrives”.
Costs. For orders under €80, shipping costs €8. Delivery to your floor is available for an additional charge.
Availability. Each product shows whether it is in stock, whether only a few units are left, or whether it is sold out; for sold-out products, you can leave your email and we will let you know as soon as they are back in stock.
Your order. You can track it from your account. For any questions, you will find our contact details on the Contact page; all the terms are on the Shipping page.
Support before and after purchase
Support before and after purchase
For advice on choosing a product, a technical question or an order already placed, the Buytutto customer service team is available Monday to Friday, 9:00 am to 1:00 pm and 2:00 pm to 6:00 pm.
You can message us on WhatsApp using the button on this page, or use the contact details on the Contact page. For a product you have already received, open a request from the Support page.
Description
The Fondital Gazelle Evo 7000 natural gas heater (code GEIT701PR2) is a sealed-chamber gas convection heater with forced draught and full premixing, for heating domestic and industrial spaces. The nominal heat output is 5880 W (5.88 kW), the seasonal energy class for room heating is A and the seasonal efficiency (ηs) is 88%.
Sealed chamber and forced draught
The fully premixed burner has electronic ignition and ionisation flame control. The sealed chamber and forced draught are managed by a safety air pressure switch and a safety thermostat, doubled on the 5000 and 7000 models.
Brushless fans and aluminium heat exchanger
The combustion centrifugal fan and the convection tangential fan have high-efficiency brushless motors. The heat exchanger is made of die-cast aluminium with a heat recovery unit, and maximum electrical absorption is ≤ 30W.
Encoder control, LCD and weekly programming
The user interface has an encoder, four buttons and a large backlit LCD. Operation can be programmed on a weekly basis, and the room temperature selector includes a frost protection function. The remote control connects as an optional accessory.
Separate and extendable pipes
The intake and exhaust pipes are separate and extendable. The Gazelle Evo 7000 includes a built-in humidifier.
Installation and maintenance
The appliance must be installed on walls directly facing the outside, in compliance with current regulations. The minimum distances of the flue terminal from windows, openings, gutters, balconies, corners, ground and other terminals are shown in the following table.

Under D.M. No. 37 of 22 January 2008, installation and maintenance must be carried out by expert professionals who issue the declaration of conformity. The supplier's booklet requires annual maintenance by qualified personnel, and for the inspection certificate an authorised Technical Assistance Centre (CAT) is recommended.
Frequently asked questions
Which code should I choose for LPG?
How efficient is the Fondital Gazelle Evo 7000?
Can a remote control be connected to the Gazelle Evo 7000?
Does the Gazelle Evo 7000 need periodic maintenance?
Where can the Fondital Gazelle Evo 7000 be installed?
Does the Gazelle Evo 7000 have programming and a humidifier?
Technical specifications
| Colour | White |
| Natural gas code | GEIT701PR2 |
| LPG code | GEIT761PR2 |
| Series models | 3000 - 5000 - 7000 |
| LxHxD | 772x550x195 mm |
| Gross weight | 28 kg |
| Seasonal energy efficiency class for room heating | A |
| Seasonal energy efficiency for room heating (ηs) | 88% |
| Nominal heat input (Pnom) | 5.9 kW |
| Minimum heat input (Pmin) | 4.2 kW |
| Useful efficiency at nominal heat output (ηth,nom) | 91.8 % |
| Useful efficiency at minimum heat output (ηth,min) | 94.0 % |
| Nominal heat output | 6400 W |
| Reduced heat input | 4500 W |
| Nominal heat output | 5880 W |
| Reduced heat output | 4230 W |
| Efficiency at nominal heat input (natural gas) | 91.8 |
| Efficiency at nominal heat input (propane) | 91.7 |
| Efficiency at reduced heat input (natural gas) | 94.0 |
| Efficiency at reduced heat input (propane) | 93.8 |
| NOx emission class | 5 |
| Combustion chamber | Forced draught |
| Power supply voltage/frequency | 230 – 50 V/Hz |
| Electrical protection rating | 20 IP |
| Maximum electrical absorption | ≤ 30W |
| Gas connection diameter | G 1/2 M inches |
| External diameter of straight exhaust pipes (C13) | 2 x 55/2* mm |
| Note on C13 diameter | 2 x 55/2 refers to two pipes (one for air intake and one for flue gas exhaust), each shaped like a semicircle with a diameter of 55 mm |
| External diameter of split pipes (C53) | 35 or 60 mm |
| Functions | built-in humidifier; weekly operation programming; room temperature selector with frost protection function; gas valve with constant air-gas ratio; optional additional room sensor; optional remote control |

