Skip to content

Description

The Fondital Gazelle Evo 5000 is a natural gas convection heater, room-sealed with forced draught and premix combustion, for heating domestic and industrial spaces. It has a nominal heat output of 4520 W, class A seasonal energy efficiency and a seasonal efficiency of 88%.

Class A energy efficiency

The Fondital Gazelle Evo 5000 has class A seasonal energy efficiency for space heating, with seasonal efficiency (ηs) of 88%. Useful efficiency is 92.2 % at nominal heat input and 94.9 % at minimum heat input.

Room-sealed with forced draught

The Fondital Gazelle Evo 5000 is room-sealed with forced draught. The fully premixed burner has electronic ignition and ionisation flame control, while the gas valve maintains a constant air-gas ratio. The air safety pressure switch and safety thermostat complete the protections; there are 2 safety thermostats on the 5000 and 7000 models.

Brushless fans and aluminium heat exchanger

The Fondital Gazelle Evo 5000 has two fans with high-efficiency brushless motors: a centrifugal one for combustion and a tangential one for convection. The heat exchanger is made of die-cast aluminium with a high-efficiency heat recuperator.

Control with encoder, four buttons and backlit LCD

The user interface of the Fondital Gazelle Evo 5000 has an encoder, four buttons and a large backlit LCD. The room temperature selector has the frost protection function, and operation is programmed on a weekly basis. The remote control connects as an option, and the room sensor is an optional additional accessory.

Separate intake and exhaust pipes

The Fondital Gazelle Evo 5000 has separate, extendable intake and exhaust pipes, with a straight C13 exhaust and a split C53 exhaust.

Installation and safety distances

The Fondital Gazelle Evo 5000 must be installed on walls directly open to the outside; alternatively, other installations are arranged in compliance with current regulations. The distance from surrounding elements must respect the minimum distances shown in the table below.

Table of minimum positioning distances for the flue exhaust terminal, with reference letters A to P

Annual servicing and qualified personnel

Below 5 kW the heater is not considered a heating system and the energy efficiency check obligation falls away, but the requirements of the supplier's manual remain valid, which calls for annual servicing by qualified personnel. Servicing keeps the appliance in efficient and safe condition and extends its life; in case of breakdown or wear, extraordinary servicing is also required.

Under Ministerial Decree No. 37 of 22 January 2008, installation and servicing must be carried out by professionals who issue a declaration of conformity. For the check certificate, an authorised Technical Service Centre (CAT) is recommended.

Frequently asked questions

Is there a Fondital Gazelle Evo 5000 for LPG?
Yes, the Fondital Gazelle Evo 5000 also comes in an LPG version, with code GEIT561PR2. The version described on this page is the natural gas one, with code GEIT501PR2.
Which exhaust pipes are needed for the Fondital Gazelle Evo 5000?
The Fondital Gazelle Evo 5000 has separate intake and exhaust pipes: the straight C13 exhaust has an outer diameter of 2 x 55/2 mm, and the split C53 exhaust has an outer diameter of 35 or 60 mm.
Does the Fondital Gazelle Evo 5000 need annual servicing?
Yes. Although below 5 kW the heater is not considered a heating system, the supplier's manual requires annual servicing by qualified personnel.
Does the Fondital Gazelle Evo 5000 have a humidifier?
Yes, the Fondital Gazelle Evo 5000 has a built-in humidifier, along with the room temperature selector with frost protection and weekly operating programming.
Can the Fondital Gazelle Evo 5000 be controlled remotely?
Yes, the Fondital Gazelle Evo 5000 can be connected to an optional remote control. An additional room sensor is available as an optional accessory.
Who can install the Fondital Gazelle Evo 5000?
Under Ministerial Decree No. 37 of 22 January 2008, installation of the Fondital Gazelle Evo 5000 must be carried out by professionals who issue a declaration of conformity.

Technical specifications

Model and codes
ColourWhite
Natural gas codeGEIT501PR2
LPG codeGEIT561PR2
Energy efficiency
Seasonal space heating energy efficiency classA
Seasonal space heating energy efficiency (ηs)88%
Power and performance
Nominal heat input (Pnom)4.5 kW
Minimum heat input (Pmin)2.8 kW
Useful efficiency at nominal heat input (ηth,nom)92.2 %
Useful efficiency at minimum heat input (ηth,min)94.9 %
Nominal heat output4900 W
Reduced heat input3000 W
Nominal heat output4520 W
Reduced heat output2850 W
Efficiency at nominal heat input (natural gas)92.2
Efficiency at nominal heat input (propane)92.3
Efficiency at reduced heat input (natural gas)94.9
Efficiency at reduced heat input (propane)95.1
NOx emission class5
Combustion chamberForced draught
Electrical data
Supply voltage/frequency230 – 50 V/Hz
Electrical protection rating20 IP
Maximum power consumption≤ 30W
Connections
Gas connection diameterG 1/2 M inch
Outer diameter of straight exhaust pipes (C13)2 x 55/2 mm
Note on C13 diameter2 x 55/2 means two pipes, one for air intake and one for flue exhaust, each shaped like a semicircle with a diameter of 55 mm
Outer diameter of split pipes (C53)35 or 60 mm
Dimensions and weight
WxHxD667x550x195 mm
Gross weight24 kg
Features and supply
Functionsbuilt-in humidifier, weekly operating programming, room temperature selector with frost protection, air safety pressure switch, gas valve with constant air-gas ratio, optional additional room sensor, optional remote control
Model range3000 - 5000 - 7000