Skip to content

Description

The Fondital Gazelle Evo 3000 GPL gas radiator (code GEIT361PR2) is a sealed-chamber, forced-draught, fully premixed gas convector heater, in white, for heating domestic and industrial spaces. It has energy class A seasonal energy efficiency, with ηs 89%, and a nominal heat output of 2.7 kW, with a minimum output of 1.9 kW.

Die-cast aluminium heat exchanger with heat recovery

The heat exchanger is made of die-cast aluminium, with a high-efficiency heat recovery unit. The declared useful efficiencies are 93.7% at nominal heat output and 94.5% at minimum heat output.

Brushless fans for combustion and convection

The centrifugal combustion fan and the tangential convection fan have high-efficiency brushless motors. The maximum electrical absorption is 30 W.

Fully premixed burner with electronic ignition

The fully premixed burner has electronic ignition and ionisation flame control. The gas valve maintains a constant air-gas ratio.

Encoder control, four buttons and backlit LCD

The user interface has an encoder, four buttons and a large backlit LCD. The room temperature selector has the frost protection function, and operation programming is weekly.

An optional remote control and an additional optional room sensor can be connected.

Safety: air pressure switch, thermostat and microprocessor

The Gazelle Evo 3000 has an air pressure safety switch and a safety thermostat (two on the 5000 and 7000 models). The electronic control and management unit is fitted with a microprocessor.

Separate, extendable intake and exhaust pipes

Air intake and flue gas exhaust use separate, extendable pipes. The straight C13 flue has an external diameter of 2 x 55/2 mm, while the split C53 flue has a diameter of 35 or 60 mm.

Annual servicing and extraordinary maintenance

Below 5 kW the heater is not considered a heating system: only the energy efficiency check obligation falls away, but the requirements of the supplier's booklet still apply, which provide for annual servicing by qualified personnel.

Periodic servicing keeps the appliance in the best condition for efficiency and safety, with fuel savings, better comfort and a longer service life. In addition to periodic servicing, extraordinary maintenance should be planned in case of breakdown or wear.

To ensure efficiency and safety, we recommend having the service certificate completed by an authorised Technical Assistance Centre (CAT).

External wall installation and minimum clearances

The appliance must be installed on walls directly open to the outside; alternatively, alternative installations are arranged in compliance with current regulations. According to Ministerial Decree No. 37 of 22 January 2008, installation and servicing must be entrusted to experienced professionals who issue a declaration of conformity. Qualified personnel means those with specific technical competence in components of civil heating systems, or those qualified under current legislation.

Observe the minimum distance from surrounding elements, as shown in the flue terminal clearance table:

Table of minimum positioning distances for the flue exhaust terminal, with reference letters from A to P

Frequently asked questions

What type of heater is the Fondital Gazelle Evo 3000 GPL?
The Fondital Gazelle Evo 3000 GPL is a sealed-chamber, forced-draught, fully premixed gas convector heater. The LPG version has code GEIT361PR2.
How efficient is the Fondital Gazelle Evo 3000 GPL?
The Gazelle Evo 3000 has energy class A for seasonal room heating energy efficiency, with ηs 89%, and a useful efficiency of 93.7% at nominal heat output and 94.5% at minimum.
Does it still need annual servicing below 5 kW?
Yes. Below 5 kW the Gazelle Evo 3000 is not considered a heating system, and only the energy efficiency check obligation falls away, but the supplier's booklet still requires annual servicing by qualified personnel.
Who can install the Gazelle Evo 3000 heater?
Installation and servicing of the Gazelle Evo 3000 must be entrusted to experienced professionals who issue a declaration of conformity, as required by Ministerial Decree No. 37 of 22 January 2008.
Can a remote control be connected to the Gazelle Evo 3000?
Yes. An optional remote control and an additional optional room sensor can be connected to the Gazelle Evo 3000.
How are the flues of the Gazelle Evo 3000 connected?
The Gazelle Evo 3000 has separate, extendable intake and exhaust pipes. The straight C13 flue has an external diameter of 2 x 55/2 mm, and the split C53 flue has a diameter of 35 or 60 mm.

Technical specifications

Model and codes
ColourWhite
LPG codeGEIT361PR2
Natural gas codeGEIT301PR2
Models in the series3000 - 5000 - 7000
Energy efficiency
Seasonal room heating energy efficiency classA
Seasonal room heating energy efficiency (ηs)89%
Power and performance
Nominal heat input (Pnom)2.7 kW
Minimum heat input (Pmin)1.9 kW
Useful efficiency at nominal heat output (ηth,nom)93.7 %
Useful efficiency at minimum heat output (ηth,min)94.5 %
Nominal heat output2900 W
Reduced heat input2000 W
Nominal heat output2720 W
Reduced heat output1890 W
Efficiency at nominal heat input (natural gas)93.7
Efficiency at nominal heat input (propane)93.5
Efficiency at reduced heat input (natural gas)94.5
Efficiency at reduced heat input (propane)94.7
NOx emission class5
Combustion chamberForced draught
Electrical data
Power supply voltage/frequency230 – 50 V/Hz
Electrical protection rating20 IP
Maximum electrical absorption≤ 30 W
Connections and flue
Gas connection diameterG 1/2 M inches
External diameter of straight flue pipes (C13)2 x 55/2* mm
External diameter of split pipes (C53)35 or 60 mm
Note on 2 x 55/2two pipes, one for air intake and one for flue gas exhaust, each semicircular in shape with a diameter of 55 mm
Dimensions and weight
LxHxD547 x 550 x 195 mm
Gross weight20 kg
Functions and equipment
Functionsbuilt-in humidifier; weekly operation programming; room temperature selector with frost protection function; air pressure safety switch; gas valve with constant air-gas ratio; additional optional room sensor; optional remote control