Skip to content

Description

Riello Start 30 KIS GPL Low NOx is a combined wall-hung condensing boiler for small and medium-sized homes, providing space heating and domestic hot water. The key figures: seasonal space heating efficiency 93%, nominal output 19 kW for heating and 30 kW for domestic hot water, class A for heating and hot water. The package includes the flue kit, and the Hi-Comfort T100 chronothermostat (cod. 20193354) is included free of charge.

The Start range: 15, 25 and 30 kW sizes

The Start is Riello's new range of condensing boilers, updated in technology and functions. It comes in three sizes, 15, 25 and 30 kW, in the combined KIS versions and heating-only IS versions.

White wall-hung boiler with exposed flue outlet and, at bottom right

Touch panel with capacitive keys and buzzer

The control panel of the Riello Start 30 KIS is a touchscreen HMI with representative icons and capacitive keys with an audible "buzzer" tone. It is designed with ease of use in mind.

High-efficiency domestic hot water heat exchanger and hot water functions

The high-efficiency domestic hot water heat exchanger is developed by Riello. For hot water, the Riello Start 30 KIS has DHW delay, anti-cycling function and smart fan.

Built-in or outdoor installation, with IPX5D rating

The 25 KIS and 30 KIS models can be installed built-in. The boiler can also be installed outdoors in partially protected locations, with an electrical protection rating of IPX5D. The mounting bracket is already integrated in the boiler and the power cable is supplied.

Maintenance through front access to the heat exchanger

The heat exchanger is reached through front access, which makes maintenance and cleaning of the combustion chamber easier. The expansion vessel is side-mounted and holds 8 litres.

DIN-standard hydraulic group and low-consumption circulator

The hydraulic group has a DIN-standard sequence and the circulator is low-consumption. A high-head circulator with 7 m of head is available as an accessory.

Clean design and cover for connections

The design of the Riello Start 30 KIS is modern and streamlined. A cover for the lower connections under the boiler is available as an accessory for a seamless look.

Natural gas as standard, LPG conversion with accessories

The supplier's data sheet indicates natural gas operation as standard. The conversion to LPG (G31) and propane air is achieved with accessories, carried out by the installer or the authorised service technician. The model is named GPL, so it is worth checking the configuration before installation.

Frequently asked questions

What is the difference between the KIS and IS versions?
The Riello Start 30 KIS is the combined version, providing space heating and domestic hot water. The IS version is heating only, and the Start range comes in 15, 25 and 30 kW sizes.
What is the output for domestic hot water?
The Riello Start 30 KIS GPL Low NOx has a nominal DHW heat output of 30.00 kW and a reduced DHW heat input of 3.95 kW, with a high-efficiency domestic hot water heat exchanger developed by Riello.
Can it be installed built-in?
Yes, the 25 KIS and 30 KIS models of the Riello Start can be installed built-in.
Can it be installed outdoors?
The Riello Start 30 KIS GPL Low NOx has an electrical protection rating of IPX5D and can be installed outdoors in partially protected locations.
How is the Riello Start 30 KIS serviced?
The Riello Start 30 KIS GPL Low NOx has front access to the heat exchanger, which makes maintenance and cleaning of the combustion chamber easier.
What does the control panel of the Riello Start 30 KIS offer?
The panel of the Riello Start 30 KIS is a touchscreen HMI with representative icons, capacitive keys and an audible buzzer tone.

Technical specifications

Model and codes
ModelRiello Start 30 KIS GPL Low NOx
Code20187407
Free chronothermostatHi-Comfort T100, cod. 20193354
Flue kitcoaxial or twin-pipe
Energy efficiency
Seasonal space heating energy efficiency classA
Water heating energy efficiency classA
Nominal output P19 kW
Seasonal space heating energy efficiency93%
Output and performance
Heating, nominal heat input20.00 kW
Heating, nominal heat output (80÷60 °C)24.38 kW
Heating, nominal heat output (50÷30 °C)26.78 kW
Heating, reduced heat input3.95 kW
Heating, reduced heat output (80÷60 °C)3.79 kW
Heating, reduced heat output (50÷30 °C)4.09 kW
DHW, nominal heat input30.00 kW
DHW, nominal heat output30.00 kW
DHW, reduced heat input3.95 kW
DHW, reduced heat output (*)3.95 kW
Heating circuit
Maximum pressure3 bar
Minimum pressure for standard operation0.25 bar
Maximum temperature90 °C
Pump, maximum head available to the system408 mbar
Pump, flow rate at head1000 l/h
Diaphragm expansion vessel8 l
Expansion vessel pre-charge1 bar
Dimensions and weight
Dimensions (h x w x d)780 x 332 x 400 mm
Weight37 kg
Functions and equipment
Modulation ratio1:8
Electrical protection ratingIPX5D
Fuelnatural gas as standard, convertible to LPG (G31) and propane air with accessories
DHW functionsDHW delay, anti-cycling function, smart fan
Hydraulic groupDIN-standard sequence
Heating controlstandard, with outdoor sensor available as an accessory
Flue flangestandard, with dedicated flue fittings
Installationbuilt-in (25 KIS and 30 KIS) or outdoors in partially protected locations
Mounting bracketintegrated in the boiler
Power cablesupplied