Riello
Condensing Boiler Riello Start 25 Kis Code 20187404 Natural Gas 25 kW + Flue Kit + Hi-Comfort T100 Programmable Thermostat Code 20193354 Included Free **PROMO**
- 25 kW hot water
- Class A
- Natural gas

Couldn't load pickup availability
Shipping and delivery
Shipping and delivery
Timing. With online payment, your order leaves with express courier and arrives within 1-2 working days. In remote areas and on islands, a few extra days may be needed: the estimated delivery date for your postcode is shown under “When it arrives”.
Costs. For orders under €80, shipping costs €8. Delivery to your floor is available for an additional charge.
Availability. Each product shows whether it is in stock, whether only a few units are left, or whether it is sold out; for sold-out products, you can leave your email and we will let you know as soon as they are back in stock.
Your order. You can track it from your account. For any questions, you will find our contact details on the Contact page; all the terms are on the Shipping page.
Support before and after purchase
Support before and after purchase
For advice on choosing a product, a technical question or an order already placed, the Buytutto customer service team is available Monday to Friday, 9:00 am to 1:00 pm and 2:00 pm to 6:00 pm.
You can message us on WhatsApp using the button on this page, or use the contact details on the Contact page. For a product you have already received, open a request from the Support page.
Description
The Riello Start 25 KIS condensing boiler (Code 20187404) is a combined natural gas boiler for heating and domestic hot water, designed for small and medium-sized homes. It has a seasonal space heating efficiency of 93%, class A for both space heating and water heating, a domestic hot water output of 25 kW and a modulation ratio of 1:8.
93% seasonal efficiency in class A
The Riello Start 25 KIS is class A for space heating and class A for water heating. Its seasonal space heating energy efficiency is 93%. In heating mode the rated output P is 19 kW, with a nominal heat input of 20.00 kW.
1:8 modulation and reduced heat input from 3.10 kW
The modulation ratio of the Riello Start 25 KIS is 1:8. In heating mode the reduced heat input is 3.10 kW, with a reduced heat output of 2.94 kW at 80÷60 °C and 3.04 kW at 50÷30 °C.
High-efficiency Riello domestic hot water exchanger
Domestic hot water is produced by a high-efficiency exchanger developed by Riello, with a nominal domestic hot water heat output of 25.00 kW. The domestic hot water functions include domestic hot water delay, anti-cycling function and smart fan.
HMI touch panel with capacitive buttons and buzzer
The control panel of the Riello Start 25 KIS is an HMI touchscreen with representative icons and capacitive buttons with a buzzer sound. Heating control is supplied as standard in combination with an external sensor, available as an accessory.
Linear design, lower connection cover as an accessory
The design is modern and linear. The cover for the lower connections under the boiler is available as an accessory for a more integrated look. The 8-litre side expansion vessel is on board the boiler.

Recessed or external installation with IPX5D rating
The 25 KIS model can be installed recessed, or externally in partly protected locations with an IPX5D protection rating. The mounting rail is already integrated into the boiler and the power cable is supplied. The hydraulic group has a standard DIN sequence.
Front-access maintenance and flue kit with standard flange
The heat exchanger is accessible from the front for maintenance and cleaning of the combustion chamber. The flue flange is supplied as standard with dedicated flue fittings. The flue kit is available in coaxial or split versions.
Natural gas as standard, LPG with conversion kit
The Riello Start 25 KIS runs on natural gas as standard. Conversion to LPG (G31) and propane air is possible with accessories; the conversion must be carried out by the installer or the authorised service engineer.
Low-consumption circulator, high-head version as an accessory
The circulator is low consumption, IEE 0.20. A 7 m high-head circulator is available as an accessory.
Frequently asked questions
What type of boiler is the Riello Start 25 KIS?
Does the Riello Start 25 KIS run on natural gas or LPG?
Can the Riello Start 25 KIS be installed recessed?
Which flue kit is needed with the Riello Start 25 KIS?
What is included free with the Riello Start 25 KIS?
Technical specifications
| Model and codes | |
| Model | Riello Start 25 KIS |
| Code | 20187404 |
| Programmable thermostat included free | Hi-Comfort T100, Code 20193354 |
| Energy efficiency | |
| Seasonal space heating energy efficiency class | A |
| Water heating energy efficiency class | A |
| Rated output P | 19 kW |
| Seasonal space heating energy efficiency | 93% |
| Output and performance for heating | |
| Nominal heat input | 20.00 kW |
| Nominal heat output (80÷60 °C) | 19.38 kW |
| Nominal heat output (50÷30 °C) | 20.92 kW |
| Reduced heat input | 3.10 kW |
| Reduced heat output (80÷60 °C) | 2.94 kW |
| Reduced heat output (50÷30 °C) | 3.04 kW |
| Output and performance for domestic hot water | |
| Nominal heat input | 25.00 kW |
| Nominal heat output | 25.00 kW |
| Reduced heat input | 3.10 kW |
| Reduced heat output (*) | 3.10 kW |
| Heating operation | |
| Maximum pressure | 3 bar |
| Minimum pressure for standard operation | 0.25 bar |
| Maximum temperature | 90 °C |
| Pump, maximum head available to the system | 408 mbar |
| Pump, reference flow rate | 1000 l/h |
| Diaphragm expansion vessel | 8 l |
| Expansion vessel pre-charge | 1 bar |
| Dimensions and weight | |
| Dimensions (H x W x D) | 780 x 332 x 400 mm |
| Weight | 37 kg |
| Features and equipment | |
| Power supply | natural gas, convertible to LPG (G31) with accessories |
| Modulation ratio | 1:8 |
| Electrical protection rating | IPX5D |