Skip to content

Description

The Riello Start 25 KIS condensing boiler (Code 20187404) is a combined natural gas boiler for heating and domestic hot water, designed for small and medium-sized homes. It has a seasonal space heating efficiency of 93%, class A for both space heating and water heating, a domestic hot water output of 25 kW and a modulation ratio of 1:8.

93% seasonal efficiency in class A

The Riello Start 25 KIS is class A for space heating and class A for water heating. Its seasonal space heating energy efficiency is 93%. In heating mode the rated output P is 19 kW, with a nominal heat input of 20.00 kW.

1:8 modulation and reduced heat input from 3.10 kW

The modulation ratio of the Riello Start 25 KIS is 1:8. In heating mode the reduced heat input is 3.10 kW, with a reduced heat output of 2.94 kW at 80÷60 °C and 3.04 kW at 50÷30 °C.

High-efficiency Riello domestic hot water exchanger

Domestic hot water is produced by a high-efficiency exchanger developed by Riello, with a nominal domestic hot water heat output of 25.00 kW. The domestic hot water functions include domestic hot water delay, anti-cycling function and smart fan.

HMI touch panel with capacitive buttons and buzzer

The control panel of the Riello Start 25 KIS is an HMI touchscreen with representative icons and capacitive buttons with a buzzer sound. Heating control is supplied as standard in combination with an external sensor, available as an accessory.

Linear design, lower connection cover as an accessory

The design is modern and linear. The cover for the lower connections under the boiler is available as an accessory for a more integrated look. The 8-litre side expansion vessel is on board the boiler.

White wall-mounted boiler with visible flue outlet and, at bottom right,

Recessed or external installation with IPX5D rating

The 25 KIS model can be installed recessed, or externally in partly protected locations with an IPX5D protection rating. The mounting rail is already integrated into the boiler and the power cable is supplied. The hydraulic group has a standard DIN sequence.

Front-access maintenance and flue kit with standard flange

The heat exchanger is accessible from the front for maintenance and cleaning of the combustion chamber. The flue flange is supplied as standard with dedicated flue fittings. The flue kit is available in coaxial or split versions.

Natural gas as standard, LPG with conversion kit

The Riello Start 25 KIS runs on natural gas as standard. Conversion to LPG (G31) and propane air is possible with accessories; the conversion must be carried out by the installer or the authorised service engineer.

Low-consumption circulator, high-head version as an accessory

The circulator is low consumption, IEE 0.20. A 7 m high-head circulator is available as an accessory.

Frequently asked questions

What type of boiler is the Riello Start 25 KIS?
It is a combined condensing boiler (KIS) for heating and domestic hot water, with a domestic hot water output of 25 kW and a seasonal space heating efficiency of 93%.
Does the Riello Start 25 KIS run on natural gas or LPG?
The Riello Start 25 KIS runs on natural gas as standard. Conversion to LPG (G31) and propane air is possible with accessories and must be carried out by the installer or the authorised service engineer.
Can the Riello Start 25 KIS be installed recessed?
The 25 KIS model can be installed recessed, or externally in partly protected locations with an IPX5D protection rating.
Which flue kit is needed with the Riello Start 25 KIS?
The flue kit for the Riello Start 25 KIS is chosen between coaxial and split versions. The flue flange is supplied as standard with dedicated flue fittings.
What is included free with the Riello Start 25 KIS?
The Hi-Comfort T100 programmable thermostat, code 20193354, is included free with the Riello Start 25 KIS.

Technical specifications

Model and codes
ModelRiello Start 25 KIS
Code20187404
Programmable thermostat included freeHi-Comfort T100, Code 20193354
Energy efficiency
Seasonal space heating energy efficiency classA
Water heating energy efficiency classA
Rated output P19 kW
Seasonal space heating energy efficiency93%
Output and performance for heating
Nominal heat input20.00 kW
Nominal heat output (80÷60 °C)19.38 kW
Nominal heat output (50÷30 °C)20.92 kW
Reduced heat input3.10 kW
Reduced heat output (80÷60 °C)2.94 kW
Reduced heat output (50÷30 °C)3.04 kW
Output and performance for domestic hot water
Nominal heat input25.00 kW
Nominal heat output25.00 kW
Reduced heat input3.10 kW
Reduced heat output (*)3.10 kW
Heating operation
Maximum pressure3 bar
Minimum pressure for standard operation0.25 bar
Maximum temperature90 °C
Pump, maximum head available to the system408 mbar
Pump, reference flow rate1000 l/h
Diaphragm expansion vessel8 l
Expansion vessel pre-charge1 bar
Dimensions and weight
Dimensions (H x W x D)780 x 332 x 400 mm
Weight37 kg
Features and equipment
Power supplynatural gas, convertible to LPG (G31) with accessories
Modulation ratio1:8
Electrical protection ratingIPX5D
Flue kitcoaxial or split (option)