The Riello Family HM Connect 35 KIS condensing boiler (Code 20206153) is a wall-mounted, multi-energy natural gas boiler from Riello, for heating and domestic hot water. It delivers 31.2 kW of useful heat output at high-temperature operation, seasonal efficiency of 94%, energy class A+ and noise levels up to 45 dB.

Class A+ with the Hi, Comfort T300 room controller included

The Family HM Connect models come standard with the new Hi, Comfort T300 room controller, which together with the boiler forms a class A+ system. The Family HM Connect is also ready to be integrated into Riello multi-energy systems.

Stainless steel primary heat exchanger and high-efficiency domestic hot water exchanger

The primary heat exchanger is made of corrugated stainless steel. The plate domestic hot water exchanger, condensing and oversized, is developed by Riello and ensures fast reaching of the set point and stable temperature. It produces 20.0 l/min at a ΔT of 25 °C, with a minimum flow rate of 2 l/min.

1:13 modulation with ACC combustion control

The Riello Family HM Connect 35 KIS modulates at a ratio of 1:13, from 32.0 kW down to 2.7 kW heating thermal input. The self-adaptive electronic combustion control ACC (Active Combustion Control) adjusts combustion to maintain high efficiency at different outputs.

3.5-inch touch display with audible confirmation

The Riello Family HM Connect has a 3.5-inch full touch display with icons and multilingual text. The capacitive buttons give audible confirmation (buzzer), and the interface includes a guided tour for the user.

White wall-mounted condensing boiler with circular control panel and colour touch display

NOx class 6, the best under European standards

The boiler is certified NOx class 6, the best emissions class provided for under European standards.

Simplified installation, also suitable for recessed fitting

The Riello Family HM Connect is suitable for recessed installation and has a linear, compact design. The mounting template and power cable are supplied, and the flue flange includes the dedicated flue fittings. The lower connection cover under the boiler is available as an accessory.

Gas: conversion to propane air or LPG via electronic parameter

Gas conversion (propane air, LPG) is selected via an electronic parameter. The model is available in versions with a coaxial or split flue kit.

Frequently asked questions

Is it a natural gas boiler?
Yes, the Riello Family HM Connect 35 KIS runs on natural gas. Conversion to propane air or LPG is set with an electronic parameter.
Can it be installed recessed?
Yes, the Riello Family HM Connect can also be installed recessed. It has an IPX5D electrical protection rating and comes with a power cable and mounting template.
How noisy is the Riello Family HM Connect 35 KIS?
The Riello Family HM Connect 35 KIS has a noise level of up to 45 dB.
Can it be controlled remotely?
Yes, the Riello Family HM Connect has connectivity as standard and allows remote control.
What is needed for the system to achieve class A+?
With the Hi, Comfort T300 room controller, supplied as standard with the Family HM Connect models, the boiler forms a class A+ system.
What are the dimensions and weight of the Riello Family HM Connect boiler?
The Riello Family HM Connect 35 KIS measures 740 x 275 x 420 mm (HxDxW) and weighs 30 kg net.

Technical specifications

Model and codes
ModelRiello Family HM Connect 35 KIS Natural Gas - Complete with Flue Kit
Product code20206153
Flue kitcoaxial or split
Energy efficiency
Seasonal space heating energy efficiency classA / A+ (D / A+++)
Domestic hot water energy efficiency classA / A+ (D / A+++)
Load profileXXL
Rated heat output according to ErP31 kW
Seasonal space heating energy efficiency94% ŋs
Useful efficiency at rated output and high-temperature regime87.8% ŋ4
Useful efficiency at 30% of rated output and low-temperature regime98.8% ŋ1
Annual energy consumption96 GJ
Output and performance
Useful heat output at rated output and high-temperature regime31.2 kW
Useful heat output at 30% of rated output and low-temperature regime10.5 kW
Heating heat input (max-min)32.0-2.7 kW
Nominal domestic hot water heat input (max-min)34.9-2.7 kW
Domestic hot water output at ΔT 25 °C20.0 l/min
Domestic hot water output at ΔT 30 °C16.7 l/min
Domestic hot water output at ΔT 35 °C14.3 l/min
Minimum domestic hot water flow rate2 l/min
NOx class6
Noise
Noise levelup to 45 dB
Installation and connections
Supply voltage230-50 V-Hz
Electrical protection ratingIPX5D
Nominal gas pressure (G20-G31)20-37 mbar
Heating flow-return / gas inlet3/4'' Ø
Domestic hot water inlet-outlet / cylinder flow-return3/4'' Ø
Maximum heating pressure3 bar
Maximum heating temperature90 °C
Diaphragm expansion vessel capacity9 L
Maximum domestic hot water pressure8 bar
Dimensions and weight
Boiler dimensions (HxDxW)740 x 275 x 420 mm
Net weight30 kg
Features and equipment
Featuresconnectivity as standard, Hi, Comfort T300 room controller as standard, hydraulic group with standard DIN sequence, flue flange with dedicated flue fittings
Circulatordigital modulating, 7 m head, low consumption (IEE ≤ 0.20) as standard
Optional accessorieslower connection cover under the boiler, high-head circulator 7.5 m, external sensor