Riello
Condensing Boiler Riello Family 35 KIS Code 20187645 35 kW Natural Gas - Complete with Flue Kit
- Class A
- Natural gas

Couldn't load pickup availability
Shipping and delivery
Shipping and delivery
Timing. With online payment, your order leaves with express courier and arrives within 1-2 working days. In remote areas and on islands, a few extra days may be needed: the estimated delivery date for your postcode is shown under “When it arrives”.
Costs. For orders under €80, shipping costs €8. Delivery to your floor is available for an additional charge.
Availability. Each product shows whether it is in stock, whether only a few units are left, or whether it is sold out; for sold-out products, you can leave your email and we will let you know as soon as they are back in stock.
Your order. You can track it from your account. For any questions, you will find our contact details on the Contact page; all the terms are on the Shipping page.
Support before and after purchase
Support before and after purchase
For advice on choosing a product, a technical question or an order already placed, the Buytutto customer service team is available Monday to Friday, 9:00 am to 1:00 pm and 2:00 pm to 6:00 pm.
You can message us on WhatsApp using the button on this page, or use the contact details on the Contact page. For a product you have already received, open a request from the Support page.
Description
Riello Family 35 KIS (code 20187645) is a condensing boiler running on natural gas, supplied with a flue kit, for heating and domestic hot water. A rating for both heating and hot water, XXL load profile, useful efficiency of 97.4% (80°-60°) and a 10 l expansion vessel.

Coiled stainless steel primary heat exchanger
The primary heat exchanger of the Family is made of coiled stainless steel, designed for efficiency and long-term reliability. The new condensing plate domestic hot water heat exchanger offers top-of-the-class performance in efficiency, temperature stability and waiting times.
ACC combustion control, no commissioning at ignition
The ACC system regulates combustion through a modulating gas valve and an ionisation electrode: it detects excess air and modulates the air/gas mixture. The Family adapts automatically to natural gas or LPG without specific codes or conversion kits: simply select the fuel from the interface if it is not natural gas. By keeping the CO2 produced constant, a flue gas check at ignition is no longer needed for correct operation.
NOx Class 6, the best under European standards
As part of the drive to reduce emissions, the new Family is certified NOx Class 6, the best level provided for under European standards. Thanks to ACC control, emissions remain constant and well below the limits set by regulations.
Colour display and smart system filling function
The colour graphic display constantly shows the operating status of the boiler. Functions are navigated and programmed through an interface with icons and text elements. The panel includes the smart system filling function.
Integration with hybrid systems and RiCLOUD remote control
Thanks to the BUS communication protocol, the Family can communicate with the hybrid control panel and be included in a multi-energy system. It is compatible with the smart RiCLOUD remote control.
Simplified installation and access to components
With the Family, installation and access to components are simplified to minimise time and effort. The boiler comes with a flue flange as standard, with dedicated flue fittings.
The Family range: outputs and versions
The Family range is available in outputs of 25, 30 and 35 kW, in instantaneous combi and heating-only versions. The Riello Family 35 KIS is available with a concentric or twin-pipe flue kit.
Frequently asked questions
Which gases does the Riello Family 35 KIS run on?
Does the Riello Family 35 KIS include a flue kit?
Is combustion commissioning needed at ignition?
Can the Riello Family 35 KIS be integrated into a hybrid system?
What NOx emissions class does the Riello Family 35 KIS have?
What are the dimensions and weight of the Riello Family 35 KIS?
Technical specifications
| Model and codes | |
| Model | Riello Family 35 KIS |
| Code | 20187645 |
| Concentric flue kit variant code | 201876453921 |
| Twin-pipe flue kit variant code | 201876453920 |
| Fuel | natural gas |
| Energy efficiency | |
| Space heating energy class | A |
| Domestic hot water energy class | A |
| Load profile | XXL |
| Nominal heat input | 30.0 kW |
| Nominal heat output (80°-60°) | 29.2 kW |
| Nominal heat output (50°-30°) | 32 kW |
| Reduced heat input | 4.8 kW |
| Reduced heat output (80°-60°) | 4.8 kW |
| Reduced heat output (50°-30°) | 5.1 kW |
| DHW, nominal heat input | 34.6 kW |
| DHW, nominal heat output | 36.3 kW |
| DHW, reduced heat input | 4.9 kW |
| DHW, reduced heat output | 4.5 kW |
| Efficiency and electrical consumption | |
| Useful efficiency (80°-60°) PN MAX - PN MIN | 97.4% |
| Combustion efficiency | 97.7% |
| Useful efficiency (50°-30°) PN MAX - PN MIN | 106.2% |
| Useful efficiency 30% PN MAX (30° return) | 108.4% |
| Total electrical power (Pmax heating) | 84 W |
| Total electrical power (Pmax DHW) | 95 W |
| Technical features | |
| Supply voltage | 230 V - 50 Hz |
| Protection rating | IP X5D |
| Maximum heating pressure | 3 bar |
| Maximum temperature | 90 °C |
| Heating water temperature selection range | 20/45 - 40/80 |
| Expansion vessel | 10 l |
| Maximum DHW operating pressure | 8 bar |
| Dimensions and weight | |
| Boiler dimensions (H x W x D) | 822 x 470 x 350 mm |
| Net boiler weight | 39 kg |
| Features and equipment | |
| Range Rated approval | |
| Modulation ratio | 1:8 |
| Low-consumption modulating circulator | |
| Flue flange supplied as standard with dedicated flue fittings | |
| Can be integrated into hybrid systems | |
| BUS communication protocol | |
| RiCLOUD remote control | |
| NOx emissions class | Class 6 |
| Flue kit | concentric or twin-pipe |