Riello
Condensing Boiler Riello Family 25 KIS Code 20187642 LPG 25 kW + Flue Kit + Programmable Thermostat Hi-Comfort T100 Code 20193354 Free Gift
- 26,3 kW hot water
- Class A
- GPL

Couldn't load pickup availability
Shipping and delivery
Shipping and delivery
Timing. With online payment, your order leaves with express courier and arrives within 1-2 working days. In remote areas and on islands, a few extra days may be needed: the estimated delivery date for your postcode is shown under “When it arrives”.
Costs. For orders under €80, shipping costs €8. Delivery to your floor is available for an additional charge.
Availability. Each product shows whether it is in stock, whether only a few units are left, or whether it is sold out; for sold-out products, you can leave your email and we will let you know as soon as they are back in stock.
Your order. You can track it from your account. For any questions, you will find our contact details on the Contact page; all the terms are on the Shipping page.
Support before and after purchase
Support before and after purchase
For advice on choosing a product, a technical question or an order already placed, the Buytutto customer service team is available Monday to Friday, 9:00 am to 1:00 pm and 2:00 pm to 6:00 pm.
You can message us on WhatsApp using the button on this page, or use the contact details on the Contact page. For a product you have already received, open a request from the Support page.
Description
The Riello Family 25 KIS is a wall-hung condensing boiler for LPG, supplied with a flue gas exhaust kit and the Hi-Comfort T100 room thermostat, code 20193354, as a free gift. For heating and domestic hot water it is class A, with 26.3 kW nominal heat output in domestic hot water, a 97.4% useful efficiency at 80°-60° and a modulation ratio of 1:8.

Wrapped stainless steel primary heat exchanger
The primary heat exchanger of the Riello Family 25 KIS is made of wrapped stainless steel and delivers efficiency and long-term reliability.
Plate condensing domestic hot water heat exchanger
The new plate domestic hot water heat exchanger of the Riello Family 25 KIS is condensing and optimised for stable temperature and shorter waiting times. In domestic hot water mode the boiler reaches a nominal heat output of 26.3 kW and is class A.
ACC combustion control, no calibration for LPG or natural gas
The ACC system of the Riello Family 25 KIS regulates the air/gas mix with the modulating gas valve and the ionisation electrode, even as fuel quality and flue-side pressure losses change. It adapts itself to natural gas or LPG without specific codes or conversion kits: if the gas differs from natural gas, simply select it from the interface. As the CO2 produced is kept constant, no flue gas check is needed at start-up.
Colour display and intelligent system filling
The colour graphic display of the Riello Family 25 KIS shows the boiler's operating status and guides programming with icons and text elements. The new panel includes the intelligent system filling function.
NOx class 6 certified, the best level provided for by European standards
The Riello Family 25 KIS is certified NOx class 6, the highest class provided for by European standards for nitrogen oxide emissions.
BUS protocol, hybrid panel and RiCLOUD remote control
Thanks to the BUS communication protocol, the Riello Family 25 KIS communicates with the hybrid control panel, to be included in a multi-energy system, and with the RiCLOUD intelligent remote control.
Concentric or twin-pipe flue gas exhaust kit
The Riello Family 25 KIS comes with a flue gas exhaust kit, available in concentric and twin-pipe versions. The flue flange is supplied as standard, with a dedicated flue system.
1:8 modulation and low-consumption circulator
The modulation ratio of the Riello Family 25 KIS is 1:8 and the circulator is a low-consumption modulating type. The boiler has Range Rated approval.
Simplified installation
With the Riello Family 25 KIS, installation and access to components are simplified, to reduce time and effort.
Frequently asked questions
What material is the primary heat exchanger of the Riello Family 25 KIS made of?
Does the Riello Family 25 KIS run on LPG without a conversion kit?
How large is the expansion vessel of the Riello Family 25 KIS?
How is the Riello Family 25 KIS connected to the RiCLOUD remote control?
What NOx emissions class does the Riello Family 25 KIS have?
Technical specifications
| Model and codes | |
| Model | Riello Family 25 KIS LPG |
| Model code | 20187642 |
| Flue gas exhaust kit | concentric or twin-pipe |
| Concentric variant code | 20187642_COASS_T100 |
| Twin-pipe variant code | 20187642_SDOPP_T100 |
| GTIN | 8018000401804 |
| Free room thermostat | Hi-Comfort T100 code 20193354 |
| Energy efficiency | |
| Heating energy class | A |
| Domestic hot water energy class | A |
| Load profile | XL |
| Nominal heat input | 20.0 kW |
| Nominal heating output (80°-60°) | 19.5 kW |
| Nominal heating output (50°-30°) | 21.2 kW |
| Reduced heat input | 3.6 kW |
| Reduced heating output (80°-60°) | 3.5 kW |
| Reduced heating output (50°-30°) | 3.8 kW |
| Domestic hot water nominal heat input | 25 kW |
| Domestic hot water nominal output | 26.3 kW |
| Domestic hot water reduced heat input | 3.6 kW |
| Domestic hot water reduced output | 3.3 kW |
| Efficiencies | |
| Useful efficiency (80°-60°) PN max - PN min | 97.4% |
| Combustion efficiency | 97.8% |
| Useful efficiency (50°-30°) PN max - PN min | 106.2% |
| Useful efficiency 30% PN max (30° return) | 108.4% |
| Electricity consumption | |
| Total electrical power (Pmax heating) | 84 W |
| Total electrical power (Pmax domestic hot water) | 95 W |
| Technical specifications | |
| Supply voltage | 230 V - 50 Hz |
| Protection rating | IP X5D |
| Maximum heating pressure | 3 bar |
| Maximum temperature | 90 °C |
| Heating water temperature selection range | 20/45 - 40/80 |
| Expansion vessel | 10 l |
| Maximum domestic hot water pressure | 8 bar |
| Fuel | LPG |
| Dimensions and weight | |
| Boiler dimensions (HxWxD) | 822 x 470 x 275 mm |
| Net boiler weight | 35 kg |
| Features and supply | |
| Primary heat exchanger | wrapped stainless steel |
| Combustion control | ACC |
| Approval | Range Rated |
| Modulation ratio | 1:8 |
| Circulator | low-consumption modulating |
| Flue flange | supplied as standard |
| Emissions | NOx class 6 |
| Communication protocol | BUS |
| Remote control | RiCLOUD |
| Display | colour with intelligent system filling function |
| Integration | hybrid systems |