Skip to content

Description

Ferroli FBC 34C is a wall-mounted condensing boiler for natural gas and LPG, with integrated domestic hot water production. The maximum thermal output for hot water is 34.0 kW and the energy class for heating and hot water is A. It runs on natural gas, LPG and propane-air and can be installed indoors or outdoors in a partially protected location.

White wall-mounted condensing boiler with digital control panel at bottom centre

Stainless steel heat exchanger and 108.8% efficiency at 30%

The heat exchanger is made of stainless steel, with a high-efficiency, low-emission condensing premix system. Efficiency is 97.2-97.0% at 80-60 °C and 105.8-106.9% at 50-30 °C, at maximum and minimum output. At 30% of output the efficiency is 108.8%.

Lower consumption and low emissions

Compared with standard boilers, the FBC 34C consumes less, with a return on investment in the medium term. Polluting emissions are significantly reduced, in line with European regulations.

Natural gas, LPG and propane-air

The boiler runs on natural gas G20, liquid gas G30-G31 and propane-air G230, so it suits both the natural gas network and LPG.

Installation indoors or outdoors

The appliance has a sealed combustion chamber and is suitable for installation indoors or outdoors in a partially protected location, in accordance with EN 15502, with temperatures down to -5 °C. The compact design allows wall-mounted or recessed installation, and the components are accessible for simple maintenance.

Control with digital display and microprocessor

The digital display has an intuitive interface for controlling temperature, mode and diagnostics. The control system is microprocessor-based.

Coaxial or split flue gas kit

The boiler is supplied complete with a flue gas kit, available in coaxial or split version among the product options.

Frequently asked questions

Which gases can the Ferroli FBC 34C use?
The Ferroli FBC 34C runs on natural gas G20, liquid gas G30-G31 and propane-air G230.
Can the Ferroli FBC 34C be installed outdoors?
Yes, the Ferroli FBC 34C is suitable for installation indoors or outdoors in a partially protected location, in accordance with EN 15502, with temperatures down to -5 °C.
What is the efficiency of the Ferroli FBC 34C?
The Ferroli FBC 34C has an efficiency of 97.2-97.0% at 80-60 °C at maximum and minimum output, and 108.8% at 30% of output.
Does the Ferroli FBC 34C also produce domestic hot water?
Yes, the Ferroli FBC 34C has integrated domestic hot water production, with a maximum domestic hot water thermal output of 34.0 kW.
How is the Ferroli FBC 34C controlled?
The Ferroli FBC 34C is controlled by a digital display with an intuitive interface for temperature, mode and diagnostics, managed by a microprocessor system.
What operating pressures does the Ferroli FBC 34C have?
For heating, the Ferroli FBC 34C operates between a maximum of 3 bar and a minimum of 0.8 bar; for hot water the values are 9 and 0.3.

Technical specifications

Model and codes
ModelFerroli FBC 34C
Product code0TPF7AWT
Power and performance
Max heating thermal input30.7 kW
Min heating thermal input6.0 kW
Heating thermal input (80/60 °C) max30.0 kW
Heating thermal input (80/60 °C) min6.0 kW
Heating thermal input (50/30 °C) max32.0 kW
Heating thermal input (50/30 °C) min6.4 kW
DHW thermal input (Hi) max34.8 kW
DHW thermal input (Hi) min6.4 kW
Max DHW thermal output34.0 kW
Min DHW thermal output5.5 kW
DHW flow at 25 °C19 l/min
DHW flow at 30 °C16 l/min
Max heating operating pressure3 bar
Min heating operating pressure0.8 bar
Max DHW operating pressure9
Min DHW operating pressure0.3
Energy efficiency
Efficiency at max output (80-60 °C)97.2%
Efficiency at min output (80-60 °C)97.0%
Efficiency at max output (50-30 °C)105.8%
Efficiency at min output (50-30 °C)106.9%
Efficiency at 30%108.8%
Heating and DHW energy classA
Dimensions and weight
Empty weight31 kg
Dimensions W x H x D420 x 700 x 250 mm
Functions and equipment
Functionsintegrated DHW production, microprocessor control system, digital display
Installationindoors or outdoors in a partially protected location, per EN 15502
Installation temperaturedown to -5 °C
Gasnatural gas G20, liquid gas G30-G31, propane-air G230