Ferroli
Ferroli Model BLUEHELIX HITECH RRT 28 K 50 With 50-Litre Storage Tank, Natural Gas/LPG 28 kW Cod. 0T4T4AWA - Complete with Flue Gas Exhaust Kit
- Class A

Couldn't load pickup availability
Shipping and delivery
Shipping and delivery
Timing. With online payment, your order leaves with express courier and arrives within 1-2 working days. In remote areas and on islands, a few extra days may be needed: the estimated delivery date for your postcode is shown under “When it arrives”.
Costs. For orders under €80, shipping costs €8. Delivery to your floor is available for an additional charge.
Availability. Each product shows whether it is in stock, whether only a few units are left, or whether it is sold out; for sold-out products, you can leave your email and we will let you know as soon as they are back in stock.
Your order. You can track it from your account. For any questions, you will find our contact details on the Contact page; all the terms are on the Shipping page.
Support before and after purchase
Support before and after purchase
For advice on choosing a product, a technical question or an order already placed, the Buytutto customer service team is available Monday to Friday, 9:00 am to 1:00 pm and 2:00 pm to 6:00 pm.
You can message us on WhatsApp using the button on this page, or use the contact details on the Contact page. For a product you have already received, open a request from the Support page.
Description
Ferroli BlueHelix Hitech RRT 28 K 50 is a wall-mounted condensing boiler for space heating and domestic hot water, with a 50-litre storage cylinder and natural gas operation. Heating thermal output ranges from 3.4 to 24.0 kW, with useful thermal efficiency up to 98.1% at maximum output (80°C-60°C), class A for heating and domestic hot water.

Stainless steel primary heat exchanger with enlarged passages
The primary heat exchanger is made of stainless steel, with high thickness and enlarged passages, among the best in its category. It ensures durability and reduced maintenance, and the boiler maintains high efficiency even on older systems with oxidation and dirt.
A+System: class A+ with remote control and outdoor sensor
Combined with the modulating remote control and the outdoor sensor, both optional, the boiler reaches the higher efficiency class A+ on the scale from G to A+++. With the outdoor sensor, operation uses sliding temperature control.
MC2 Multi Combustion Control: combustion that adapts to the gas
MC2 is the combustion system with patented gas-adaptive technology derived from industrial applications. It adapts to variations in the gas network, such as fluctuations or reduced pressures.

Modulation up to 1:10
The modulation range can reach up to 1:10 (model 34), to match the load required by the system.
Natural gas, LPG and propane air
Operation on LPG is certified with the dedicated kit, to be requested. Conversion between natural gas, LPG and propane air is free during the initial inspection of the product and warranty activation, to be requested from the Authorised Service Centre.
F.P.S. flue protection and 50 mm flue outlet
The standard flue clapet valve, F.P.S. (Flue Protection System), allows easy connection to pressurised collective flue systems, for example in renovations, in accordance with standard UNI 7129. The boiler is approved for operation with 50 mm diameter flue outlets, including chimney flues that require heavy lining.
Domestic hot water with 50-litre stainless steel storage
Domestic hot water is produced by a 50-litre stainless steel storage cylinder. The anti-legionella function has a programmable timer from 1 to 7 days.
Easier maintenance with self-cooling door
The heat exchanger-burner with self-cooling door simplifies maintenance and reduces its cost, thanks to fewer parts to replace. The boiler is designed to make routine maintenance and cleaning operations easier.
Circulator and three-way valve protected by anti-seizure function
The timed anti-seizure function protects the circulator and the three-way valve. The by-pass is standard.
Outdoor installation in a partially protected location
The boiler can also be installed outdoors in a partially protected location, with protection down to -5 °C as standard. The hydraulic connections are covered by the casing and prepared for recirculation with the connection kit.
Range Rated: output matched to system demand
The generator is certified Range Rated: the maximum heating thermal output can be adjusted to the system's heat demand, while maintaining the efficiency values declared in certification.
Frequently asked questions
What is needed to run the Ferroli BlueHelix Hitech RRT 28 K 50 on LPG?
What does A+System mean on the Ferroli BlueHelix Hitech RRT 28 K 50?
How much hot water does the Ferroli BlueHelix Hitech RRT 28 K 50 storage cylinder hold?
How does the anti-legionella function of the Ferroli BlueHelix Hitech RRT 28 K 50 work?
Can the Ferroli BlueHelix Hitech RRT 28 K 50 be installed outdoors?
What is the F.P.S. flue protection of the Ferroli BlueHelix Hitech RRT 28 K 50?
Technical specifications
| Model and codes | |
| Model | Ferroli BlueHelix Hitech RRT 28 K 50 |
| Product code (natural gas) | 0T4T4AWA |
| Code (coaxial flue gas kit) | 5016341011168 |
| Code (split flue gas kit) | 5016341011167 |
| Output and performance | |
| Heating thermal input min/max (kW) | 3.5 / 24.5 |
| Domestic hot water thermal input (kW) | 28.5 |
| Heating thermal output min/max (kW) | 3.4 / 24.0 |
| Maximum thermal output (kW) | 28 |
| Useful thermal efficiency 80°C-60°C, Pmax (%) | 98.1 |
| Useful thermal efficiency 80°C-60°C, Pmin (%) | 98.0 |
| NOx class | 6 |
| Energy efficiency | |
| Heating efficiency class | A |
| Domestic hot water efficiency class | A |
| A+System | class A+ with modulating remote control and outdoor sensor (optional), scale from G to A+++ |
| Hot water and storage | |
| Storage cylinder capacity (litres) | 50 |
| Storage material | stainless steel |
| Dimensions and installation | |
| Dimensions H x W x D (mm) | 807 x 600 x 434 |
| Installation location | including outdoors in a partially protected location down to -5 °C as standard |
| Hydraulic connections | covered by the casing; prepared for recirculation connections |
| Flue outlet | approved for 50 mm diameter |
| Fuel | |
| Fuel | Natural gas |
| Fuel with kit | LPG |
| Functions and equipment | |
| Functions | M.G.R. Natural gas, LPG, propane air Ready; MC2 Multi Combustion Control; F.P.S. Flue Protection System; anti-legionella function programmable from 1 to 7 days; timed anti-seizure function for circulator and three-way valve; temperature-sliding operation with optional outdoor sensor; by-pass as standard; self-cooling door; Range Rated generator |