Ferroli
Ferroli Bluehelix Alpha 28C Condensing Boiler, Natural Gas 28 kW Cod. 0TPF4AWA - Complete with Flue Gas Exhaust Kit
- 28 kW hot water
- 14 litres per minute
- Class A
- Natural gas

Couldn't load pickup availability
Shipping and delivery
Shipping and delivery
Timing. With online payment, your order leaves with express courier and arrives within 1-2 working days. In remote areas and on islands, a few extra days may be needed: the estimated delivery date for your postcode is shown under “When it arrives”.
Costs. For orders under €80, shipping costs €8. Delivery to your floor is available for an additional charge.
Availability. Each product shows whether it is in stock, whether only a few units are left, or whether it is sold out; for sold-out products, you can leave your email and we will let you know as soon as they are back in stock.
Your order. You can track it from your account. For any questions, you will find our contact details on the Contact page; all the terms are on the Shipping page.
Support before and after purchase
Support before and after purchase
For advice on choosing a product, a technical question or an order already placed, the Buytutto customer service team is available Monday to Friday, 9:00 am to 1:00 pm and 2:00 pm to 6:00 pm.
You can message us on WhatsApp using the button on this page, or use the contact details on the Contact page. For a product you have already received, open a request from the Support page.
Description
The Ferroli Bluehelix Alpha 28C is a 28 kW wall-mounted condensing boiler for methane, with flue gas kit included in the selected version, for heating and instant domestic hot water production. It has a single-circuit stainless steel primary heat exchanger with no joints or welds, which maintains high efficiency even on older systems, and a domestic hot water flow rate of 14 l/min with Δt 25 °C. Class A for heating and class A for domestic hot water (XL profile) complete the boiler's rating.

Seamless stainless steel heat exchanger
The stainless steel primary heat exchanger is single-circuit and free of joints and/or welds. The domestic hot water exchanger is a dedicated plate type, and enables instant domestic hot water production.
MC2 and gas management: methane, LPG and propane air
The MC2 Multi Combustion Control system uses patented gas-adaptive technology of industrial origin, to adapt to variations in the gas network (e.g. fluctuations or reduced pressures). The M.G.R. function (Methane, LPG, Propane air Ready) allows the boiler to run on methane, LPG and propane air with simple configuration, without additional conversion kits. Free conversion during the initial inspection is requested from the Authorised Service Centre.
Flue gas exhaust and installation
The flue gas exhaust kit is included in the selected version. With the optional gas exhaust clapet valve kit (041106X0), which can be installed outside the boiler, connection to pressurised collective flue systems (e.g. in refurbishments) is possible, in accordance with UNI 7129 standards. The kit cannot be used in built-in installations. The degree of protection is IPX4D.

Outdoor installation in a partially protected location down to -5 °C as standard, and down to -15 °C with the optional anti-freeze heater kit. When the temperature inside the boiler drops to 5 °C, the burner and circulator switch on automatically to protect the appliance from freezing, provided the boiler is connected to the gas supply and to the electrical mains.
Easy maintenance

The electrical box of the control board can be removed from the chassis, leaving the internal parts accessible. The burner assembly is accessible by removing 4 screws and the fan's quick-release clip. The domestic water inlet filter can be removed from inside without removing the hydraulic connections. The plate heat exchanger is replaced by removing two Allen bolts accessible from the front. The casing, removable in 3 parts, simplifies maintenance.
SUN EASY function for solar systems
The solar system readiness allows the boiler to be combined with thermosiphon or forced-circulation solar panels. A sensor on the domestic hot water circuit monitors the temperature of the water pre-heated by the panels and only switches on the burner if it falls below the level needed for user comfort.

STOP AND GO function
The Stop and Go parameter delays the burner ignition, which only activates when hot water is actually drawn. It prevents false starts caused by short draws for rinsing, which can reduce the product's average service life.
ECO-COMFORT domestic hot water function
In ECO mode, domestic hot water is produced to standard levels, with energy savings during periods of non-use. In COMFORT mode, the heat exchanger temperature-maintenance system makes delivery faster and more comfortable. The load profile is XL, class A.
Frequently asked questions
What material is the primary heat exchanger of the Ferroli Bluehelix Alpha 28C made from?
Does the Ferroli Bluehelix Alpha 28C also run on LPG?
Can the Ferroli Bluehelix Alpha 28C be installed outdoors?
What domestic hot water flow rate does the Ferroli Bluehelix Alpha 28C provide?
Is the Ferroli Bluehelix Alpha 28C compatible with solar systems?
How is the Ferroli Bluehelix Alpha 28C maintained?
Technical specifications
| Model and codes | |
| Model | Ferroli Bluehelix Alpha 28C Condensing Boiler for Methane, Complete with Flue Gas Exhaust Kit |
| Product code | 0TPF4AWA |
| Coaxial variant SKU code | 0TPF4AWA8029 |
| Split variant SKU code | 0TPF4AWA8028 |
| Energy efficiency | |
| Heating energy efficiency | Class A |
| Domestic hot water energy efficiency | XL profile, Class A |
| Power and performance | |
| Max heating heat input (Hs) | 27.2 kW |
| Min heating heat input (Hs) | 5.3 kW |
| Max domestic hot water heat input (Hi) | 28 kW |
| Max heating operating pressure | 3 bar |
| Min heating operating pressure | 0.8 bar |
| Heating expansion vessel capacity | 8 litres |
| Max domestic hot water operating pressure | 9 bar |
| Min domestic hot water operating pressure | 0.3 bar |
| Domestic hot water flow rate Δt 25 °C | 14 l/min |
| Degree of protection (IEC 60529) | IPX4D |
| Power supply | |
| Supply voltage | 230 V / 50 Hz |
| Fuel | methane |
| Dimensions | |
| Dimensions H x W x D | 700 x 420 x 250 mm |
| Functions and equipment | |
| Functions | MC2 Multi Combustion Control, M.G.R., solar system readiness, sliding temperature operation with optional external sensor, low-consumption modulating circulator (ErP Ready, Class A), digital flame control with three re-ignition attempts, standard by-pass, interface with display and multifunction keys, hydraulic connections concealed by the casing, SUN EASY function, STOP AND GO function, anti-freeze function, ECO-COMFORT domestic hot water function |
| Flue gas exhaust kit | coaxial or split (option) |


