Skip to content

Description

The Ferroli Bluehelix Alpha 28C is a 28 kW wall-mounted condensing boiler for methane, with flue gas kit included in the selected version, for heating and instant domestic hot water production. It has a single-circuit stainless steel primary heat exchanger with no joints or welds, which maintains high efficiency even on older systems, and a domestic hot water flow rate of 14 l/min with Δt 25 °C. Class A for heating and class A for domestic hot water (XL profile) complete the boiler's rating.

White wall-mounted boiler with black control panel and the Ferroli logo on the front

Seamless stainless steel heat exchanger

The stainless steel primary heat exchanger is single-circuit and free of joints and/or welds. The domestic hot water exchanger is a dedicated plate type, and enables instant domestic hot water production.

MC2 and gas management: methane, LPG and propane air

The MC2 Multi Combustion Control system uses patented gas-adaptive technology of industrial origin, to adapt to variations in the gas network (e.g. fluctuations or reduced pressures). The M.G.R. function (Methane, LPG, Propane air Ready) allows the boiler to run on methane, LPG and propane air with simple configuration, without additional conversion kits. Free conversion during the initial inspection is requested from the Authorised Service Centre.

Flue gas exhaust and installation

The flue gas exhaust kit is included in the selected version. With the optional gas exhaust clapet valve kit (041106X0), which can be installed outside the boiler, connection to pressurised collective flue systems (e.g. in refurbishments) is possible, in accordance with UNI 7129 standards. The kit cannot be used in built-in installations. The degree of protection is IPX4D.

Pictograms illustrating boiler functions: frost protection, weather compensation, pre-heating

Outdoor installation in a partially protected location down to -5 °C as standard, and down to -15 °C with the optional anti-freeze heater kit. When the temperature inside the boiler drops to 5 °C, the burner and circulator switch on automatically to protect the appliance from freezing, provided the boiler is connected to the gas supply and to the electrical mains.

Easy maintenance

Three views of a boiler combustion chamber: the stainless steel coil heat exchanger

The electrical box of the control board can be removed from the chassis, leaving the internal parts accessible. The burner assembly is accessible by removing 4 screws and the fan's quick-release clip. The domestic water inlet filter can be removed from inside without removing the hydraulic connections. The plate heat exchanger is replaced by removing two Allen bolts accessible from the front. The casing, removable in 3 parts, simplifies maintenance.

SUN EASY function for solar systems

The solar system readiness allows the boiler to be combined with thermosiphon or forced-circulation solar panels. A sensor on the domestic hot water circuit monitors the temperature of the water pre-heated by the panels and only switches on the burner if it falls below the level needed for user comfort.

Diagram of a solar thermal panel system

STOP AND GO function

The Stop and Go parameter delays the burner ignition, which only activates when hot water is actually drawn. It prevents false starts caused by short draws for rinsing, which can reduce the product's average service life.

ECO-COMFORT domestic hot water function

In ECO mode, domestic hot water is produced to standard levels, with energy savings during periods of non-use. In COMFORT mode, the heat exchanger temperature-maintenance system makes delivery faster and more comfortable. The load profile is XL, class A.

Frequently asked questions

What material is the primary heat exchanger of the Ferroli Bluehelix Alpha 28C made from?
The primary heat exchanger of the Ferroli Bluehelix Alpha 28C is made of stainless steel, single-circuit and free of joints and/or welds.
Does the Ferroli Bluehelix Alpha 28C also run on LPG?
Yes, the Ferroli Bluehelix Alpha 28C is M.G.R. ready (Methane, LPG, propane air) and runs on methane, LPG and propane air without additional conversion kits.
Can the Ferroli Bluehelix Alpha 28C be installed outdoors?
The Ferroli Bluehelix Alpha 28C can be installed in a partially protected location down to -5 °C as standard, and down to -15 °C with the optional anti-freeze heater kit.
What domestic hot water flow rate does the Ferroli Bluehelix Alpha 28C provide?
The Ferroli Bluehelix Alpha 28C has a domestic hot water flow rate of 14 l/min with Δt 25 °C.
Is the Ferroli Bluehelix Alpha 28C compatible with solar systems?
Yes, the Ferroli Bluehelix Alpha 28C is designed to produce domestic hot water combined with solar panels, using the SUN EASY function.
How is the Ferroli Bluehelix Alpha 28C maintained?
On the Ferroli Bluehelix Alpha 28C, the electrical box can be removed from the chassis, the domestic water filter can be removed from inside, and the plate heat exchanger is replaced by removing two Allen bolts.

Technical specifications

Model and codes
ModelFerroli Bluehelix Alpha 28C Condensing Boiler for Methane, Complete with Flue Gas Exhaust Kit
Product code0TPF4AWA
Coaxial variant SKU code0TPF4AWA8029
Split variant SKU code0TPF4AWA8028
Energy efficiency
Heating energy efficiencyClass A
Domestic hot water energy efficiencyXL profile, Class A
Power and performance
Max heating heat input (Hs)27.2 kW
Min heating heat input (Hs)5.3 kW
Max domestic hot water heat input (Hi)28 kW
Max heating operating pressure3 bar
Min heating operating pressure0.8 bar
Heating expansion vessel capacity8 litres
Max domestic hot water operating pressure9 bar
Min domestic hot water operating pressure0.3 bar
Domestic hot water flow rate Δt 25 °C14 l/min
Degree of protection (IEC 60529)IPX4D
Power supply
Supply voltage230 V / 50 Hz
Fuelmethane
Dimensions
Dimensions H x W x D700 x 420 x 250 mm
Functions and equipment
FunctionsMC2 Multi Combustion Control, M.G.R., solar system readiness, sliding temperature operation with optional external sensor, low-consumption modulating circulator (ErP Ready, Class A), digital flame control with three re-ignition attempts, standard by-pass, interface with display and multifunction keys, hydraulic connections concealed by the casing, SUN EASY function, STOP AND GO function, anti-freeze function, ECO-COMFORT domestic hot water function
Flue gas exhaust kitcoaxial or split (option)