Daikin
Condensing Boiler Daikin Model D2CND 28 KW with Flue Kit - NEW ERP
Condensing Boiler Daikin Model D2CND 28 KW with Flue Kit - NEW ERP
- Class A

Couldn't load pickup availability
Shipping and delivery
Shipping and delivery
Timing. With online payment, your order leaves with express courier and arrives within 1-2 working days. In remote areas and on islands, a few extra days may be needed: the estimated delivery date for your postcode is shown under “When it arrives”.
Costs. For orders under €80, shipping costs €8. Delivery to your floor is available for an additional charge.
Availability. Each product shows whether it is in stock, whether only a few units are left, or whether it is sold out; for sold-out products, you can leave your email and we will let you know as soon as they are back in stock.
Your order. You can track it from your account. For any questions, you will find our contact details on the Contact page; all the terms are on the Shipping page.
Support before and after purchase
Support before and after purchase
For advice on choosing a product, a technical question or an order already placed, the Buytutto customer service team is available Monday to Friday, 9:00 am to 1:00 pm and 2:00 pm to 6:00 pm.
You can message us on WhatsApp using the button on this page, or use the contact details on the Contact page. For a product you have already received, open a request from the Support page.
Description
The Daikin D2CND 28 kW is a wall-hung natural gas condensing boiler with flue kit included, for heating and instantaneous domestic hot water. It has class A heating efficiency, efficiency up to 108.7%, 1:4 modulation and a 10 l expansion vessel. The flue kit is available in coaxial or split versions.
Heating efficiency up to 108.7% with Eco Mode
The Daikin D2CND 28 kW has a nominal heating output of 4.6 to 26.8 kW at 80/60 °C and 5.2 to 28.0 kW at 50/30 °C. The Eco Mode function controls the return temperature and targets 35 °C to maximise condensation and heating efficiency.
Ready hot water with Warm Start
The Warm Start function keeps the body of the plate heat exchanger warm, so domestic hot water arrives straight away with reduced waiting times. Continuous-flow output is 14 l/min at ΔT 30 °C and 16.8 l/min at ΔT 25 °C, with class A efficiency on the XL draw-off profile, across a temperature range of 35 to 60 °C.

Solar hot water pre-heating
With the solar connection, if the water entering the boiler is already pre-heated by the solar system, the burner does not ignite, for optimal use of the solar source.
Compact water/flue gas heat exchanger and SCOT-regulated combustion
The ultra-compact water/flue gas heat exchanger is Daikin patented and reduces size and weight. The SCOT system regulates combustion and adapts automatically to the gas quality, natural gas or LPG, for clean combustion and minimal polluting emissions.

Daikin Eye shows operating status
The Daikin Eye is a multicolour LED that shows the boiler's operating status. In the event of a fault the LED turns red and the error code appears.

Flexible installation with IP X5D protection rating
With an IP X5D protection rating, the Daikin D2CND 28 kW can be installed indoors and also outside the home. The flue kit is included, in coaxial or split versions.
Frequently asked questions
Which systems is the Daikin D2CND 28 kW suitable for?
Can the Daikin D2CND 28 kW be installed outdoors?
What is the maximum flue length for the Daikin D2CND 28 kW?
How much hot water does the Daikin D2CND 28 kW deliver?
What does the Daikin Eye on the Daikin D2CND 28 kW indicate?
How heavy and how tall is the Daikin D2CND 28 kW?
Technical specifications
| Model and codes | |
| Model | Daikin D2CND 28 kW |
| Label | NEW ErP |
| Coaxial flue kit | code D2CND1178 |
| Split flue kit | code D2CND1179 |
| Energy efficiency | |
| Heating efficiency class (55°C) | A |
| Burner input (Qn) | 4.8 to 27.5 kW |
| Nominal heating output (80/60 °C) | 4.6 to 26.8 kW |
| Nominal heating output (50/30 °C) | 5.2 to 28.0 kW |
| Heating efficiency | up to 108.7% |
| Modulation range | 1:4 |
| Expansion vessel volume | 10 l |
| Domestic hot water | |
| Efficiency class on draw-off profile | A (XL) |
| Minimum temperature | 35 °C |
| Maximum temperature | 60 °C |
| Continuous-flow output (ΔT 30 °C) | 14 l/min |
| Continuous-flow output (ΔT 25 °C) | 16.8 l/min |
| Maximum water mains pressure | 10 bar |
| Minimum water mains pressure | 0.5 bar |
| Water content | 1.31 l |
| Noise | |
| Sound power | 49 dB |
| Sound pressure at 1 m | 39 dB |
| Power supply and emissions | |
| Fuel | natural gas |
| Supply voltage | 230 V |
| Frequency | 50 Hz |
| Maximum electrical power input | 86 W |
| Standby electrical power | 3.5 W |
| Electrical protection class | IP X5D |
| NOx class | 6 |
| Flue gas temperature (G20) | 77 °C |
| Flue gas discharge | |
| Flue duct diameter | 60/100 mm |
| Maximum flue length DN 60/100 | 12.5 m |
| Maximum flue length DN 80/125 | 42.8 m |
| Maximum flue length DN 80/80 | 125 m |
| Flue connection in kit | SB.D2CND024A0 |
| Dimensions and weight | |
| Dimensions (H x W x D) | 695 x 440 x 295 mm |
| Weight | 37 kg |