Chaffoteaux Condensing Boiler with Niagara Advance 35 kW Storage Tank, Natural Gas/LPG, Code 3310627 - Complete with Flue Kit
Chaffoteaux Condensing Boiler with Niagara Advance 35 kW Storage Tank, Natural Gas/LPG, Code 3310627 - Complete with Flue Kit
- 30,2 kW heating
- 33,1 kW hot water
- 19,8 litres per minute
- Class A+

Couldn't load pickup availability
Shipping and delivery
Shipping and delivery
Timing. With online payment, your order leaves with express courier and arrives within 1-2 working days. In remote areas and on islands, a few extra days may be needed: the estimated delivery date for your postcode is shown under “When it arrives”.
Costs. For orders under €80, shipping costs €8. Delivery to your floor is available for an additional charge.
Availability. Each product shows whether it is in stock, whether only a few units are left, or whether it is sold out; for sold-out products, you can leave your email and we will let you know as soon as they are back in stock.
Your order. You can track it from your account. For any questions, you will find our contact details on the Contact page; all the terms are on the Shipping page.
Support before and after purchase
Support before and after purchase
For advice on choosing a product, a technical question or an order already placed, the Buytutto customer service team is available Monday to Friday, 9:00 am to 1:00 pm and 2:00 pm to 6:00 pm.
You can message us on WhatsApp using the button on this page, or use the contact details on the Contact page. For a product you have already received, open a request from the Support page.
Description
The condensing boiler Chaffoteaux Niagara Advance (code 3310627) is a wall-hung boiler for heating and domestic hot water with 30.2 kW maximum useful output in heating (80-60 °C) and 40 litres of domestic hot water reserve from two 20-litre cylinders. It runs on natural gas and LPG and is available with a coaxial or split flue kit.

Domestic hot water from two 20-litre cylinders
Two stratified stainless steel storage tanks provide a 40-litre reserve. With the storage tanks emptied, domestic hot water remains available. The flow rate reaches 19.8 l/min at ΔT 25 °C and 14.1 l/min at ΔT 35 °C, with three-star domestic hot water performance according to EN 13203, the maximum level provided.
Single-coil heat exchanger and 94% seasonal efficiency
The new stainless steel primary heat exchanger has a single coil, with passage sections increased by 142% compared with the previous version and 1 m more head. The declared seasonal efficiency is 94%, with class A+ achievable with heating control. Performance is certified by the TÜV RHEINLAND Group.
1:10 modulation and internal silencer
The modulation ratio is 1:10, with useful output from 3.3 kW to 30.2 kW in heating (80-60 °C). The internal silencer is optimised and the Niagara Advance includes the SRA function.
Gas: natural gas or LPG selectable from the technical menu
The gas type is selected from the technical menu, thanks to combustion control. The gas conversion kit is included as standard. The boiler is prepared for Chaffolink connectivity.
Installation: flue outlets of 80, 60 and 50 mm
The Niagara Advance is intended for partially protected locations. Flue outlets are 80, 60 and 50 mm and electrical connections are designed to be intuitive.
Frequently asked questions
Does it run on both natural gas and LPG?
How much hot water can the Niagara Advance supply?
Which flue diameters does the Niagara Advance accept?
What is the seasonal efficiency of the Niagara Advance?
What changes with the new primary heat exchanger?
Can the Niagara Advance be installed outdoors?
Technical specifications
| Model and codes | |
| Model | Chaffoteaux Niagara Advance 35 kW |
| Product code | 3310627 |
| Coaxial kit variant code | 33106274454 |
| Split kit variant code | 33106274453 |
| Flue kit | coaxial, split |
| Power and performance | |
| Heating heat input max (Hi) | 31 kW |
| Heating heat input min (Hi) | 3.5 kW |
| Heating heat input max (Hs) | 34.4 kW |
| Heating heat input min (Hs) | 3.9 kW |
| Domestic hot water heat input max (Hi) | 34.5 kW |
| Domestic hot water heat input min (Hi) | 3.5 kW |
| Domestic hot water heat input max (Hs) | 38.3 kW |
| Domestic hot water heat input min (Hs) | 3.9 kW |
| Heating useful output max (80-60 °C) | 30.2 kW |
| Heating useful output min (80-60 °C) | 3.3 kW |
| Heating useful output max (50-30 °C) | 33.1 kW |
| Heating useful output min (50-30 °C) | 3.7 kW |
| Domestic hot water useful output max | 33.1 kW |
| Domestic hot water useful output min | 3.4 kW |
| Energy efficiency | |
| Combustion efficiency (flue gas) | 97.9 % |
| Efficiency at nominal rate (60/80 °C) Hi/Hs | 97.5 / 87.8 % |
| Efficiency at nominal rate (30/50 °C) Hi/Hs | 106.9 / 96.3 % |
| Efficiency at 30% of Qn with 30 °C return Hi/Hs | 109.6 / 98.7 % |
| Efficiency at minimum (60/80 °C) Hi/Hs | 93.3 / 84.0 % |
| Efficiency stars (dir. 92/42/EEC) | **** |
| Domestic hot water comfort stars (EN 13203) | *** |
| Circulator energy efficiency index EEI | ≤ 0.23 |
| Emissions and flue gas | |
| NOx class | 6 |
| Flue gas temperature (G20) 80-60 °C | 62 °C |
| CO2 content (G20) 80-60 °C | 8.8 % |
| CO content (0% O2) 80-60 °C | 111 ppm |
| O2 content (G20) 80-60 °C | 4.3 % |
| Maximum flue gas flow (G20) 80-60 °C | 56.3 kg/h |
| Excess air 80-60 °C | 26 % |
| Condensate pH | 3.2 |
| Maximum condensate quantity | 3.7 l/h |
| Flue outlets | 80, 60, 50 mm |
| Heating circuit | |
| Expansion vessel precharge pressure | 1 bar |
| Maximum heating pressure | 3 bar |
| Expansion vessel capacity | 8 l |
| Heating temperature min/max (high temperature) | 35 / 82 °C |
| Heating temperature min/max (low temperature) | 20 / 45 °C |
| Domestic hot water circuit | |
| Domestic hot water temperature min/max | 40 / 65 °C |
| Specific domestic hot water flow (10 min, ΔT 30 °C) | 16.5 l/min |
| Instantaneous hot water quantity ΔT 25 °C | 19.8 l/min |
| Instantaneous hot water quantity ΔT 35 °C | 14.1 l/min |
| Minimum hot water draw-off | 2 l/min |
| Domestic water pressure max/min | 7.0 / 0.3 bar |
| DHW storage capacity | 40 l |
| Integrated domestic expansion vessel | 2 l |
| Power supply and installation | |
| Fuel | Natural gas, LPG |
| Supply voltage/frequency | 230 V / 50 Hz |
| Total electrical power absorbed | 84.7 W |
| Electrical system protection rating | IP X5D |
| Installation | partially protected locations |
| Dimensions and weight | |
| Dimensions (height x width x depth) | 900 x 600 x 460 mm |
| Weight | 46 kg |