Chaffoteaux
Condensing Boiler with Storage Tank Chaffoteaux Niagara Advance 25 Kw Natural Gas/LPG Code 3310626 - Complete with Flue Kit
Condensing Boiler with Storage Tank Chaffoteaux Niagara Advance 25 Kw Natural Gas/LPG Code 3310626 - Complete with Flue Kit
- 24,9 kW hot water
- Class A+

Couldn't load pickup availability
Shipping and delivery
Shipping and delivery
Timing. With online payment, your order leaves with express courier and arrives within 1-2 working days. In remote areas and on islands, a few extra days may be needed: the estimated delivery date for your postcode is shown under “When it arrives”.
Costs. For orders under €80, shipping costs €8. Delivery to your floor is available for an additional charge.
Availability. Each product shows whether it is in stock, whether only a few units are left, or whether it is sold out; for sold-out products, you can leave your email and we will let you know as soon as they are back in stock.
Your order. You can track it from your account. For any questions, you will find our contact details on the Contact page; all the terms are on the Shipping page.
Support before and after purchase
Support before and after purchase
For advice on choosing a product, a technical question or an order already placed, the Buytutto customer service team is available Monday to Friday, 9:00 am to 1:00 pm and 2:00 pm to 6:00 pm.
You can message us on WhatsApp using the button on this page, or use the contact details on the Contact page. For a product you have already received, open a request from the Support page.
Description
Chaffoteaux Niagara Advance (code 3310626) is a wall-mounted condensing boiler with a 40-litre domestic hot water storage, made up of two 20-litre stainless steel storage tanks. It runs on natural gas and LPG without needing a kit and has a seasonal efficiency of 94%. It is designed for the most demanding domestic hot water needs.

Single-coil stainless steel primary heat exchanger
The Niagara Advance primary heat exchanger is single-coil stainless steel. Compared with the previous version, the passage sections are increased by 142% and the head is 1 m higher.
Two stratified storage tanks for 40 litres of hot water
The 40-litre reserve is provided by two stratified stainless steel storage tanks. Domestic hot water is still available even when the storage tanks are empty. The flow rate reaches up to 19.8 l/min with ΔT 25 °C, and domestic hot water performance is 3 stars (***), the maximum level set by the EN 13203 standard. The integrated domestic hot water expansion vessel is 2 litres.
1:10 modulation and optimised internal silencer
The Niagara Advance modulation ratio is 1:10. The internal silencer is optimised, and the boiler has the SRA function.
Class A+ with temperature control and TÜV Rheinland certified performance
The Niagara Advance achieves Class A+ with temperature control. Its performance is certified by TÜV RHEINLAND Group.
Installation in partially protected locations
The boiler is installed in partially protected locations. Flue outlets are 80, 60 and 50 mm and the electrical connections are intuitive.
Frequently asked questions
Does the Chaffoteaux Niagara Advance run on LPG?
How much domestic hot water does the Niagara Advance offer?
What is the modulation ratio of the Niagara Advance?
Can the Niagara Advance be installed in protected locations?
Is the Niagara Advance ready for connected control?
Technical specifications
| Model and codes | |
| Product code | 3310626 |
| Flue kit | concentric or split |
| Energy efficiency | |
| Nominal heat input heating maximum (Hi) | 22 kW |
| Nominal heat input heating minimum (Hi) | 2.5 kW |
| Nominal heat input heating maximum (Hs) | 24.4 kW |
| Nominal heat input heating minimum (Hs) | 2.8 kW |
| Nominal heat input domestic hot water maximum (Hi) | 26.0 kW |
| Nominal heat input domestic hot water minimum (Hi) | 2.5 kW |
| Nominal heat input domestic hot water maximum (Hs) | 28.9 kW |
| Nominal heat input domestic hot water minimum (Hs) | 2.8 kW |
| Useful heating output maximum (80°C-60°C) | 21.5 kW |
| Useful heating output minimum (80°C-60°C) | 2.3 kW |
| Useful heating output maximum (50°C-30°C) | 23.6 kW |
| Useful heating output minimum (50°C-30°C) | 2.6 kW |
| Useful domestic hot water output maximum | 24.9 kW |
| Useful domestic hot water output minimum | 2.4 kW |
| Flue gas combustion efficiency | 97.4% |
| Efficiency at nominal heat input (60/80°C) Hi | 97.7% |
| Efficiency at nominal heat input (60/80°C) Hs | 87.9% |
| Efficiency at nominal heat input (30/50°C) Hi | 106.7% |
| Efficiency at nominal heat input (30/50°C) Hs | 96.1% |
| Efficiency at 30% of Qn with 30°C return Hi | 109.7% |
| Efficiency at 30% of Qn with 30°C return Hs | 98.8% |
| Efficiency at minimum (60/80°C) Hi | 93.5% |
| Efficiency at minimum (60/80°C) Hs | 84.2% |
| Efficiency stars (dir. 92/42/EEC) | **** |
| Emissions and performance | |
| NOx class | 6 |
| Flue gas temperature (G20) (80°C-60°C) | 64 °C |
| CO2 content (G20) (80°C-60°C) | 8.8% |
| CO content (0% O2) (80°C-60°C) | 81.0 ppm |
| O2 content (G20) (80°C-60°C) | 4.3% |
| Maximum flue gas flow (G20) (80°C-60°C) | 2.4 kg/h |
| Excess air (80°C-60°C) | 26% |
| Condensate pH | 3.2 |
| Maximum condensate quantity | 26 l/h |
| Heating circuit | |
| Expansion vessel pre-charge pressure | 1 bar |
| Maximum heating pressure | 3 bar |
| Expansion vessel capacity | 8 l |
| Heating temperature min/max (high temperature range) | 35 / 82 °C |
| Heating temperature min/max (low temperature range) | 20 / 45 °C |
| Domestic hot water circuit | |
| Domestic hot water temperature min/max | 40 / 65 °C |
| Specific domestic hot water flow rate (10 min, ΔT 30°C) | 13.2 l/min |
| Instantaneous hot water quantity (ΔT 25°C) | 15.4 l/min |
| Instantaneous hot water quantity (ΔT 35°C) | 11.0 l/min |
| Domestic hot water comfort stars (EN 13203) | *** |
| Minimum hot water draw-off | 2 l/min |
| Maximum domestic water pressure | 7.0 bar |
| Minimum domestic water pressure | 0.3 bar |
| Domestic hot water storage capacity | 40 l |
| Integrated domestic hot water expansion vessel | 2 l |
| Electrical characteristics | |
| Supply voltage/frequency | 230 V / 50 Hz |
| Total electrical power absorbed | 84.7 W |
| Circulator energy efficiency index (EEI) | ≤ 0.23 |
| Electrical system protection rating | IP X5D |
| Dimensions and weight | |
| Dimensions (height x width x depth) | 900 x 600 x 460 mm |
| Weight | 42.5 kg |
| Functions and equipment | |
| Functions | optimised internal silencer, 1:10 modulation ratio, SRA function, preparation for Chaffolink connectivity |
| Flue outlets | 80, 60, 50 mm |
| Gas | natural gas, LPG and propane air, no kit needed; conversion by selecting the gas type from the technical menu |
| Gas conversion kit | included as standard |