Skip to content

Description

The Beretta Mynute X 35C condensing boiler (Code 20163566) is a natural gas condensing boiler for heating and domestic hot water, with a nominal heat output of 29.19 kW at 80/60 °C and energy class A for both heating and hot water. The domestic hot water load profile is XL and the NOx class is 6.

White wall-mounted condensing boiler with central display and buttons, with text on the screen above the Beretta logo

AISI 304 L stainless steel heat exchanger with front access

The primary heat exchanger of the Mynute X 35C is made of AISI 304 L stainless steel, with a smooth, large cross-section tube for efficiency and cleanliness over time. The steel resists the corrosive action of acidic condensate and reduces the internal formation of oxides and other electrochemical phenomena typical of older systems. The wound single-spiral geometry (hydraulic circuit in series) offers a constant flow through all sections and limits the risk of clogging. The front access makes maintenance and cleaning of the combustion chamber easier.

Section of a condensing boiler with flame heat exchanger and circulation pump

Modulation up to 1:8 with low-consumption circulator

The boiler has high modulation up to 1:8. The low-consumption modulating circulator has EEI≤0.20 and is rated for a head of 6 m. Temperature control is standard, with an external sensor available as an option.

External installation with electric resistance kit or recessed installation

The Mynute X 35C is suitable for outdoor installation, with an optional electric resistance kit, and its electrical protection rating is IPX5D. Recessed installation is provided for the Mynute X 25 with an optional kit. A mounting template is supplied as standard.

PP flue with backdraught damper and C10 approval

The Mynute X 35C can be connected to chimneys using the dedicated PP flue fittings in PP Ø80, Ø60 and Ø50. It comes with a backdraught damper as standard and is approved C10 for use in pressurised shared flues.

NOx emissions of 25 mg/kWh in class 6

The Mynute X 35C's nitrogen oxide emissions are 25 mg/kWh, in class 6 according to UNI EN 15502.

Control with CONNECT IBRIDI, REC-10H IBRIDO and BeSMART

The Mynute X 35C is compatible with CONNECT IBRIDI, for managing up to two system zones, and with REC-10H IBRIDO, for managing hybrid systems. With BeSMART, Beretta's WiFi comfort control, the Mynute X 35C can be operated from smartphones and tablets via app, with all BeSMART functions, including the most advanced ones.

Wall-mounted boiler installed in a white kitchen cabinet

Panel with backlit LCD display and green light bar

The control panel has a backlit LCD display that communicates with icons and scrolling text, including in multiple languages. Seven screen-printed keys give access to the boiler and system settings and parameters. The green light bar is an LED strip that signals operating status and is reflected on the casing even when the door is closed.

White control panel with LCD display, side +/- buttons and three keys at the bottom (reset, menu)

Eight captioned icons listing the features of a boiler: digital interface, steel heat exchanger

Technical sheet

  • Model and codes
  • Model: Beretta Mynute X 35C
  • Code: 20163566
  • Category: II2H3P
  • Flue kits available: coaxial, split
  • Power and performance
  • Reduced heat input: 4.90 kW
  • Nominal heat input: 30.00 kW
  • Nominal heat output (80°/60°): 29.19 kW
  • Nominal heat output (50°/30°): 32.25 kW
  • Minimum heating pressure: 0.25 bar
  • Maximum heating pressure: 3 bar
  • Diaphragm expansion vessel: 9 l
  • Maximum heating temperature: 90°C
  • Nominal domestic hot water heat input: 34.60 kW
  • Nominal domestic hot water heat output: 36.33 kW
  • Hot water at Δt 25 °C: 19.8 l/min
  • Hot water at Δt 30 °C: 16.5 l/min
  • Hot water at Δt 35 °C: 14.2 l/min
  • Minimum domestic hot water pressure: 0.15 bar
  • Maximum domestic hot water pressure: 8 bar
  • Hot water temperature selection range: 37-60 °C
  • Energy efficiency
  • Heating energy class: A
  • Domestic hot water energy class: A
  • Domestic hot water load profile: XL
  • Modulating circulator EEI: ≤0.20
  • Features and emissions
  • Electrical power heating: 68 W
  • Electrical power domestic hot water: 79 W
  • Degree of protection: IPX5D
  • Nitrogen oxide emissions: 25 mg/kWh
  • NOx class: 6 (UNI EN 15502)
  • Dimensions and weight
  • Dimensions: 740 x 420 x 350 mm
  • Weight: 37 kg
  • Installation and connections
  • Installation: external with optional electric resistance kit, or recessed for Mynute X 25 with optional kit
  • Template: supplied as standard
  • Flues: PP Ø80, Ø60, Ø50
  • Backdraught damper: standard
  • Approval: C10 for pressurised shared flues
  • Mynute X 25: compatible with air-propane gas since November 2019, with optional kit
  • Gas: natural gas; LPG requires the conversion kit from authorised Beretta Technical Service Centres
  • Control and functions
  • Compatibility: CONNECT IBRIDI (up to two system zones), REC-10H IBRIDO, BeSMART
  • Temperature control: standard, external sensor optional
  • Functions: management of up to 2 high and/or low temperature hydraulic circuits with specific accessories, preheating to reduce domestic hot water waiting times, clock function with weekly programming on the display, connection to domestic hot water cylinder (R models)

Frequently asked questions

Can the Beretta Mynute X 35C be connected to shared chimney flues?
Yes, the Mynute X 35C is approved C10 for use in pressurised shared flues and comes with a backdraught damper as standard.
Can the Beretta Mynute X 35C be installed outdoors?
Yes, the Mynute X 35C is suitable for outdoor installation with the optional electric resistance kit, and has an electrical protection rating of IPX5D.
Which controls can operate the Beretta Mynute X 35C remotely?
The Mynute X 35C is compatible with BeSMART, Beretta's WiFi comfort control operated by app on smartphones and tablets, with CONNECT IBRIDI for up to two system zones and REC-10H IBRIDO for hybrid systems.
How many hydraulic circuits can the Beretta Mynute X 35C manage?
The Mynute X 35C manages up to 2 high and/or low temperature hydraulic circuits, using specific accessories.
How do you switch the Beretta Mynute X 35C from natural gas to LPG?
LPG conversion requires the conversion kit, to be installed by authorised Beretta Technical Service Centres.
What NOx emissions does the Beretta Mynute X 35C have?
The Mynute X 35C has nitrogen oxide emissions of 25 mg/kWh, in class 6 according to UNI EN 15502.