Skip to content

Description

The Beretta Mynute Evo X 30 C is a wall-mounted condensing boiler running on natural gas for heating and domestic hot water, Code 20205313. It has a 29.25 kW nominal heat output, class A for both heating and domestic hot water, an XL domestic hot water load profile and 1:10 modulation. It is the most recent evolution of the Mynute family, with a stainless steel heat exchanger and a flue kit available in coaxial or split version.

White wall-mounted condensing boiler with a central digital control panel, on a green background with a leaf

1:10 modulation and new stainless steel heat exchanger

The Mynute Evo X range has 1:10 modulation on all models. The Beretta Mynute Evo X 30 C features a new stainless steel heat exchanger with an updated adaptive combustion system. The aesthetic lines have been updated and suit both replacements and new builds.

ACC combustion control with no initial calibration

The ACC (Active Combustion Control) system adapts automatically to the fuel, natural gas or LPG, without specific codes or accessory conversion kits. It eliminates initial calibration and adapts to different gas configurations, pipe lengths and altitudes within design limits. It runs self-diagnostics and keeps emissions below regulatory limits.

High-performance ACS plate heat exchanger

The domestic hot water heat exchanger is developed and manufactured in-house by Beretta. It ensures comfort, fast reaching of the set point temperature and temperature stability during draw-off.

Internal section of a wall-mounted boiler with the heat exchanger highlighted in green

2.8" touchpad panel with HMI display

The control panel has seven touch points to access all the boiler and system settings and parameters. Each touch triggers a buzzer that confirms the operation. The 2.8" HMI display communicates with the user and installer through icons.

Boiler control panel with central display

Quiet operation: 45 dB(A) on the 30 C model

The new materials make the boiler quiet, which is useful if it is installed inside the home. The noise level is 45 dB(A) for the 30 C model and reaches 48 dB(A) for the 20R model.

Designed for blends of natural gas and hydrogen up to 20%

The Mynute Evo X is designed to run on blends of natural gas and hydrogen up to 20%, helping to reduce the environmental impact and emissions of condensing boilers in the coming years.

Technical sheet

  • Model and codes
  • Model: Beretta Mynute Evo X 30 C Condensing Boiler Natural Gas Low NOx Complete with Flue Kit
  • Code: 20205313
  • Flue kit: coaxial or split
  • Energy efficiency
  • Fuel: natural gas; LPG with conversion kit to be requested from authorised Beretta Technical Service Centres
  • Heating energy class: A
  • Domestic hot water energy class: A
  • Domestic hot water load profile: XL
  • Power and performance
  • Nominal heat input: 29.00 kW
  • Nominal heat output: 29.25 kW
  • Hot water at Δt 25 °C: 17.3 l/min
  • Hot water at Δt 30 °C: 14.9 l/min
  • Hot water at Δt 35 °C: 12.2 l/min
  • Minimum pressure: 0.15 bar
  • Maximum pressure: 8 bar
  • Temperature selection range: 37-60 °C
  • Features
  • Electrical power in heating: 62 W
  • Electrical power in domestic hot water: 82 W
  • Degree of protection: IPX5D
  • Nitrogen oxide emissions: 25 mg/kWh
  • NOx class: 6
  • Dimensions and weight
  • Dimensions (H x W x D): 740 x 420 x 275 mm
  • Weight: 28 kg

Frequently asked questions

What material is the heat exchanger of the Beretta Mynute Evo X 30 C made of?
The Beretta Mynute Evo X 30 C has a new stainless steel heat exchanger, with an updated adaptive combustion system.
How noisy is the Beretta Mynute Evo X 30 C?
The noise level of the Beretta Mynute Evo X 30 C is 45 dB(A).
What modulation does the Beretta Mynute Evo X 30 C have?
The Beretta Mynute Evo X 30 C has a wide 1:10 modulation, featured on all models in the Mynute Evo X range.
What does the ACC system of the Beretta Mynute Evo X 30 C do?
The ACC (Active Combustion Control) system of the Beretta Mynute Evo X 30 C adjusts combustion automatically and eliminates initial calibration.
How much hot water does the Beretta Mynute Evo X 30 C produce?
The Beretta Mynute Evo X 30 C delivers 17.3 l/min at Δt 25 °C, 14.9 l/min at Δt 30 °C and 12.2 l/min at Δt 35 °C.
Is the Beretta Mynute Evo X 30 C ready for hydrogen?
Yes, the Beretta Mynute Evo X 30 C is designed to run on blends of natural gas and hydrogen of up to 20%.