Riello
Air Conditioner Riello Inverter AARIA START N 18000 BTU R-32 AMW 50 ST N Wi-Fi Optional - Code 20211072
- 18000 BTU
- A++ cooling
- A+ heating
- Refrigerant R-32
- 5 kW cooling

What size do I need?
This 18000 BTU model suits a room of about 50 m².
Approximate, based on a 2.7 m ceiling and average insulation.
Couldn't load pickup availability
Shipping and delivery
Shipping and delivery
Timing. With online payment, your order leaves with express courier and arrives within 1-2 working days. In remote areas and on islands, a few extra days may be needed: the estimated delivery date for your postcode is shown under “When it arrives”.
Costs. For orders under €80, shipping costs €8. Delivery to your floor is available for an additional charge.
Availability. Each product shows whether it is in stock, whether only a few units are left, or whether it is sold out; for sold-out products, you can leave your email and we will let you know as soon as they are back in stock.
Your order. You can track it from your account. For any questions, you will find our contact details on the Contact page; all the terms are on the Shipping page.
Support before and after purchase
Support before and after purchase
For advice on choosing a product, a technical question or an order already placed, the Buytutto customer service team is available Monday to Friday, 9:00 am to 1:00 pm and 2:00 pm to 6:00 pm.
You can message us on WhatsApp using the button on this page, or use the contact details on the Contact page. For a product you have already received, open a request from the Support page.
Description
The Riello AARIA START N AMW 50 ST N is a wall-mounted monosplit Inverter air conditioner for small and medium-sized residential spaces. It cools with 18000 BTU and 5.00 kW in cooling mode, heats with 5.20 kW, and is energy class A++ for cooling. It uses R-32 refrigerant, which has a low environmental impact.

Inverter technology for a constant temperature
The Inverter technology adjusts the output to the actual air conditioning needs, keeping the indoor temperature constant and reducing energy consumption.
Energy efficiency: SEER 6.10 and SCOP 4.00
In cooling mode the Riello AARIA START N reaches a SEER of 6.10 (6.80 in the 24000 BTU model) with class A++. In heating, for an average climate profile, it has a SCOP of 4.00 in class A+.
Quiet operation down to 20 dB(A)
The indoor wall unit fan has 4 speeds selectable with the remote control and reaches 20 dB(A) at super-minimum speed. The outdoor unit has a high-efficiency rotary compressor with sound-absorbing insulation.
Functions and control
The supplied infrared remote control handles all functions. The Riello AARIA START N has SMART mode for automatic operation, SLEEP function for night-time comfort, QUIET function for ultra-quiet operation and AUTORESTART function in case of power interruption. The outdoor unit comes with connection covers.
Optional Wi-Fi with the RiCLOUD AC app
The Riello AARIA START N can be fitted with an optional Wi-Fi kit for remote control via the dedicated RiCLOUD AC app. The Wi-Fi version is available as a variant.
Frequently asked questions
What is the capacity of the Riello AARIA START N 18000 BTU?
Which refrigerant gas does the Riello AARIA START N use?
How quiet is the Riello AARIA START N?
What does Inverter technology mean in the Riello AARIA START N?
Does the Riello AARIA START N have Wi-Fi?
What functions does the Riello AARIA START N have?
Technical specifications
| Indoor unit catalogue code | AMW 50 ST N |
| Outdoor unit catalogue code | AARIA START 50 N |
| Technology | INVERTER ErP |
| BTU/h capacity | 18000 |
| Cooling performance | |
| Nominal airflow cooling capacity (9000 BTU) | 2.60 kW |
| Nominal airflow cooling capacity (12000 BTU) | 3.20 kW |
| Nominal airflow cooling capacity (18000 BTU) | 5.00 kW |
| Nominal airflow cooling capacity (24000 BTU) | 6.80 kW |
| Power input at nominal airflow (9000 BTU) | 0.80 kW |
| Power input at nominal airflow (12000 BTU) | 0.99 kW |
| Power input at nominal airflow (18000 BTU) | 1.55 kW |
| Power input at nominal airflow (24000 BTU) | 2.11 kW |
| EER (9000 BTU) | 3.23 kW/kW |
| EER (12000 BTU) | 3.23 kW/kW |
| EER (18000 BTU) | 3.41 kW/kW |
| EER (24000 BTU) | 3.23 kW/kW |
| Min.-max. airflow capacity (9000 BTU) | 0.80-3.00 kW |
| Min.-max. airflow capacity (12000 BTU) | 0.80-3.60 kW |
| Min.-max. airflow capacity (18000 BTU) | 1.30-5.80 kW |
| Min.-max. airflow capacity (24000 BTU) | 2.20-8.50 kW |
| Min.-max. power input at airflow (9000 BTU) | 0.30-1.20 kW |
| Min.-max. power input at airflow (12000 BTU) | 0.30-1.60 kW |
| Min.-max. power input at airflow (18000 BTU) | 0.40-2.00 kW |
| Min.-max. power input at airflow (24000 BTU) | 0.70-2.90 kW |
| Cooling energy data | |
| SEER (9000, 12000, 18000 BTU) | 6.10 kW/kW |
| SEER (24000 BTU) | 6.80 kW/kW |
| Cooling energy class (9000, 12000, 18000, 24000 BTU) | A++ |
| Annual cooling energy consumption (9000 BTU) | 149 kWh/a |
| Annual cooling energy consumption (12000 BTU) | 184 kWh/a |
| Annual cooling energy consumption (18000 BTU) | 287 kWh/a |
| Annual cooling energy consumption (24000 BTU) | 350 kWh/a |
| Heating performance | |
| Nominal airflow heating capacity (9000 BTU) | 2.80 kW |
| Nominal airflow heating capacity (12000 BTU) | 3.40 kW |
| Nominal airflow heating capacity (18000 BTU) | 5.20 kW |
| Nominal airflow heating capacity (24000 BTU) | 6.80 kW |
| Power input at nominal airflow in heating (9000 BTU) | 0.75 kW |
| Power input at nominal airflow in heating (12000 BTU) | 0.92 kW |
| Power input at nominal airflow in heating (18000 BTU) | 1.40 kW |
| Power input at nominal airflow in heating (24000 BTU) | 1.83 kW |
| COP (9000, 12000, 18000, 24000 BTU) | 3.71 kW/kW |
| Min.-max. airflow heating capacity (9000 BTU) | 0.80-3.20 kW |
| Min.-max. airflow heating capacity (12000 BTU) | 0.80-4.20 kW |
| Min.-max. airflow heating capacity (18000 BTU) | 1.40-6.00 kW |
| Min.-max. airflow heating capacity (24000 BTU) | 2.40-9.50 kW |
| Min.-max. power input at airflow in heating (9000 BTU) | 0.30-1.40 kW |
| Min.-max. power input at airflow in heating (12000 BTU) | 0.30-1.60 kW |
| Min.-max. power input at airflow in heating (18000 BTU) | 0.52-2.50 kW |
| Min.-max. power input at airflow in heating (24000 BTU) | 0.60-2.90 kW |
| Energy data for average climate profile | |
| Pdesign at -10 °C (9000 BTU) | 2.40 kW |
| Pdesign at -10 °C (12000 BTU) | 2.80 kW |
| Pdesign at -10 °C (18000 BTU) | 4.60 kW |
| Pdesign at -10 °C (24000 BTU) | 5.60 kW |
| SCOP (9000, 12000, 18000, 24000 BTU) | 4.00 kW/kW |
| Energy class for average climate profile (9000, 12000, 18000, 24000 BTU) | A+ |
| Annual energy consumption for average climate profile (9000 BTU) | 840 kWh/a |
| Annual energy consumption for average climate profile (12000 BTU) | 980 kWh/a |
| Annual energy consumption for average climate profile (18000 BTU) | 1610 kWh/a |
| Annual energy consumption for average climate profile (24000 BTU) | 1960 kWh/a |
| Energy data for warm climate profile | |
| Pdesign at +2 °C (9000 BTU) | 2.00 kW |
| Pdesign at +2 °C (12000 BTU) | 2.70 kW |
| Pdesign at +2 °C (18000 BTU) | 4.10 kW |
| Pdesign at +2 °C (24000 BTU) | 5.60 kW |
| SCOP (9000, 12000, 18000, 24000 BTU) | 5.10 kW/kW |
| Energy class for warm climate profile (9000, 12000, 18000, 24000 BTU) | A+++ |
| Annual energy consumption for warm climate profile (9000 BTU) | 549 kWh/a |
| Annual energy consumption for warm climate profile (12000 BTU) | 741 kWh/a |
| Annual energy consumption for warm climate profile (18000 BTU) | 1125 kWh/a |
| Annual energy consumption for warm climate profile (24000 BTU) | 1538 kWh/a |
| Cooling operating limits | |
| Outdoor air temperature min.-max. (DB) | -10/43 °C |
| Indoor air temperature min.-max. (WB) | 21/35 °C |
| Heating operating limits | |
| Outdoor air temperature min./max. (DB) | 10/27 °C |
| Indoor air temperature min./max. (WB) | -15/24 °C |
| Electrical specifications | |
| Power supply (V/Ph/Hz) | 230/1/50 |
| Connections | |
| Liquid connection | Ø 6.35 mm (9000, 12000, 18000, 24000 BTU) |
| Gas connection (9000, 12000) | Ø 9.52 mm |
| Gas connection (18000, 24000) | Ø 12.70 mm |
| Charging connection | Ø 12.70 mm (9000, 12000, 18000, 24000 BTU) |
| Piping | |
| Maximum height (9000, 12000 BTU) | 10 m |
| Maximum height (18000, 24000 BTU) | 15 m |
| Maximum length (9000 BTU) | 15 m |
| Maximum length (12000 BTU) | 20 m |
| Maximum length (18000, 24000 BTU) | 25 m |
| Maximum length with factory charge (9000, 12000 BTU) | 5 m |
| Maximum length with factory charge (18000, 24000 BTU) | 7 m |
| Additional refrigerant charge (9000, 12000, 18000, 24000 BTU) | 20 g/m |
| Refrigerant | R-32 |
| Functions and equipment | |
| Functions | SMART mode, SLEEP function, QUIET function, AUTORESTART function |
| Supplied with | infrared remote control, outdoor unit with connection covers |
| Wi-Fi | optional, kit to be fitted |