LG
Air Conditioner LG Dual Split Ducted 9000+12000 BTU R-32 With MU2R15 U13
- 9000 + 12000 BTU
- A+++ cooling
- A+ heating
- Refrigerant R-32
- 4,1 kW cooling

What size do I need?
Each indoor unit heats and cools its own room. Move the sliders to match your rooms:
- 9000 BTU unit: a room of about 25 m²
- 12000 BTU unit: a room of about 35 m²
Approximate, based on a 2.7 m ceiling and average insulation.
Couldn't load pickup availability
Shipping and delivery
Shipping and delivery
Timing. With online payment, your order leaves with express courier and arrives within 1-2 working days. In remote areas and on islands, a few extra days may be needed: the estimated delivery date for your postcode is shown under “When it arrives”.
Costs. For orders under €80, shipping costs €8. Delivery to your floor is available for an additional charge.
Availability. Each product shows whether it is in stock, whether only a few units are left, or whether it is sold out; for sold-out products, you can leave your email and we will let you know as soon as they are back in stock.
Your order. You can track it from your account. For any questions, you will find our contact details on the Contact page; all the terms are on the Shipping page.
Support before and after purchase
Support before and after purchase
For advice on choosing a product, a technical question or an order already placed, the Buytutto customer service team is available Monday to Friday, 9:00 am to 1:00 pm and 2:00 pm to 6:00 pm.
You can message us on WhatsApp using the button on this page, or use the contact details on the Contact page. For a product you have already received, open a request from the Support page.
Description
The LG MU2R15 U13 ducted dual split air conditioner is a system with one outdoor unit powering two ducted indoor units: the CL09F.N50 at 9000 BTU and the CL12F.N50 at 12000 BTU, with R-32 gas. It has a SEER of 8.5 and SCOP of 4.2, class A+++ for cooling and class A+ for heating, with 4.1 kW cooling and 4.7 kW heating. The wired controller is included.
Adjustable static pressure from the wired controller
With the linear static pressure adjustment (E.S.P.), the fan speed of the indoor unit is changed with a simple procedure from the wired controller. This lets the unit adapt to ducts of different lengths.
Condensate pump that lifts up to 700 mm

The condensate pump drains the water automatically when gravity drainage is not possible. It can lift the condensate up to 700 mm.
Dual thermistor control
With the wired controller, the room temperature can be detected in three ways: by the sensor in the wired controller, by the sensor on the unit, or by both, using the lower of the two values as the reference. The combined control optimises the indoor air temperature.
Multiple rooms with a single indoor unit

With spiral ducts (concealed or flexible) and a plenum box, the same indoor unit can cool or heat several rooms at the same time. The zone control manages more than 4 zones with an external thermostat, keeps the air volume constant in each zone and automatically adjusts fan speed and on/off operation.
Reduced noise, higher static pressure
In low-static-pressure ducted units the noise level has been considerably reduced, while the usable static pressure has increased.
Air intake from the bottom or rear

In low-static-pressure ducted units, the air intake direction can be chosen between bottom and rear. This simplifies installation and makes it possible even in tight spaces.
Maintenance without opening the whole panel
The panel is split into one panel for the heat exchanger and one for the motor and fan, so you do not need to open the whole panel for maintenance or repair. The filter is easy to remove and refit, even in limited spaces.
Frequently asked questions
What does the LG MU2R15 U13 ducted dual split kit contain?
How efficient is the LG MU2R15 U13 dual split?
What outdoor temperatures can the LG MU2R15 U13 operate in?
Can the LG ducted dual split serve several rooms?
How is condensate drained if gravity drainage is not possible?
How is the fan static pressure adjusted on the LG ducted dual split?
Technical specifications
| Model and codes | |
| 9000 BTU indoor unit | CL09F.N50 |
| 12000 BTU indoor unit | CL12F.N50 |
| Outdoor unit | MU2R15 U13 |
| Controller | wired, included |
| Refrigerant gas | R-32 |
| Energy efficiency | |
| SEER | 8.5 |
| SCOP | 4.2 |
| Cooling energy efficiency class | A+++ |
| Heating energy efficiency class | A+ |
| Power | |
| Cooling capacity (kW) | 4.1 |
| Heating capacity (kW) | 4.7 |
| Cooling, min~max (°C) | -10~48 |
| Heating, min~max (°C) | -18~18 |
| Dimensions and weight | |
| 9000 BTU indoor unit, LxHxD (mm) | 900 x 190 x 460 |
| 9000 BTU indoor unit, weight | 18 kg |
| 12000 BTU indoor unit, LxHxD (mm) | 900 x 190 x 460 |
| 12000 BTU indoor unit, weight | 18 kg |
| Outdoor unit, LxHxD (mm) | 770 x 545 x 288 |
| Outdoor unit, weight | 37 kg |
| Functions and equipment | |
| Functions | linear E.S.P. adjustment from the wired controller; dual thermistor; condensate pump with lift up to 700 mm; multi-zone control with more than 4 zones; air intake from bottom or rear |