{"product_id":"pompa-di-calore-idronica-beretta-modello-hydro-unit-m-006-monofase-r-32-aria-acqua-comando-escluso","title":"Hydronic Heat Pump Beretta Model HYDRO UNIT M 006 Single-Phase R-32 Air-Water Controller Not Included","description":"\u003cp\u003e\u003cstrong\u003eBeretta HYDRO UNIT M 006\u003c\/strong\u003e is a single-phase air-to-water hydronic heat pump with R-32 refrigerant, for heating, cooling and domestic hot water with storage tanks or solar kits. In heating mode it delivers \u003cstrong\u003e6.35 kW of useful output with water at 35 °C\u003c\/strong\u003e and a \u003cstrong\u003eCOP of 4.95\u003c\/strong\u003e, with \u003cstrong\u003eenergy class A+++\u003c\/strong\u003e up to 35 °C. In cooling mode, useful output reaches \u003cstrong\u003e7.00 kW with water at 7 °C\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0902\/2177\/3121\/files\/beretta-hydro-unit-m_1c825974-2af7-4e94-a9e1-6513ac71f110.jpg?v=1747425419\" alt=\"Two white outdoor units of an air-to-water heat pump\" width=\"930\" height=\"270\"\u003e\u003c\/p\u003e\u003ch2\u003eSystem combinations\u003c\/h2\u003e\u003cp\u003eThe heat pump can be combined with fan coil units, underfloor heating, high-efficiency low-temperature radiators, domestic hot water tanks and solar kits, all supplied on site.\u003c\/p\u003e\u003ch2\u003eHYDRO UNIT M series: ten models from 4 to 16 kW\u003c\/h2\u003e\u003cp\u003eThe HYDRO UNIT M series includes ten models with outputs from 4 kW to 16 kW, with a fast response to demand and reduced energy consumption. Class A+++ applies up to 35 °C and A++ up to 55 °C.\u003c\/p\u003e\u003ch2\u003eTwin rotary compressor and inverter board\u003c\/h2\u003e\u003cp\u003eThe twin rotary compressor is a DC double rotary compressor. Together with the fan motor and the pump, it works with the Inverter System and precisely controls motor speed, delivering the power needed for the actual load and saving energy. The inverter control board maximises output under critical load conditions and ensures stability and efficiency at partial loads.\u003c\/p\u003e\u003ch2\u003eElectronic expansion valve and operating parameters board\u003c\/h2\u003e\u003cp\u003eThe electronic expansion valve optimises the flow of refrigerant in every situation. The operating parameters control board constantly monitors ambient and water temperature to activate the various components and meet demand.\u003c\/p\u003e\u003ch2\u003eSpecial blade fan and aluminium coil\u003c\/h2\u003e\u003cp\u003eThe fan has a specially designed blade that optimises the airflow surface, improves efficiency and reduces fan noise. The heat exchange coil has an extended surface and aluminium fins.\u003c\/p\u003e\u003ch2\u003eAISI 316 stainless steel plate heat exchanger\u003c\/h2\u003e\u003cp\u003eThe AISI 316 stainless steel plate heat exchanger is protected by closed-cell anti-condensation insulation and offers high heat exchange efficiency.\u003c\/p\u003e\u003csection data-ai-faq=\"1\" itemscope itemtype=\"https:\/\/schema.org\/FAQPage\"\u003e\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\u003csummary itemprop=\"name\"\u003eWhat systems is the Beretta HYDRO UNIT M 006 used for?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003eThe Beretta HYDRO UNIT M 006 is used for heating, cooling and domestic hot water with storage tanks or solar kits. It combines with fan coil units, underfloor heating, high-efficiency low-temperature radiators and solar kits, all supplied on site.\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\u003csummary itemprop=\"name\"\u003eDoes the Beretta HYDRO UNIT M 006 need to be installed outdoors?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003eYes, the HYDRO UNIT M 006 is designed for outdoor installation. Its anti-freeze function, which can be programmed by the customer, activates automatically when the water temperature drops below a preset value.\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\u003csummary itemprop=\"name\"\u003eWhich refrigerant gas does the HYDRO UNIT M 006 use?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003eThe HYDRO UNIT M 006 uses R-32 gas, which has a lower Global Warming Potential than traditional gases, and is installed in a sealed circuit for fluorinated gases.\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\u003csummary itemprop=\"name\"\u003eHow quiet is the Beretta HYDRO UNIT M 006?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003eThe low noise level of the HYDRO UNIT M 006 comes from its construction features and can be reduced further with the Quiet Mode, which can be programmed by the customer. The special blade fan also helps reduce fan noise.\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\u003csummary itemprop=\"name\"\u003eWhat is the backup heater of the HYDRO UNIT M 006 for?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003eThe backup heater, available as an accessory, increases heating capacity when outdoor temperatures are cold. It also acts as a backup in case of an operating fault and protects the external water pipes from frost during winter.\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\u003csummary itemprop=\"name\"\u003eWhat is the difference between a hydronic kit and a hydronic module?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003eThe hydronic kit is supplied with the monoblock and contains the essential components for installation. The hydronic module of the HYDRO UNIT M 006 includes a low-consumption circulator pump, an 8-litre expansion vessel, an automatic air vent and a safety valve.\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003c\/section\u003e\u003ch2\u003eHydronic kit and hydronic module\u003c\/h2\u003e\u003cp\u003eThe hydronic kit is supplied with the monoblock and contains all the essential components for installation. The hydronic module includes a low-consumption circulator pump, an 8-litre expansion vessel, an automatic air vent and a safety valve. The maximum operating pressure of the hydronic circuit is 3 bar.\u003c\/p\u003e\u003ch2\u003eOutdoor installation with anti-freeze function\u003c\/h2\u003e\u003cp\u003eThe HYDRO UNIT M 006 is designed for outdoor installation. The anti-freeze function, which can be programmed by the customer, activates automatically when the water temperature in the system drops below a preset value, protecting the entire hydraulic circuit.\u003c\/p\u003e\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0902\/2177\/3121\/files\/hydro_unit_1_7cecf2bb-93f1-464c-9d7f-1a806535187a.png?v=1747425426\" alt=\"White outdoor unit of a heat pump installed on a wooden terrace, next to a large glass window\" width=\"790\" height=\"564\"\u003e\u003c\/p\u003e\u003ch2\u003eQuiet Mode\u003c\/h2\u003e\u003cp\u003eThe low noise level comes from its construction features and can be further reduced with the Quiet Mode, which can be programmed by the customer.\u003c\/p\u003e\u003ch2\u003eBackup heater available as an accessory\u003c\/h2\u003e\u003cp\u003eThe backup heater, available as an accessory, increases heating capacity when outdoor temperatures are cold. It also serves as a backup in case of an operating fault and as frost protection for the external water pipes during winter.\u003c\/p\u003e\u003ch2\u003eR-32 and HP KEYMARK certification\u003c\/h2\u003e\u003cp\u003eR-32 gas has a lower Global Warming Potential than traditional gases. The sealed circuit for fluorinated gases, the reduced refrigerant charge volumes and lower CO2 emissions increase the environmental sustainability of the HYDRO UNIT M. The design meets the requirements of the voluntary European HP KEYMARK certification.\u003c\/p\u003e\u003ch2\u003eTechnical data sheet\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eModel and codes\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eModel: HYDRO UNIT M 006\u003c\/li\u003e\n\u003cli\u003eType: air-to-water hydronic heat pump, monoblock\u003c\/li\u003e\n\u003cli\u003ePower supply: single-phase\u003c\/li\u003e\n\u003cli\u003eRefrigerant: R-32\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEnergy efficiency\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eHeating energy class with water at 35 °C: A+++\u003c\/li\u003e\n\u003cli\u003eHeating energy class with water at 55 °C: A++\u003c\/li\u003e\n\u003cli\u003eHeating COP with water at 35 °C: 4.95\u003c\/li\u003e\n\u003cli\u003eHeating COP with water at 45 °C: 3.70\u003c\/li\u003e\n\u003cli\u003eHeating COP with water at 55 °C: 2.95\u003c\/li\u003e\n\u003cli\u003eCooling EER with water at 7 °C: 3.00\u003c\/li\u003e\n\u003cli\u003eCooling EER with water at 18 °C: 4.80\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003ePower and performance\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eUseful heating output with water at 35 °C: 6.35 kW\u003c\/li\u003e\n\u003cli\u003eUseful heating output with water at 45 °C: 6.30 kW\u003c\/li\u003e\n\u003cli\u003eUseful heating output with water at 55 °C: 6.00 kW\u003c\/li\u003e\n\u003cli\u003eHeating power input with water at 35 °C: 1.28 kW\u003c\/li\u003e\n\u003cli\u003eHeating power input with water at 45 °C: 1.70 kW\u003c\/li\u003e\n\u003cli\u003eHeating power input with water at 55 °C: 2.03 kW\u003c\/li\u003e\n\u003cli\u003eUseful cooling output with water at 7 °C: 7.00 kW\u003c\/li\u003e\n\u003cli\u003eUseful cooling output with water at 18 °C: 6.50 kW\u003c\/li\u003e\n\u003cli\u003eCooling power input with water at 7 °C: 2.33 kW\u003c\/li\u003e\n\u003cli\u003eCooling power input with water at 18 °C: 1.35 kW\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eMaximum operating pressure of hydronic circuit: 3 bar\u003c\/li\u003e\n\u003cli\u003eMaximum power input: 0.043 kW\u003c\/li\u003e\n\u003cli\u003eSystem expansion vessel: 8 litres\u003c\/li\u003e\n\u003cli\u003eCertification: HP KEYMARK\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDimensions and weight\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eDimensions (L x H x D): 1295x792x429 mm\u003c\/li\u003e\n\u003cli\u003eEmpty weight: 98.0 kg\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Beretta","offers":[{"title":"Default Title","offer_id":44284387590198,"sku":"HYDRO_UNIT_M006","price":2940.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0636\/9299\/6662\/files\/22995.jpg?v=1764732843","url":"https:\/\/buytutto.com\/en-eu\/products\/hydronic-heat-pump-beretta-model-hydro-unit-m-006-single-phase-r-32-air-water-controller-not-included","provider":"BuyTutto.com","version":"1.0","type":"link"}