{"product_id":"pompa-di-calore-idronica-beretta-modello-hydro-unit-m-016t-trifase-r-32-aria-acqua-comando-incluso-cod-20203678","title":"Hydronic Heat Pump Beretta Model HYDRO UNIT M 016T Three-Phase R-32 Air-to-Water Code 20203678 - Controller Included","description":"\u003cp\u003eThe \u003cstrong\u003eBeretta HYDRO UNIT M 016T\u003c\/strong\u003e heat pump is a three-phase monobloc air-to-water heat pump with R-32 gas and wired controller included (code 20203678). It is used for heating, cooling and domestic hot water with a cylinder, and is designed for outdoor installation. It delivers \u003cstrong\u003e15.90 kW of useful heating output at 35 °C\u003c\/strong\u003e, a COP of 4.50 with water at 35 °C and class A+++ at 35 °C.\u003c\/p\u003e\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0902\/2177\/3121\/files\/beretta-hydro-unit-m_1c825974-2af7-4e94-a9e1-6513ac71f110.jpg?v=1747425419\" alt=\"Two white outdoor units of an air-to-water heat pump\" width=\"930\" height=\"270\"\u003e\u003c\/p\u003e\u003ch2\u003eClass A+++ with water at 35 °C and A++ at 55 °C\u003c\/h2\u003e\u003cp\u003eThe Beretta HYDRO UNIT M 016T achieves \u003cstrong\u003eclass A+++ with water at 35 °C\u003c\/strong\u003e and class A++ with water at 55 °C. The COP for heating is 4.50 with water at 35 °C, 3.50 at 45 °C and 2.85 at 55 °C. For cooling, the EER is 3.61 with water at 7 °C and 2.50 with water at 18 °C.\u003c\/p\u003e\u003ch2\u003eUseful output up to 16.00 kW\u003c\/h2\u003e\u003cp\u003eThe useful heating output is \u003cstrong\u003e15.90 kW\u003c\/strong\u003e with water set to 35 °C and 16.00 kW with water at 45 °C and 55 °C. The HYDRO UNIT M series comprises ten models with outputs from 4 kW to 16 kW.\u003c\/p\u003e\u003ch2\u003eRefrigerant \u003cstrong\u003eR-32\u003c\/strong\u003e and lower environmental impact\u003c\/h2\u003e\u003cp\u003eThe HYDRO UNIT M 016T uses R-32 as its refrigerant, a gas with a lower global warming potential than traditional gases. The sealed circuit for fluorinated gases, the reduced charge volumes and the lower CO2 emissions increase the environmental sustainability of the model.\u003c\/p\u003e\u003ch2\u003eQuiet mode and \u003cstrong\u003efrost protection function\u003c\/strong\u003e\n\u003c\/h2\u003e\u003cp\u003eLow noise levels are ensured by the construction design and are further reduced with the Quiet mode, which can be programmed by the customer. The frost protection function, also programmable, activates automatically when the water temperature in the system drops below a preset value and protects the entire hydronic circuit of the HYDRO UNIT M 016T.\u003c\/p\u003e\u003csection data-ai-faq=\"1\" itemscope itemtype=\"https:\/\/schema.org\/FAQPage\"\u003e\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\u003csummary itemprop=\"name\"\u003eWhat refrigerant gas does the Beretta HYDRO UNIT M 016T use?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003eThe Beretta HYDRO UNIT M 016T uses R-32 as its refrigerant, a gas with a lower global warming potential than traditional gases, in a sealed circuit.\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\u003csummary itemprop=\"name\"\u003eIs the Beretta HYDRO UNIT M 016T installed outdoors?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003eYes, the HYDRO UNIT M 016T is designed for outdoor installation and includes a frost protection function that protects the entire hydronic circuit.\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\u003csummary itemprop=\"name\"\u003eWhich systems can the HYDRO UNIT M 016T be paired with?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003eThe HYDRO UNIT M 016T combines with fan coil units, underfloor heating, high-efficiency low-temperature radiators, domestic hot water cylinders and solar kits, which are field-supplied.\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\u003csummary itemprop=\"name\"\u003eIs a backup heater included with the HYDRO UNIT M 016T?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003eNo, the backup heater is available as an accessory. It increases heating capacity in cold outdoor temperatures and protects the external water pipes from frost.\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\u003csummary itemprop=\"name\"\u003eWhat does the hydronic kit of the HYDRO UNIT M 016T include?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003eThe hydronic kit supplied with the HYDRO UNIT M 016T includes a low-consumption circulator, expansion vessel, automatic air vent and safety valve.\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\u003csummary itemprop=\"name\"\u003eIs the Beretta HYDRO UNIT M 016T quiet?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003eLow noise levels are ensured by the construction design of the HYDRO UNIT M 016T and are further reduced with the Quiet mode, which can be programmed by the customer.\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003c\/section\u003e\u003ch2\u003eInverter \u003cstrong\u003etwin rotary DC\u003c\/strong\u003e compressor\n\u003c\/h2\u003e\u003cp\u003eThe twin rotary DC compressor, together with the inverter control board, precisely adjusts motor speed to the output needed for the actual load. The inverter board maximises output under critical load conditions and ensures stability at part loads. The electronic expansion valve optimises refrigerant flow in every situation.\u003c\/p\u003e\u003ch2\u003ePlate heat exchanger in \u003cstrong\u003eAISI 316 stainless steel\u003c\/strong\u003e\n\u003c\/h2\u003e\u003cp\u003eThe AISI 316 stainless steel plate heat exchanger is protected by closed-cell anti-condensation insulation and offers high heat exchange efficiency. The heat exchange coil has an extended surface with aluminium fins.\u003c\/p\u003e\u003ch2\u003eIntegrated hydronic kit and outdoor installation\u003c\/h2\u003e\u003cp\u003eThe hydronic kit supplied with the monobloc includes a low-consumption circulator, expansion vessel, automatic air vent and safety valve. The HYDRO UNIT M 016T is designed for outdoor installation, as shown in the photo below.\u003c\/p\u003e\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0902\/2177\/3121\/files\/hydro_unit_1_7cecf2bb-93f1-464c-9d7f-1a806535187a.png?v=1747425426\" alt=\"White outdoor unit of a heat pump installed on a wooden terrace, next to a large glass window\" width=\"790\" height=\"564\"\u003e\u003c\/p\u003e\u003cp\u003eIt combines with fan coil units, underfloor heating, high-efficiency low-temperature radiators, domestic hot water cylinders and solar kits, which are field-supplied.\u003c\/p\u003e\u003ch2\u003eCertification \u003cstrong\u003eHP KEYMARK\u003c\/strong\u003e\n\u003c\/h2\u003e\u003cp\u003eThe design of the HYDRO UNIT M 016T meets the requirements of the voluntary European HP KEYMARK certification.\u003c\/p\u003e\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eModel and codes\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eModel: HYDRO UNIT M 016T\u003c\/li\u003e\n\u003cli\u003eCode: 20203678\u003c\/li\u003e\n\u003cli\u003eType: air-to-water hydronic heat pump, monobloc\u003c\/li\u003e\n\u003cli\u003ePower supply: three-phase\u003c\/li\u003e\n\u003cli\u003eRefrigerant gas: R-32\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eOutput and performance\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eUseful heating output with water at 35 °C: 15.90 kW\u003c\/li\u003e\n\u003cli\u003eUseful heating output with water at 45 °C: 16.00 kW\u003c\/li\u003e\n\u003cli\u003eUseful heating output with water at 55 °C: 16.00 kW\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEnergy efficiency\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eEnergy class for heating at 35 °C: A+++\u003c\/li\u003e\n\u003cli\u003eEnergy class for heating at 55 °C: A++\u003c\/li\u003e\n\u003cli\u003eCOP heating with water at 35 °C: 4.50\u003c\/li\u003e\n\u003cli\u003eCOP heating with water at 45 °C: 3.50\u003c\/li\u003e\n\u003cli\u003eCOP heating with water at 55 °C: 2.85\u003c\/li\u003e\n\u003cli\u003eEER cooling with water at 7 °C: 3.61\u003c\/li\u003e\n\u003cli\u003eEER cooling with water at 18 °C: 2.50\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDimensions and weight\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eDimensions (W x H x D): 1385 x 945 x 526 mm\u003c\/li\u003e\n\u003cli\u003eEmpty weight: 144 kg\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eInstallation and functions\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eInstallation: outdoor\u003c\/li\u003e\n\u003cli\u003eController: wired controller included\u003c\/li\u003e\n\u003cli\u003eBackup heater: available as an accessory\u003c\/li\u003e\n\u003cli\u003eFunctions: hydronic kit with circulator, expansion vessel, automatic air vent and safety valve; frost protection function; Quiet mode; inverter control board; electronic expansion valve\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMaterials\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eHeat exchanger: AISI 316 stainless steel plate\u003c\/li\u003e\n\u003cli\u003eHeat exchange coil: aluminium fins\u003c\/li\u003e\n\u003cli\u003eCertification: design meeting HP KEYMARK requirements\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Beretta","offers":[{"title":"Default Title","offer_id":44284388048950,"sku":"HYDRO_UNIT_M016T","price":4498.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0636\/9299\/6662\/files\/30972.jpg?v=1764732913","url":"https:\/\/buytutto.com\/en-eu\/products\/hydronic-heat-pump-beretta-hydro-unit-m-016t-three-phase-r-32-air-to-water-controller-included-code-20203678","provider":"BuyTutto.com","version":"1.0","type":"link"}