Beretta
Hydronic Heat Pump Beretta Model HYDRO UNIT M 014 Single-Phase R-32 Air-to-Water Code 20203659 - Controller Included

What size do I need?
For heat pumps and fan coils the right output is worked out by the installer on your home: heat loss, system, climate zone. Send us your measurements and we will reply with a quote.
Couldn't load pickup availability
Shipping and delivery
Shipping and delivery
Timing. With online payment, your order leaves with express courier and arrives within 1-2 working days. In remote areas and on islands, a few extra days may be needed: the estimated delivery date for your postcode is shown under “When it arrives”.
Costs. For orders under €80, shipping costs €8. Delivery to your floor is available for an additional charge.
Availability. Each product shows whether it is in stock, whether only a few units are left, or whether it is sold out; for sold-out products, you can leave your email and we will let you know as soon as they are back in stock.
Your order. You can track it from your account. For any questions, you will find our contact details on the Contact page; all the terms are on the Shipping page.
Support before and after purchase
Support before and after purchase
For advice on choosing a product, a technical question or an order already placed, the Buytutto customer service team is available Monday to Friday, 9:00 am to 1:00 pm and 2:00 pm to 6:00 pm.
You can message us on WhatsApp using the button on this page, or use the contact details on the Contact page. For a product you have already received, open a request from the Support page.
Description
The Beretta HYDRO UNIT M 014 (Code 20203659) is a single-phase air-to-water hydronic heat pump with R-32 gas, with wired controller included, designed for heating, cooling and domestic hot water. With water set to 35 °C, it delivers 14.50 kW of usable heating output, with a COP of 4.60 and an A+++ class. It is part of a range of ten models from 4 kW to 16 kW.

Usable output and COP with water at 35, 45 and 55 °C
The usable heating output drops from 14.50 kW with water at 35 °C to 14.10 kW at 45 °C and 13.80 kW at 55 °C. The heating COP is 4.60 at 35 °C, 3.50 at 45 °C and 2.95 at 55 °C. In cooling mode, the EER is 3.61 with water at 7 °C and 2.50 with water at 18 °C.
Twin rotary inverter compressor that matches output to the load
The twin rotary DC compressor, together with the fan motor and the pump, precisely regulates motor speed to match the power required by the actual load and saves energy. The inverter control board maximises output under critical load conditions and ensures stability and efficiency at partial loads. As a result, the energy class is A+++ up to 35 °C and A++ up to 55 °C.
Low-noise fan and silent mode
The fan has a special blade and blade edge design that improves efficiency and reduces fan noise. The low noise level comes from the construction design and can be further reduced with the Silent Mode, programmable by the customer.
Hydronic kit included with AISI 316 steel heat exchanger
The hydronic kit supplied with the monobloc unit contains a hydronic module with a low-consumption circulator pump, expansion vessel, automatic air vent and safety valve. The AISI 316 steel plate heat exchanger is protected by closed-cell anti-condensation insulation. The heat exchange coil has an extended surface and aluminium fins.
Outdoor installation with R-32 refrigerant
The heat pump is designed for outdoor installation and includes the programmable anti-freeze function, which activates automatically when the water temperature in the system drops below a preset value. The R-32 refrigerant gas has a lower Global Warming Potential than traditional gases, with reduced charge volumes and lower CO2 emissions.

HP KEYMARK certification and compatible systems
The design meets the requirements of the voluntary European certification HP KEYMARK. The pump can be combined with fan coil units, underfloor heating, high-efficiency low-temperature radiators, domestic hot water tanks and solar kits, all supplied on site.
Wired controller included and backup heater
The wired controller is supplied with the unit. The backup heater, available as an accessory, increases heating capacity in cold outdoor temperatures, serves as a backup in the event of an operating fault, and protects the external water pipes from frost during winter.
Frequently asked questions
Which refrigerant gas does the Beretta HYDRO UNIT M 014 use?
How noisy is the Beretta HYDRO UNIT M 014?
Which systems can the HYDRO UNIT M 014 heat pump be connected to?
Is the backup heater needed with the HYDRO UNIT M 014?
What does the anti-freeze function of the HYDRO UNIT M 014 do?
Is the hydronic kit included with the Beretta HYDRO UNIT M 014?
Technical specifications
| Model and codes | |
| Brand | Beretta |
| Model | HYDRO UNIT M 014 |
| Code | 20203659 |
| Type | single-phase air-to-water hydronic heat pump |
| Refrigerant gas | R-32 |
| Output and performance | |
| Usable heating output with water at 35 °C | 14.50 kW |
| Usable heating output with water at 45 °C | 14.10 kW |
| Usable heating output with water at 55 °C | 13.80 kW |
| Heating COP with water at 35 °C | 4.60 |
| Heating COP with water at 45 °C | 3.50 |
| Heating COP with water at 55 °C | 2.95 |
| Energy efficiency | |
| Heating energy class at 35 °C | A+++ |
| Heating energy class at 55 °C | A++ |
| Cooling EER with water at 7 °C | 3.61 |
| Cooling EER with water at 18 °C | 2.50 |
| Dimensions and weight | |
| Dimensions (WxHxD) | 1385x945x526 mm |
| Empty weight | 144 kg |
| Functions and supply | |
| Wired controller | included |
| Anti-freeze function | programmable by the customer |
| Silent mode | programmable by the customer |
| Backup heater | accessory available separately |
| Certification | HP KEYMARK (design compliant) |
| Range | ten models from 4 kW to 16 kW |