{"product_id":"pompa-di-calore-idronica-beretta-modello-hydro-unit-m-014-monofase-r-32-aria-acqua-comando-incluso-cod-20203659","title":"Hydronic Heat Pump Beretta Model HYDRO UNIT M 014 Single-Phase R-32 Air-to-Water Code 20203659 - Controller Included","description":"\u003cp\u003eThe \u003cstrong\u003eBeretta HYDRO UNIT M 014\u003c\/strong\u003e (Code 20203659) is a single-phase air-to-water hydronic heat pump with R-32 gas, with wired controller included, designed for heating, cooling and domestic hot water. With water set to 35 °C, it delivers \u003cstrong\u003e14.50 kW\u003c\/strong\u003e of usable heating output, with a COP of 4.60 and an A+++ class. It is part of a range of ten models from 4 kW to 16 kW.\u003c\/p\u003e\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0902\/2177\/3121\/files\/beretta-hydro-unit-m_1c825974-2af7-4e94-a9e1-6513ac71f110.jpg?v=1747425419\" alt=\"Two white outdoor units of an air-to-water heat pump\" width=\"930\" height=\"270\"\u003e\u003c\/p\u003e\u003ch2\u003eUsable output and COP with water at 35, 45 and 55 °C\u003c\/h2\u003e\u003cp\u003eThe usable heating output drops from \u003cstrong\u003e14.50 kW\u003c\/strong\u003e with water at 35 °C to 14.10 kW at 45 °C and 13.80 kW at 55 °C. The heating COP is 4.60 at 35 °C, 3.50 at 45 °C and 2.95 at 55 °C. In cooling mode, the EER is 3.61 with water at 7 °C and 2.50 with water at 18 °C.\u003c\/p\u003e\u003ch2\u003eTwin rotary inverter compressor that matches output to the load\u003c\/h2\u003e\u003cp\u003eThe \u003cstrong\u003etwin rotary DC compressor\u003c\/strong\u003e, together with the fan motor and the pump, precisely regulates motor speed to match the power required by the actual load and saves energy. The inverter control board maximises output under critical load conditions and ensures stability and efficiency at partial loads. As a result, the energy class is A+++ up to 35 °C and A++ up to 55 °C.\u003c\/p\u003e\u003ch2\u003eLow-noise fan and silent mode\u003c\/h2\u003e\u003cp\u003eThe fan has a special blade and blade edge design that improves efficiency and reduces fan noise. The low noise level comes from the construction design and can be further reduced with the \u003cstrong\u003eSilent Mode\u003c\/strong\u003e, programmable by the customer.\u003c\/p\u003e\u003ch2\u003eHydronic kit included with AISI 316 steel heat exchanger\u003c\/h2\u003e\u003cp\u003eThe hydronic kit supplied with the monobloc unit contains a hydronic module with a low-consumption circulator pump, expansion vessel, automatic air vent and safety valve. The \u003cstrong\u003eAISI 316 steel\u003c\/strong\u003e plate heat exchanger is protected by closed-cell anti-condensation insulation. The heat exchange coil has an extended surface and aluminium fins.\u003c\/p\u003e\u003csection data-ai-faq=\"1\" itemscope itemtype=\"https:\/\/schema.org\/FAQPage\"\u003e\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\u003csummary itemprop=\"name\"\u003eWhich refrigerant gas does the Beretta HYDRO UNIT M 014 use?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003eThe Beretta HYDRO UNIT M 014 uses R-32 refrigerant gas, which has a lower Global Warming Potential than traditional gases, with reduced charge volumes.\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\u003csummary itemprop=\"name\"\u003eHow noisy is the Beretta HYDRO UNIT M 014?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003eThe Beretta HYDRO UNIT M 014 is built to have a low noise level, which can be reduced further with the programmable Silent Mode.\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\u003csummary itemprop=\"name\"\u003eWhich systems can the HYDRO UNIT M 014 heat pump be connected to?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003eThe HYDRO UNIT M 014 heat pump can be combined with fan coil units, underfloor heating, high-efficiency low-temperature radiators, domestic hot water tanks and solar kits, all supplied on site.\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\u003csummary itemprop=\"name\"\u003eIs the backup heater needed with the HYDRO UNIT M 014?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003eThe backup heater for the HYDRO UNIT M 014 is an accessory that increases heating capacity in cold outdoor temperatures and protects the external water pipes from frost in winter.\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\u003csummary itemprop=\"name\"\u003eWhat does the anti-freeze function of the HYDRO UNIT M 014 do?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003eThe anti-freeze function of the HYDRO UNIT M 014 activates automatically when the water temperature in the system drops below a preset value, protecting the entire hydraulic circuit.\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\u003csummary itemprop=\"name\"\u003eIs the hydronic kit included with the Beretta HYDRO UNIT M 014?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003eYes, the hydronic kit of the Beretta HYDRO UNIT M 014 is supplied with the monobloc unit and includes a low-consumption circulator pump, expansion vessel, automatic air vent and safety valve.\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003c\/section\u003e\u003ch2\u003eOutdoor installation with R-32 refrigerant\u003c\/h2\u003e\u003cp\u003eThe heat pump is designed for outdoor installation and includes the programmable anti-freeze function, which activates automatically when the water temperature in the system drops below a preset value. The \u003cstrong\u003eR-32\u003c\/strong\u003e refrigerant gas has a lower Global Warming Potential than traditional gases, with reduced charge volumes and lower CO2 emissions.\u003c\/p\u003e\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0902\/2177\/3121\/files\/hydro_unit_1_7cecf2bb-93f1-464c-9d7f-1a806535187a.png?v=1747425426\" alt=\"White outdoor unit of a heat pump installed on a wooden terrace, next to a large glass window\" width=\"790\" height=\"564\"\u003e\u003c\/p\u003e\u003ch2\u003eHP KEYMARK certification and compatible systems\u003c\/h2\u003e\u003cp\u003eThe design meets the requirements of the voluntary European certification \u003cstrong\u003eHP KEYMARK\u003c\/strong\u003e. The pump can be combined with fan coil units, underfloor heating, high-efficiency low-temperature radiators, domestic hot water tanks and solar kits, all supplied on site.\u003c\/p\u003e\u003ch2\u003eWired controller included and backup heater\u003c\/h2\u003e\u003cp\u003eThe wired controller is supplied with the unit. The \u003cstrong\u003ebackup heater\u003c\/strong\u003e, available as an accessory, increases heating capacity in cold outdoor temperatures, serves as a backup in the event of an operating fault, and protects the external water pipes from frost during winter.\u003c\/p\u003e\u003ch2\u003eTechnical data sheet\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eModel and codes\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eBrand: Beretta\u003c\/li\u003e\n\u003cli\u003eModel: HYDRO UNIT M 014\u003c\/li\u003e\n\u003cli\u003eCode: 20203659\u003c\/li\u003e\n\u003cli\u003eType: single-phase air-to-water hydronic heat pump\u003c\/li\u003e\n\u003cli\u003eRefrigerant gas: R-32\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eOutput and performance\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eUsable heating output with water at 35 °C: 14.50 kW\u003c\/li\u003e\n\u003cli\u003eUsable heating output with water at 45 °C: 14.10 kW\u003c\/li\u003e\n\u003cli\u003eUsable heating output with water at 55 °C: 13.80 kW\u003c\/li\u003e\n\u003cli\u003eHeating COP with water at 35 °C: 4.60\u003c\/li\u003e\n\u003cli\u003eHeating COP with water at 45 °C: 3.50\u003c\/li\u003e\n\u003cli\u003eHeating COP with water at 55 °C: 2.95\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEnergy efficiency\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eHeating energy class at 35 °C: A+++\u003c\/li\u003e\n\u003cli\u003eHeating energy class at 55 °C: A++\u003c\/li\u003e\n\u003cli\u003eCooling EER with water at 7 °C: 3.61\u003c\/li\u003e\n\u003cli\u003eCooling EER with water at 18 °C: 2.50\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDimensions and weight\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eDimensions (WxHxD): 1385x945x526 mm\u003c\/li\u003e\n\u003cli\u003eEmpty weight: 144 kg\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eFunctions and supply\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eWired controller: included\u003c\/li\u003e\n\u003cli\u003eAnti-freeze function: programmable by the customer\u003c\/li\u003e\n\u003cli\u003eSilent mode: programmable by the customer\u003c\/li\u003e\n\u003cli\u003eBackup heater: accessory available separately\u003c\/li\u003e\n\u003cli\u003eCertification: HP KEYMARK (design compliant)\u003c\/li\u003e\n\u003cli\u003eRange: ten models from 4 kW to 16 kW\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Beretta","offers":[{"title":"Default Title","offer_id":44284387917878,"sku":"HYDRO_UNIT_M014","price":3988.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0636\/9299\/6662\/files\/30963.jpg?v=1764732886","url":"https:\/\/buytutto.com\/en-eu\/products\/hydronic-heat-pump-beretta-hydro-unit-m-014-single-phase-r-32-air-to-water-controller-included-code-20203659","provider":"BuyTutto.com","version":"1.0","type":"link"}