{"product_id":"recuperatore-di-calore-fantini-cosmi-uvr-he-orizzontaleverticale-mh","title":"Heat Recovery Ventilator Fantini Cosmi UVR-HE HORIZONTAL\/vertical 750 m³\/h","description":"\u003cp\u003eThe \u003cstrong\u003eFantini Cosmi UVR 700 MF HE\u003c\/strong\u003e heat recovery unit is a dual-flow ventilation unit for installation in a false ceiling and\/or on the floor, with airflow from \u003cstrong\u003e650 to 1600 m³\/h\u003c\/strong\u003e, M6 and F7 filters and an included control unit. It provides ventilation for small and medium-sized bars, restaurants, offices, meeting rooms, shops, gyms, dance halls and canteens.\u003c\/p\u003e\u003cp\u003e\u003cimg alt=\"Grey sheet-metal heat recovery unit with two round vents on the front and an electrical panel with a red switch\" style=\"float: none; display: block; margin-left: auto; margin-right: auto;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0902\/2177\/3121\/files\/UVR-HE_d2f635b9-a2b6-4e39-9c56-f960354b26ff_600x600.jpg?v=1747427878\"\u003e\u003c\/p\u003e\u003ch2\u003eHigh-efficiency single-phase EC fans\u003c\/h2\u003e\u003cp\u003eThe unit uses high-efficiency single-phase EC fans, with speed adjustable progressively and independently for each fan. The forward-curved fans installed in the size 1600 and larger models already meet IE5 and ERP2020 efficiency requirements. The UVR-HE 500, UVR-HE 700 and UVR-HE 1200 models have backward-curved centrifugal fans.\u003c\/p\u003e\u003ch2\u003eCross-flow recovery in 23 mm insulated casing\u003c\/h2\u003e\u003cp\u003eThe high-efficiency cross-flow recovery unit works inside an external structure in galvanised sheet steel, with a thermo-acoustic panel in 23 mm expanded polyurethane at 40 kg\/m³ density. A fire-retardant sound-absorbing mat is placed on the lower and upper panels.\u003c\/p\u003e\u003ch2\u003eM6 and F7 filters, clogging alert\u003c\/h2\u003e\u003cp\u003eThe M6 filter is on the outdoor air intake and the F7 filter on the fresh air supply. Both are inspectable and replaceable through the access panels in the cover. A pressure switch on the supply filters and an LED light on the control unit signal clogging.\u003c\/p\u003e\u003csection data-ai-faq=\"1\" itemscope itemtype=\"https:\/\/schema.org\/FAQPage\"\u003e\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\u003csummary itemprop=\"name\"\u003eWhere is the Fantini Cosmi UVR 700 MF HE installed?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003eThe Fantini Cosmi UVR 700 MF HE is installed in a false ceiling and\/or on the floor, and the airflow configuration can also be defined on site.\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\u003csummary itemprop=\"name\"\u003eWhich filters does the Fantini Cosmi UVR 700 MF HE have?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003eIt has an M6 filter on the outdoor air intake and an F7 filter on the fresh air supply, both inspectable and replaceable through the access panels in the cover.\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\u003csummary itemprop=\"name\"\u003eCan the Fantini Cosmi UVR 700 MF HE be connected to an external control system?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003eThe RS485 port of the Fantini Cosmi UVR 700 MF HE is compatible with the MODBUS interface and allows connection of a DeG remote control, including in series with other DeG base boards.\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\u003csummary itemprop=\"name\"\u003eIs a CO2 sensor needed to control ventilation on the Fantini Cosmi UVR 700 MF HE?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003eThe control board is prepared for a CO2 or humidity sensor, both optional: with a CO2 sensor installed, ventilation is adjusted according to air quality.\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\u003csummary itemprop=\"name\"\u003eIn which premises is the Fantini Cosmi UVR 700 MF HE used?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003eIt is designed for ventilating small and medium-sized bars, restaurants, offices, meeting rooms, shops, gyms, dance halls and canteens.\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\u003csummary itemprop=\"name\"\u003eWhat does the Fantini Cosmi UVR 700 MF HE control unit include?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003eThe control unit is included, has an LCD display, controls the bypass in manual and automatic mode, and is flush-mounted in a 3-module type 503 box.\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003c\/section\u003e\u003ch2\u003eMotorised bypass and temperature probes\u003c\/h2\u003e\u003cp\u003eThe motorised bypass damper can be controlled both manually and automatically. Two temperature probes measure the supply air and the return air. The control board is prepared for a CO2 or humidity sensor, both optional.\u003c\/p\u003e\u003ch2\u003eControl unit and RS485 port\u003c\/h2\u003e\u003cp\u003eThe control unit is included, has an LCD display and is flush-mounted in a 3-module type 503 box. It manages the two fans in coupled or separate mode, monitors outdoor and indoor temperature and, with a CO2 sensor installed, adjusts ventilation according to air quality. The RS485 port allows connection of a DeG remote control, is compatible with the MODBUS interface and allows series connection with other DeG base boards.\u003c\/p\u003e\u003ch2\u003eIP55 panel and on-site installation\u003c\/h2\u003e\u003cp\u003eThe electrical control panel is installed on board with IP55 protection. The airflow configuration can also be defined on site, and the mounting brackets are included in the structure. The condensate collection tray has a drain tube in transparent plastic.\u003c\/p\u003e\u003cp\u003e\u003cimg height=\"157\" width=\"1257\" alt=\"Technical table with codes and electrical and acoustic data of two heat recovery unit models\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0902\/2177\/3121\/files\/solo750_26c15b6d-5b85-4dd7-b724-b4c49596f65b.jpg?v=1747427892\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/p\u003e\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eModel and codes\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eModel: UVR 700 MF HE\u003c\/li\u003e\n\u003cli\u003eSeries: UVR-HE 750\u003c\/li\u003e\n\u003cli\u003eConfiguration: horizontal\/vertical\u003c\/li\u003e\n\u003cli\u003eInstallation: in a false ceiling and\/or on the floor\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003ePerformance\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eAirflow: from 650 to 1600 m³\/h\u003c\/li\u003e\n\u003cli\u003eRecovery: high-efficiency cross-flow\u003c\/li\u003e\n\u003cli\u003eFans: high-efficiency single-phase EC\u003c\/li\u003e\n\u003cli\u003eForward-curved fans (size 1600 and larger): IE5 and ERP2020\u003c\/li\u003e\n\u003cli\u003eBackward-curved centrifugal fans: UVR-HE 500, UVR-HE 700, UVR-HE 1200\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eStructure and insulation\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eExternal structure: galvanised sheet steel\u003c\/li\u003e\n\u003cli\u003eInsulation: expanded polyurethane, 23 mm thickness, 40 kg\/m³ density\u003c\/li\u003e\n\u003cli\u003eMat: fire-retardant sound-absorbing, on the lower and upper panels\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eFilters\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eOutdoor air intake filter: M6\u003c\/li\u003e\n\u003cli\u003eFresh air supply filter: F7\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eControl and panel\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eControl unit: included, with LCD display\u003c\/li\u003e\n\u003cli\u003eControl unit mounting: flush-mounted, 3-module type 503 box\u003c\/li\u003e\n\u003cli\u003eControl panel: IP55, on board\u003c\/li\u003e\n\u003cli\u003ePort: RS485 (DeG remote control, MODBUS)\u003c\/li\u003e\n\u003cli\u003eFunctions: motorised bypass damper, supply filter pressure switch, two temperature probes, mounting brackets included, condensate tray with drain tube\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eAccessories\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eAvailable accessories: hydronic post-heating coils, hydronic post-cooling coils, electric pre- and post-heating coils\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fantini Cosmi","offers":[{"title":"Default Title","offer_id":44284418523190,"sku":"50146352","price":3430.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0636\/9299\/6662\/files\/25257.jpg?v=1764735500","url":"https:\/\/buytutto.com\/en-eu\/products\/heat-recovery-ventilator-fantini-cosmi-uvr-he-horizontal-vertical-750-m3h","provider":"BuyTutto.com","version":"1.0","type":"link"}