{"product_id":"recuperatore-di-calore-fantini-cosmi-uvr-he-orizzontaleverticale-1200-mh","title":"Heat Recovery Ventilator Fantini Cosmi UVR-HE HORIZONTAL\/vertical 1200 m³\/h","description":"\u003cp\u003e\u003cstrong\u003eFantini Cosmi UVR 1200 MF HE\u003c\/strong\u003e is a twin-flow heat recovery unit for ventilating commercial and service-sector premises, installable in the false ceiling and\/or on the floor, with airflow from \u003cstrong\u003e650 to 1600 m³\/h\u003c\/strong\u003e. It has a high-efficiency cross-flow recuperator and single-phase EC fans. It is used in bars, restaurants, offices, meeting rooms, shops, gyms, dance halls and small to medium-sized canteens.\u003c\/p\u003e\u003ch2\u003eHigh-efficiency single-phase EC fans\u003c\/h2\u003e\u003cp\u003eThe Fantini Cosmi UVR 1200 MF HE is equipped with the new high-efficiency single-phase EC fans. The forward-curved fans fitted to the 1600 size and above already meet \u003cstrong\u003eIE5 and ERP2020\u003c\/strong\u003e efficiency requirements. The speed of each fan is adjustable progressively and independently of the other.\u003c\/p\u003e\u003ch2\u003eGalvanised sheet structure with 23 mm insulation\u003c\/h2\u003e\u003cp\u003e\u003cimg alt=\"Grey sheet-metal heat recovery unit with two round ducts on the front and an electrical panel with a red switch\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0902\/2177\/3121\/files\/UVR-HE_d2f635b9-a2b6-4e39-9c56-f960354b26ff_600x600.jpg?v=1747427878\" style=\"float: none; display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/p\u003e\u003cp\u003eThe external structure is made of galvanised steel sheet, with a thermo-acoustic panel in \u003cstrong\u003eexpanded polyurethane\u003c\/strong\u003e 23 mm thick and 40 kg\/m³ density. A flame-retardant sound-absorbing mat is placed on the lower and upper panels.\u003c\/p\u003e\u003ch2\u003eM6 and F7 filters accessible from the cover\u003c\/h2\u003e\u003cp\u003eThe \u003cstrong\u003eM6 filter\u003c\/strong\u003e is on the outdoor air intake and the \u003cstrong\u003eF7 filter\u003c\/strong\u003e is on the fresh air supply outlet. Both are inspected and replaced through the dedicated access panels in the unit covers. A pressure switch monitors clogging of the supply filters, and an LED on the control unit shows their status.\u003c\/p\u003e\u003csection data-ai-faq=\"1\" itemscope itemtype=\"https:\/\/schema.org\/FAQPage\"\u003e\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\u003csummary itemprop=\"name\"\u003eWhat is the Fantini Cosmi UVR 1200 MF HE recovery unit?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003eIt is a twin-flow ventilation unit with a high-efficiency cross-flow heat recovery unit, with airflow from 650 to 1600 m³\/h in the UVR HE series.\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\u003csummary itemprop=\"name\"\u003eWhere is the UVR 1200 MF HE recovery unit installed?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003eThe Fantini Cosmi UVR 1200 MF HE is installed in the false ceiling and\/or on the floor, and the airflow configuration can also be chosen on site.\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\u003csummary itemprop=\"name\"\u003eWhich filters does the Fantini Cosmi UVR 1200 MF HE have?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003eThe Fantini Cosmi UVR 1200 MF HE has an M6 filter on the outdoor air intake and an F7 filter on the fresh air supply outlet, both replaceable through the cover access panels.\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\u003csummary itemprop=\"name\"\u003eHow do you know when the UVR 1200 MF HE recovery unit filters are clogged?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003eThe Fantini Cosmi UVR 1200 MF HE has a pressure switch that monitors clogging of the supply filters, and an LED on the control unit that shows their status.\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\u003csummary itemprop=\"name\"\u003eCan the UVR 1200 MF HE recovery unit be connected to a building management system?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003eYes, the Fantini Cosmi UVR 1200 MF HE has an RS485 port compatible with the MODBUS interface and allows serial connection to other DeG base boards.\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\u003csummary itemprop=\"name\"\u003eCan a CO2 sensor be added to the UVR 1200 MF HE recovery unit?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003eYes, the control board of the Fantini Cosmi UVR 1200 MF HE is prepared for a CO2 or humidity probe, both optional.\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003c\/section\u003e\u003ch2\u003eMotorised bypass and two temperature sensors\u003c\/h2\u003e\u003cp\u003eThe motorised bypass damper can be controlled both manually and automatically. Two temperature sensors measure the supply air and the return air, and the control also measures outdoor and indoor temperature.\u003c\/p\u003e\u003ch2\u003eControl unit with LCD display included\u003c\/h2\u003e\u003cp\u003eThe \u003cstrong\u003econtrol unit included\u003c\/strong\u003e has an LCD display and manages manual and automatic operation. It is flush-mounted in 3-module type 503 boxes and controls the bypass and the two fans in coupled or separate mode. The electrical panel is installed on board with IP55 rating.\u003c\/p\u003e\u003ch2\u003eRS485 port compatible with MODBUS\u003c\/h2\u003e\u003cp\u003eThe Fantini Cosmi UVR 1200 MF HE has an \u003cstrong\u003eRS485 port\u003c\/strong\u003e to connect a single DeG remote control, for the MODBUS interface or in series with other DeG base boards, allowing you to manage several units with a single remote control.\u003c\/p\u003e\u003cp\u003e\u003cimg height=\"192\" width=\"1256\" alt=\"Technical data table for the three UVR HE heat recovery unit models, with airflows, pressures, power and sound level\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0902\/2177\/3121\/files\/solo1120_6260b57b-707e-4106-8f5a-188fbdd5137e.jpg?v=1747427901\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/p\u003e\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eModel and codes\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eModel: UVR 1200 MF HE\u003c\/li\u003e\n\u003cli\u003eSeries: UVR 1200 MF HE\u003c\/li\u003e\n\u003cli\u003eConfiguration: horizontal\/vertical\u003c\/li\u003e\n\u003cli\u003eController: included\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003ePower and performance\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eAirflow: 650 to 1600 m³\/h (series)\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEnergy efficiency\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eFans: high-efficiency single-phase EC\u003c\/li\u003e\n\u003cli\u003eForward-curved fans (from size 1600): IE5 and ERP2020\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMaterials and construction\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eExternal structure: galvanised steel sheet\u003c\/li\u003e\n\u003cli\u003eInsulation: expanded polyurethane, 23 mm thickness, 40 kg\/m³ density\u003c\/li\u003e\n\u003cli\u003eSound-absorbing mat: flame-retardant, on the lower and upper panels\u003c\/li\u003e\n\u003cli\u003eRecuperator: high-efficiency cross-flow\u003c\/li\u003e\n\u003cli\u003eBackward-curved centrifugal fans: models UVR-HE 500, UVR-HE 700, UVR-HE 1200\u003c\/li\u003e\n\u003cli\u003eForward-curved centrifugal fans: models from UVR-HE 1600 to UVR-HE 8500\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eFilters and control\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eOutdoor air intake filter: M6\u003c\/li\u003e\n\u003cli\u003eFresh air supply filter: F7\u003c\/li\u003e\n\u003cli\u003ePressure switch: monitors clogging of the supply filters\u003c\/li\u003e\n\u003cli\u003eLED: filter clogging status\u003c\/li\u003e\n\u003cli\u003eTwo temperature sensors: supply air and return air\u003c\/li\u003e\n\u003cli\u003eCO2 or humidity sensor: prepared, optional\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eControls and connections\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eControl unit: included, with LCD display\u003c\/li\u003e\n\u003cli\u003eControl unit mounting: flush-mounted in 3-module type 503 box\u003c\/li\u003e\n\u003cli\u003eElectrical panel: on board, IP55\u003c\/li\u003e\n\u003cli\u003eRS485 port: 1\u003c\/li\u003e\n\u003cli\u003eCompatibility: MODBUS interface\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eInstallation: in the false ceiling and\/or on the floor\u003c\/li\u003e\n\u003cli\u003eAirflow configuration: can also be chosen on site\u003c\/li\u003e\n\u003cli\u003eMounting brackets: included in the structure\u003c\/li\u003e\n\u003cli\u003eCondensate collection tray: present, with transparent plastic drain tube\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eAccessories\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eHydronic coils: post-heating, post-cooling\u003c\/li\u003e\n\u003cli\u003eElectric coils: pre- and post-heating\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fantini Cosmi","offers":[{"title":"Default Title","offer_id":44284418293814,"sku":"50146369","price":3822.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0636\/9299\/6662\/files\/25258.jpg?v=1764735481","url":"https:\/\/buytutto.com\/en-eu\/products\/heat-recovery-ventilator-fantini-cosmi-uvr-he-horizontal-vertical-1200-m3h","provider":"BuyTutto.com","version":"1.0","type":"link"}