Ferroli
Ferroli Fan Coil Unit Jolly Top Series VM700 With Free Switch

What size do I need?
For heat pumps and fan coils the right output is worked out by the installer on your home: heat loss, system, climate zone. Send us your measurements and we will reply with a quote.
Couldn't load pickup availability
Shipping and delivery
Shipping and delivery
Timing. With online payment, your order leaves with express courier and arrives within 1-2 working days. In remote areas and on islands, a few extra days may be needed: the estimated delivery date for your postcode is shown under “When it arrives”.
Costs. For orders under €80, shipping costs €8. Delivery to your floor is available for an additional charge.
Availability. Each product shows whether it is in stock, whether only a few units are left, or whether it is sold out; for sold-out products, you can leave your email and we will let you know as soon as they are back in stock.
Your order. You can track it from your account. For any questions, you will find our contact details on the Contact page; all the terms are on the Shipping page.
Support before and after purchase
Support before and after purchase
For advice on choosing a product, a technical question or an order already placed, the Buytutto customer service team is available Monday to Friday, 9:00 am to 1:00 pm and 2:00 pm to 6:00 pm.
You can message us on WhatsApp using the button on this page, or use the contact details on the Contact page. For a product you have already received, open a request from the Support page.
Description
The Ferroli Jolly Top VM700 is a fan coil unit with casing for residential heating and cooling, with a maximum total cooling capacity of 6 kW, a maximum airflow of 1190 m³/h and a depth of 200 mm.

3-speed centrifugal fan
The 3-speed AC motor has a run capacitor always engaged, is coupled directly to the fans and is cushioned by elastic mountings. The double-inlet centrifugal fans have long-profile blades to achieve high airflow at a low rotational speed.
From 3.71 to 6 kW across the three speeds
In cooling, the total capacity is 3.71 kW at minimum speed with 555 m³/h, 5.03 kW at medium with 855 m³/h and 6 kW at maximum with 1190 m³/h. In heating, the heating capacity is 3.8 kW at minimum, 5.1 kW at medium and 6.15 kW at maximum.
3-row coil, with an extra row for 4-pipe systems
The 3-row coil is made of copper tube with aluminium fins, locked in place by mechanical expansion of the tubes. The headers at the top have air vents, and those at the bottom have a water drain valve. For 4-pipe systems, an additional 1-row coil can be fitted as an accessory.
Installable vertically and horizontally
The condensate drip tray is made of thermoplastic material, to prevent corrosion, and is present on both sides: the Ferroli Jolly Top VM700 can be installed vertically or horizontally. The water connections are ¾ inch gas female on the left side, and the coil, which can be rotated, can be moved to have them on the right side.

VM casing and VN recessed version
The VM version casing is made of steel sheet painted with epoxy powder and anti-UV thermoplastic material, in RAL 9003 colour, with grilles and an access panel for the control panel. The VN version, without casing, is for recessed applications and has a closing panel fitted at the front of the fan assembly.
Galvanised sheet steel structure and washable filter
The supporting structure is in galvanised sheet steel of adequate thickness. The air filter is easy to remove and can be regenerated with a simple wash in water.
Frequently asked questions
What environments is the Ferroli Jolly Top VM700 suitable for?
What is the difference between the VM and VN versions?
Can the air filter be cleaned?
Can the Ferroli Jolly Top VM700 be used on a 4-pipe system?
Can the water connections of the Ferroli Jolly Top VM700 be moved?
How noisy is the Ferroli Jolly Top VM700 at its different speeds?
Technical specifications
| Model and codes | |
| Model | Jolly Top Series VM700 |
| Product code | 2CO9A34F |
| Power and performance | |
| Total cooling capacity max | 6 kW |
| Total cooling capacity med | 5.03 kW |
| Total cooling capacity min | 3.71 kW |
| Heating capacity max | 6.15 kW |
| Heating capacity med | 5.1 kW |
| Heating capacity min | 3.8 kW |
| Air flow max | 1190 m³/h |
| Air flow med | 855 m³/h |
| Air flow min | 555 m³/h |
| Electrical consumption | |
| Absorbed power max | 123 W |
| Absorbed power med | 98 W |
| Absorbed power min | 68 W |
| Absorbed current max | 0.53 A |
| Absorbed current med | 0.43 A |
| Absorbed current min | 0.30 A |
| Noise level | |
| Sound power max | 64 dB(A) |
| Sound power med | 56 dB(A) |
| Sound power min | 45 dB(A) |
| Installation and dimensions | |
| Power supply (V-ph-Hz) | 230-1-50 |
| Dimensions (H x W x D) | 495 x 1360 x 200 mm |
| Water connections | ¾ gas female, left side |
| Installation | vertical or horizontal |
| Materials | |
| Structure | galvanised sheet steel |
| Coil | copper tube and aluminium fins |
| Condensate drip tray | thermoplastic material |
| Casing (VM only) | painted steel sheet with epoxy powder and anti-UV thermoplastic |
| Casing colour | RAL 9003 |
| Features and equipment | |
| Fan | double-inlet centrifugal, 3 speeds |
| Air filter | washable and removable |
| Auxiliary coil | 1 row, accessory for 4-pipe systems |
| Versions | VM with casing, VN without casing for recessed installation |
| Included | speed switch free of charge |