{"product_id":"ventilconvettore-fan-coil-aermec-da-incasso-modello-fcz-p-300","title":"Fan Coil Unit Aermec Recessed Model FCZ-P 300 Without Control","description":"\u003cp\u003eThe \u003cstrong\u003eAermec FCZ-P 300\u003c\/strong\u003e is a recessed fan coil unit with no onboard control, for 2- or 4-pipe systems. It can be installed vertically or horizontally and pairs with any heat generator, including low-temperature ones. It is available in the FCZ_P, FCZ_PO and FCZ_PPC versions.\u003c\/p\u003e\u003cp\u003e\u003cimg alt=\"Recessed metal ceiling fan coil unit with finned-tube coil and grey sheet metal panels\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0902\/2177\/3121\/files\/Screenshot_2025-06-12_093224_600x600.png?v=1749713552\" style=\"float: none; display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/p\u003e\u003ch2\u003eThree-speed centrifugal fan\u003c\/h2\u003e\u003cp\u003eThe FCZ-P 300 fan is centrifugal and has three speeds. The electric motors have permanently engaged capacitors.\u003c\/p\u003e\u003ch2\u003eRemovable class G2 air filter\u003c\/h2\u003e\u003cp\u003eThe class G2 air filter is fitted in all versions and is easy to remove and clean. In the FCZ_PPC versions, air purification is handled by the Plasmacluster purifier. The volutes can be removed and inspected for easy, effective cleaning.\u003c\/p\u003e\u003csection data-ai-faq=\"1\" itemscope itemtype=\"https:\/\/schema.org\/FAQPage\"\u003e\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\u003csummary itemprop=\"name\"\u003eIs the FCZ-P 300 fan coil unit suitable for 2-pipe systems?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003eYes, the Aermec FCZ-P 300 can be installed in 2- or 4-pipe systems.\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\u003csummary itemprop=\"name\"\u003eWhich heat generators is the FCZ-P 300 compatible with?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003eThe Aermec FCZ-P 300 fan coil unit pairs with any heat generator, including low-temperature ones.\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\u003csummary itemprop=\"name\"\u003eCan the FCZ-P 300 be installed vertically and horizontally?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003eThe Aermec FCZ-P 300 fan coil unit can be installed both vertically and horizontally.\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\u003csummary itemprop=\"name\"\u003eWhat filter does the FCZ-P 300 have and how is it cleaned?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003eThe Aermec FCZ-P 300 fan coil unit has a class G2 air filter, which is easy to remove and clean in all versions, and volutes that can be removed and inspected.\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\u003csummary itemprop=\"name\"\u003eWhat is the difference in the FCZ_PPC version of the FCZ-P 300?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003eThe FCZ_PPC version of the Aermec FCZ-P 300 fan coil unit includes the Plasmacluster purifier, which purifies the air.\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\u003csummary itemprop=\"name\"\u003eWhich recessed installation frame goes with which fan coil series?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003eThe CHU-L recessed installation frame is for the Omnia UL-P series, while the CHF is for the FCX-P, FCX-PV and FCXI-P series in 2-pipe, 2-pipe with electric heater and 4-pipe systems.\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003c\/section\u003e\u003ch2\u003eLow pressure-drop coil\u003c\/h2\u003e\u003cp\u003eThe heat exchange coils have a low pressure drop. The water connection side can be chosen from the configurable versions, but it cannot be reversed on units with a secondary coil.\u003c\/p\u003e\u003ch2\u003eRecessed installation frame for a concealed wall niche\u003c\/h2\u003e\u003cp\u003eThe recessed installation frame is available as an accessory. It is a galvanised sheet metal template that creates the space for the fan coil unit in the wall, making masonry work easier during construction of the niche. Once the work is finished, the fan coil unit remains completely hidden from view.\u003c\/p\u003e\u003cp\u003eThe recessed installation frame comes in two versions: the CHU-L for the Omnia UL-P fan coil series, and the CHF for the FCX-P, FCX-PV and FCXI-P series in 2-pipe, 2-pipe with electric heater and 4-pipe systems.\u003c\/p\u003e\u003cp\u003e\u003cimg alt=\"Table of heating and cooling performance, fan\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0902\/2177\/3121\/files\/Screenshot_2025-06-12_093057_1024x1024.png?v=1749713470\" style=\"float: none; display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/p\u003e\u003cp\u003e\u003cimg alt=\"Table of dimensions and weights for a fan coil unit series, with a technical drawing of the unit alongside\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0902\/2177\/3121\/files\/Screenshot_2025-06-12_093149_1024x1024.png?v=1749713516\" style=\"float: none; display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/p\u003e\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eModel: Aermec FCZ-P 300 recessed fan coil unit without control\u003c\/li\u003e\n\u003cli\u003eVersions: FCZ_P, FCZ_PO, FCZ_PPC\u003c\/li\u003e\n\u003cli\u003eInstallation: vertical and horizontal\u003c\/li\u003e\n\u003cli\u003eSystems: 2- or 4-pipe\u003c\/li\u003e\n\u003cli\u003eHeat generator: any type, including low-temperature ones\u003c\/li\u003e\n\u003cli\u003eControl: no onboard control\u003c\/li\u003e\n\u003cli\u003eFan: three-speed centrifugal\u003c\/li\u003e\n\u003cli\u003eAir filter: class G2\u003c\/li\u003e\n\u003cli\u003eAir purification: Plasmacluster purifier in the FCZ_PPC versions\u003c\/li\u003e\n\u003cli\u003eWater connection side: selectable from the configurable versions, not reversible for units with a secondary coil\u003c\/li\u003e\n\u003cli\u003eAccessory: CHU-L or CHF recessed installation frame\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Aermec","offers":[{"title":"Default Title","offer_id":44284757082166,"sku":"99548186","price":329.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0636\/9299\/6662\/files\/21615.jpg?v=1764749538","url":"https:\/\/buytutto.com\/en-eu\/products\/fan-coil-unit-aermec-recessed-model-fcz-p-300","provider":"BuyTutto.com","version":"1.0","type":"link"}