{"product_id":"stazione-di-sollevamento-dab-per-raccolta-acque-reflue-modello-fekabox-200","title":"Dab Wastewater Collection Lift Station Model Fekabox 200","description":"\u003cp\u003eThe Dab FEKABOX 200 is a lifting station for collecting domestic wastewater, with a 200-litre LLDPE tank. It serves garages and basements located below the sewer network, where drainage cannot flow by gravity: the pump in the tank pushes the water up into the sewer.\u003c\/p\u003e\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0902\/2177\/3121\/files\/41MuqxcayQL-_SL500_f013bcd1-4831-4aa2-818f-dbab19b08a28.jpg?v=1747422842\" alt=\"Underground lifting station in green plastic with upper cover\" width=\"456\" height=\"500\"\u003e\u003c\/p\u003e\u003ch2\u003eDischarge into the sewer with a pump inside the tank\u003c\/h2\u003e\u003cp\u003eThe pump installed inside the tank lifts the water up to the sewer. The tank is set up for numerous inlet, outlet and ventilation connection options, so it also suits limited spaces. The range is designed for a single automatic single-phase pump with float switch, to be ordered separately without control panel.\u003c\/p\u003e\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0902\/2177\/3121\/files\/fekabox_200-400x400_ea24c290-7262-4d8c-8ba6-a29bb8f55b86.jpg?v=1747422847\" alt=\"Green tank of a lifting station with grey submersible pump and black delivery pipe, sectional view\" width=\"400\" height=\"400\"\u003e\u003c\/p\u003e\u003ch2\u003eLow-noise motor, water-cooled\u003c\/h2\u003e\u003cp\u003eThe motor is low-noise and water-cooled. The manufacturer specifies the FEKA VS 900 pump for this station, to be ordered separately.\u003c\/p\u003e\u003csection data-ai-faq=\"1\" itemscope itemtype=\"https:\/\/schema.org\/FAQPage\"\u003e\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\u003csummary itemprop=\"name\"\u003eIs the Fekabox 200 suitable for garages or basements?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003eYes, the Dab FEKABOX 200 is designed for installations located below the sewer network, such as garages or basements, where water cannot be discharged by gravity.\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\u003csummary itemprop=\"name\"\u003eWhat water can the Fekabox 200 lifting station handle?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003eThe Dab FEKABOX 200 lifting station handles groundwater, rainwater, clear waste water, black waste water and river or lake water, with a maximum liquid temperature of 45°C.\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\u003csummary itemprop=\"name\"\u003eWhere is the Fekabox 200 lifting station installed?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003eThe Dab FEKABOX 200 is fixed to the floor if inside a building and buried if outside; it is not trafficable and can only be walked on up to 100 kg.\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\u003csummary itemprop=\"name\"\u003eDo I need a separate pump with the Fekabox 200?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003eYes, the pump for the Dab FEKABOX 200 must be ordered separately, without control panel; the manufacturer specifies the FEKA VS 900 pump.\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\u003csummary itemprop=\"name\"\u003eWhat are the connections on the Fekabox 200 lifting station?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003eThe Dab FEKABOX 200 has DN 50\/110 inlets, DN 50 ventilation and a G2” outlet, with lifting kit and float cable grip for FEKA VS and VX pumps.\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003c\/section\u003e\u003ch2\u003eIntegrated overflow switch and external display\u003c\/h2\u003e\u003cp\u003eThe overflow switch is integrated into the station. The external display shows control, operating mode, start and stop, and alarms.\u003c\/p\u003e\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0902\/2177\/3121\/files\/Screenshot_2025-06-16_122225.png?v=1750069362\" alt=\"Dimensioned technical drawing of a wastewater lifting station\"\u003e\u003c\/p\u003e\u003ch2\u003eTechnical data sheet\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMaterial: LLDPE\u003c\/li\u003e\n\u003cli\u003eCapacity: 200 litres\u003c\/li\u003e\n\u003cli\u003eStandard: 12050-1\u003c\/li\u003e\n\u003cli\u003eInlets: DN 50\/110\u003c\/li\u003e\n\u003cli\u003eVentilation: DN 50\u003c\/li\u003e\n\u003cli\u003eOutlet: G2”\u003c\/li\u003e\n\u003cli\u003eInstallation type: outdoor, for untreated wastewater, when the sewer cannot be reached by gravity\u003c\/li\u003e\n\u003cli\u003eOperating range: from 1 to 24 m³\/h with head up to 15 m\u003c\/li\u003e\n\u003cli\u003ePumped liquid: groundwater, rainwater, clear waste water, black waste water and river or lake water\u003c\/li\u003e\n\u003cli\u003eMaximum liquid temperature: 45°C\u003c\/li\u003e\n\u003cli\u003eInstallation: fixed to the floor if inside a building; buried if outside a building\u003c\/li\u003e\n\u003cli\u003eTrafficability: not trafficable, walkable only up to 100 kg\u003c\/li\u003e\n\u003cli\u003eMotor: low-noise, water-cooled\u003c\/li\u003e\n\u003cli\u003ePump: FEKA VS 900 (to be ordered separately)\u003c\/li\u003e\n\u003cli\u003eOverflow switch: integrated\u003c\/li\u003e\n\u003cli\u003eDisplay: external, for control, operating mode, start\/stop and alarms\u003c\/li\u003e\n\u003cli\u003eSupplied with: 2” PP lifting device and anti-rotation bracket for FEKA VS and VX; cable gland for single pump; 2” F x 1 x ¼ M fitting for FEKA 600; float cable grip kit for FEKA VS and VX\u003c\/li\u003e\n\u003cli\u003eNot included: pump, to be selected according to the possible configurations; alarm float support\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Dab","offers":[{"title":"Default Title","offer_id":44284538716214,"sku":"99330958","price":538.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0636\/9299\/6662\/files\/21469.jpg?v=1764741915","url":"https:\/\/buytutto.com\/en-eu\/products\/dab-wastewater-collection-lift-station-fekabox-200","provider":"BuyTutto.com","version":"1.0","type":"link"}