{"product_id":"elettropompa-dab-per-gruppi-di-pressurizzazione-con-2-pompe-centrifughe-bigiranti-2k55100t","title":"DAB Electric Pump for Pressure Boosting Sets with 2 Twin-Impeller Centrifugal Pumps 2 K 55\/100 T - 2x3 HP","description":"\u003cp\u003eThe Dab 2K55\/100T is a pressure booster set with two K-series two-stage centrifugal electric pumps, 3 HP each (2x3 HP), for small and medium civil water systems. The operating range runs from 1 to 19 m3\/h, with a maximum working pressure of PN10. The set comes with diaphragm tanks and an IP55 control panel with dry-run protection.\u003c\/p\u003e\u003cp\u003e\u003cimg alt=\"Pressure booster set with two green pumps mounted on a metal frame\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0902\/2177\/3121\/files\/new_-img_low_2_k_0-400x400_600x600.jpg?v=1750249026\" style=\"float: none; display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/p\u003e\u003ch2\u003eTwo pumps with ball and check valves on each\u003c\/h2\u003e\u003cp\u003eEach electric pump has ball valves with union fittings on the suction and delivery sides, and a check valve on the suction side. The 1 1\/4\" connections for the air supply are on the suction side of each pump, while the suction and delivery manifolds are in tropicalised galvanised steel.\u003c\/p\u003e\u003ch2\u003eIP55 panel with dry-run and overload protection\u003c\/h2\u003e\u003cp\u003eThe panel, housed in a self-extinguishing thermoplastic enclosure, protects the pumps from overloads and overtemperature, with automatic reset, and from overcurrents, abnormal voltages, dry running and rapid starts. The main isolator has a lockable door interlock.\u003c\/p\u003e\u003csection data-ai-faq=\"1\" itemscope itemtype=\"https:\/\/schema.org\/FAQPage\"\u003e\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\u003csummary itemprop=\"name\"\u003eWhich systems is the Dab 2K55\/100T suitable for?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003eThe Dab 2K55\/100T is designed for small and medium civil water systems, with an operating range of 1 to 19 m3\/h and a maximum working pressure of PN10.\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\u003csummary itemprop=\"name\"\u003eWhich liquids can the Dab 2K55\/100T group pump?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003eThe liquid must be clean, free from solid or abrasive substances, non-viscous, non-aggressive and chemically neutral, close to the characteristics of water. The liquid temperature ranges from -10 °C to +70 °C.\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\u003csummary itemprop=\"name\"\u003eDoes the Dab 2K55\/100T panel protect against dry running?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003eYes, the Dab 2K55\/100T panel protects the pumps against dry running, and can be connected to a protective pressure switch or float kit, to be ordered separately as an option.\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\u003csummary itemprop=\"name\"\u003eCan the Dab 2K55\/100T be connected to an overpressure pressure switch?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003eYes, the Dab 2K55\/100T panel is prepared for connection of an overpressure cut-off pressure switch kit, to be ordered separately as an option.\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\u003csummary itemprop=\"name\"\u003eWhat is included in the Dab 2K55\/100T package?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003eThe Dab 2K55\/100T set is supplied in a sturdy cardboard box on a wooden pallet, with installation and maintenance instructions and a wiring diagram.\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\u003csummary itemprop=\"name\"\u003eWhat is the maximum ambient temperature of the Dab 2K55\/100T?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003eThe maximum ambient temperature of the Dab 2K55\/100T is +40 °C, with protection rating IP44 for the set and IP55 for the panel.\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003c\/section\u003e\u003ch2\u003eControls and indicators on the panel front\u003c\/h2\u003e\u003cp\u003eThe front has AUT, OFF and MAN buttons, alarm RESET buttons, the display and run, lock and alarm indicator lights. Inside there are N.O. contacts for alarm signalling.\u003c\/p\u003e\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0902\/2177\/3121\/files\/2k_4cce3af3-2ed4-4ba7-abf3-dada0f8d8081.jpg?v=1747422782\" alt=\"Table of double-pump pressure booster set models, with power ratings, power supply and flow rate\" width=\"532\" height=\"753\"\u003e\u003c\/p\u003e\u003ch2\u003eTechnical data sheet\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eModel: Dab 2K55\/100T\u003c\/li\u003e\n\u003cli\u003ePumps: 2 K-series two-stage centrifugal electric pumps, 2x3 HP\u003c\/li\u003e\n\u003cli\u003eOperating range: from 1 to 19 m3\/h\u003c\/li\u003e\n\u003cli\u003ePumped liquid: clean, free from solid or abrasive substances, non-viscous, non-aggressive, non-crystallising and chemically neutral, close to the characteristics of water\u003c\/li\u003e\n\u003cli\u003eLiquid temperature: from -10 °C to +70 °C\u003c\/li\u003e\n\u003cli\u003eMaximum ambient temperature: +40 °C\u003c\/li\u003e\n\u003cli\u003eMaximum working pressure: PN10\u003c\/li\u003e\n\u003cli\u003eSet protection rating: IP44\u003c\/li\u003e\n\u003cli\u003ePanel protection rating: IP55\u003c\/li\u003e\n\u003cli\u003eMotors: IE2 as standard from 0.75 kW up to 5.5 kW - IE3 ≥ 7.5 kW\u003c\/li\u003e\n\u003cli\u003eBase: tropicalised galvanised sheet metal with 4 rubber anti-vibration feet\u003c\/li\u003e\n\u003cli\u003eManifolds: threaded suction and delivery manifolds in tropicalised galvanised steel\u003c\/li\u003e\n\u003cli\u003eTanks: 2 diaphragm tanks, standard\u003c\/li\u003e\n\u003cli\u003eValves: ball valves with union fittings on the suction and delivery side for each pump; check valve on the suction side for each pump\u003c\/li\u003e\n\u003cli\u003ePlugs: 2 female plugs in tropicalised galvanised cast iron for closing the manifolds\u003c\/li\u003e\n\u003cli\u003eConnections: 1 1\/4\" for air supply on the suction side of each pump\u003c\/li\u003e\n\u003cli\u003eTransmitter: 1 pressure transmitter on the delivery manifold\u003c\/li\u003e\n\u003cli\u003ePanel: self-extinguishing thermoplastic enclosure, IP55\u003c\/li\u003e\n\u003cli\u003eFront panel components: main isolator with lockable door interlock; AUT - OFF - MAN buttons; alarm RESET buttons; display; run, lock and alarm indicator lights\u003c\/li\u003e\n\u003cli\u003eInternal panel components: electronic control and command board with fuses and contactors; single-phase or three-phase power terminals; terminals for dry-running or overpressure pressure switches (optional); N.O. contacts for alarm signalling; mini DIP switches for function selection\u003c\/li\u003e\n\u003cli\u003eOptional kits to be ordered separately: dry-running protection pressure switch or float; overpressure cut-off pressure switch\u003c\/li\u003e\n\u003cli\u003eProtection functions: overloads and overtemperature with automatic reset; short circuits with fuses (Plus model only); pump overcurrents (ampere-metric protection); abnormal voltages; dry running; rapid starts; pressure sensor fault; inconsistency of external protection controls\u003c\/li\u003e\n\u003cli\u003eSupplied with: sturdy cardboard packaging on a wooden pallet; installation and maintenance instructions with wiring diagram\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Dab","offers":[{"title":"Default Title","offer_id":44284167618614,"sku":"99582111","price":2499.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0636\/9299\/6662\/files\/21464.jpg?v=1764717754","url":"https:\/\/buytutto.com\/en-eu\/products\/dab-pump-pressure-boosting-set-2-twin-impeller-centrifugal-pumps-2k55100t","provider":"BuyTutto.com","version":"1.0","type":"link"}