{"title":"Floor-Standing Boilers","description":"\u003cp\u003e\u003c\/p\u003e","products":[{"product_id":"caldaia-a-condensazione-ferroli-alta-potenza-modello-force-w-120-kw-metano-solo-riscaldamento","title":"Condensing Boiler Ferroli High Output Model Force W 120 kW Natural Gas\/LPG Code 0MDSEAWA - Heating Only","description":"\u003cp\u003e\u003cstrong\u003eFerroli Force W 120 (code 0MDSEAWA)\u003c\/strong\u003e is a high-output condensing boiler for heating only, running on natural gas or LPG, designed for new builds and boiler room refurbishments. It has a \u003cstrong\u003emaximum heat input of 113.00 kW\u003c\/strong\u003e, an \u003cstrong\u003eefficiency of 98.3% at 80-60 °C\u003c\/strong\u003e and \u003cstrong\u003eERP class A\u003c\/strong\u003e, and can be installed in cascade up to four modules for 600 kW in total.\u003c\/p\u003e\u003cp\u003e\u003cimg alt=\"Illustrated panels showing the main features of a condensing boiler: heat account incentive, tax deduction\" style=\"float: none; display: block; margin-left: auto; margin-right: auto;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0902\/2177\/3121\/files\/Screenshot_2025-05-22_122433_600x600.png?v=1747909607\"\u003e\u003c\/p\u003e\u003ch2\u003eUp to 600 kW with four cascaded modules certified by INAIL\u003c\/h2\u003e\u003cp\u003eEach module can be installed on its own or in configurations of up to four units in cascade, for a maximum total output of 600 kW. For configurations of 2, 3 or 4 modules, hydraulic, gas and flue accessories certified by INAIL are available, and the flue kit and accessories are ordered on request.\u003c\/p\u003e\u003cp\u003e\u003cimg alt=\"White wall-mounted condensing boiler with white flue outlet at the top and dark control panel at the bottom\" style=\"float: none; display: block; margin-left: auto; margin-right: auto;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0902\/2177\/3121\/files\/Screenshot_2025-05-22_122418_600x600.png?v=1747909526\"\u003e\u003c\/p\u003e\u003ch2\u003eMonobloc heat exchanger in aluminium-silicon alloy\u003c\/h2\u003e\u003cp\u003eThe monobloc heat exchanger in aluminium-silicon alloy is designed for maximum heat transfer efficiency and low pressure losses in the water circuit.\u003c\/p\u003e\u003ch2\u003ePremix micro-flame burner, Class 6 according to EN 15502-1\u003c\/h2\u003e\u003cp\u003eThe premix combustion unit uses a \u003cstrong\u003emetal fibre micro-flame burner\u003c\/strong\u003e with very low polluting emissions, Class 6 according to EN 15502-1. The Force W 120 runs on natural gas or LPG.\u003c\/p\u003e\u003csection data-ai-faq=\"1\" itemscope itemtype=\"https:\/\/schema.org\/FAQPage\"\u003e\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\u003csummary itemprop=\"name\"\u003eWhat systems is the Ferroli Force W 120 designed for?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003eThe Ferroli Force W 120 is designed for new builds and boiler room refurbishments, that is, for centralised high-output systems.\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\u003csummary itemprop=\"name\"\u003eCan the Ferroli Force W 120 be connected in cascade?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003eThe Ferroli Force W 120 installs on its own or in cascade of up to four modules, for a maximum total output of 600 kW, with INAIL-certified accessories for 2, 3 or 4 modules.\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\u003csummary itemprop=\"name\"\u003eWhich fuels does the Ferroli Force W 120 run on?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003eThe Ferroli Force W 120 runs on natural gas or LPG, as the modules can operate with either fuel.\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\u003csummary itemprop=\"name\"\u003eWhat type of burner does the Ferroli Force W 120 have?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003eThe Ferroli Force W 120 has a premix metal fibre micro-flame burner, with NOx emission class 6 according to EN 15502-1.\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\u003csummary itemprop=\"name\"\u003eWhat protections does the Ferroli Force W 120 have?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003eThe Ferroli Force W 120 has flow and return sensors for constant ΔT operation, heat exchanger over-temperature protection set at 95 °C, a flue gas safety sensor and a water pressure switch with a minimum threshold of 0.8 bar.\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\u003csummary itemprop=\"name\"\u003eWhich accessories go with the Ferroli Force W 120?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003eThe Ferroli Force W 120 pairs with the flue kit and the hydraulic, gas and flue accessories for configurations of 2, 3 or 4 INAIL-certified modules, available on request.\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003c\/section\u003e\u003ch2\u003eProtections on water, flue gas and discharge\u003c\/h2\u003e\u003cp\u003eThe Force W 120 has flow and return sensors for constant ΔT operation and heat exchanger over-temperature protection, set at 95 °C. The flue gas safety sensor and the water pressure switch with a minimum threshold of 0.8 bar complete the protection.\u003c\/p\u003e\u003cp\u003eThe hydraulic group, supplied as an accessory, has isolating valves, one of which is a three-way valve for venting to atmosphere, and is configured with two circulation pumps, standard or high-head. The sealed-chamber air\/flue circuit is certified B23, C13 and C33, and the non-return clapet valve on the flue duct allows the manifold to be sized for pressure.\u003c\/p\u003e\u003ch2\u003eEfficiency and incentives for energy refurbishment\u003c\/h2\u003e\u003cp\u003eThe efficiency of the Force W 120 makes it eligible for the economic incentives available for energy refurbishment of heating systems.\u003c\/p\u003e\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eModel and codes\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eModel: 0MDSEAWA W 120\u003c\/li\u003e\n\u003cli\u003eERP class: A\u003c\/li\u003e\n\u003cli\u003eProtection rating: IPX4D\u003c\/li\u003e\n\u003cli\u003eNOx emission class: 6\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eOutput and performance\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eMaximum heating heat input: 113.00 kW\u003c\/li\u003e\n\u003cli\u003eMinimum heating heat input: 19.0 kW\u003c\/li\u003e\n\u003cli\u003eMaximum heating output 80°C-60°C: 110.5 kW\u003c\/li\u003e\n\u003cli\u003eMinimum heating output 80°C-60°C: 18.7 kW\u003c\/li\u003e\n\u003cli\u003eMaximum useful output 50°C-30°C: 117.00 kW\u003c\/li\u003e\n\u003cli\u003eMinimum useful output 50°C-30°C: 20.05 kW\u003c\/li\u003e\n\u003cli\u003eMaximum heating operating pressure: 6 bar\u003c\/li\u003e\n\u003cli\u003eMinimum heating operating pressure: 0.8 bar\u003c\/li\u003e\n\u003cli\u003eHeating water content: 5.6 l\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEnergy efficiency\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eEfficiency 80°C-60°C: 98.3 \/ 98.3 %\u003c\/li\u003e\n\u003cli\u003eEfficiency 50°C-30°C: 104.8 \/ 108.5 %\u003c\/li\u003e\n\u003cli\u003eEfficiency at 30% partial load: 108.6 %\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDimensions and weight\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eNet weight: 76 kg\u003c\/li\u003e\n\u003cli\u003eDimensions (W x H x D): 610 x 900 x 460\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eInstallation and connections\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eSupply voltage: 230 V \/ 50 Hz\u003c\/li\u003e\n\u003cli\u003eFuel: natural gas or LPG\u003c\/li\u003e\n\u003cli\u003eAir\/flue circuit: sealed chamber, certified B23, C13 and C33\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Ferroli","offers":[{"title":"Default Title","offer_id":44282702561334,"sku":"50148714","price":4058.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0636\/9299\/6662\/files\/31492.jpg?v=1764685230"},{"product_id":"caldaia-a-condensazione-ferroli-alta-potenza-modello-force-w-150-kw-metano-solo-riscaldamento","title":"Condensing Boiler Ferroli High Output Model Force W 150 kW Natural Gas\/LPG Code 0MDSFAWA - Heating Only","description":"\u003cp\u003eThe \u003cstrong\u003eFerroli Force W 150 (code 0MDSFAWA)\u003c\/strong\u003e is a high-output condensing boiler, heating only, designed for new builds and boiler room refurbishments. Each module has a \u003cstrong\u003euseful thermal output of 117.00 kW at 50-30 °C\u003c\/strong\u003e at maximum power, an \u003cstrong\u003eefficiency of 98.3% at 80-60 °C\u003c\/strong\u003e and a \u003cstrong\u003eNOx emission class 6\u003c\/strong\u003e. It runs on natural gas or LPG and can be installed on its own or in cascade up to four modules.\u003c\/p\u003e\u003cp\u003e\u003cimg alt=\"Illustrated panels showing the main features of a condensing boiler: heat account incentive, tax deduction\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0902\/2177\/3121\/files\/Screenshot_2025-05-22_122433_600x600.png?v=1747909607\" style=\"float: none; display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/p\u003e\u003ch2\u003eUp to four cascaded modules for 600 kW in total\u003c\/h2\u003e\u003cp\u003eEach module can be installed on its own or in configurations of up to four units in cascade, for a \u003cstrong\u003emaximum total output of 600 kW\u003c\/strong\u003e. The hydraulic, gas and flue accessories are complete for configurations of 2, 3 or 4 INAIL-certified modules. The FORCE W range is designed for new builds and boiler room refurbishments, and its efficiency makes it eligible for the economic incentives available for energy refurbishment of heating systems.\u003c\/p\u003e\u003cp\u003e\u003cimg alt=\"White wall-mounted condensing boiler with white flue outlet at the top and dark control panel at the bottom\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0902\/2177\/3121\/files\/Screenshot_2025-05-22_122418_600x600.png?v=1747909526\" style=\"float: none; display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/p\u003e\u003ch2\u003eMonobloc heat exchanger in aluminium-silicon alloy\u003c\/h2\u003e\u003cp\u003eThe \u003cstrong\u003emonobloc heat exchanger\u003c\/strong\u003e in aluminium-silicon alloy is designed to achieve maximum heat transfer efficiency and low pressure losses in the water circuit.\u003c\/p\u003e\u003ch2\u003eMetal fibre micro-flame burner, class 6 according to EN 15502-1\u003c\/h2\u003e\u003cp\u003eThe premix combustion unit uses a \u003cstrong\u003emetal fibre burner\u003c\/strong\u003e with a micro-flame and very low polluting emissions. The modules can run on natural gas or LPG.\u003c\/p\u003e\u003csection data-ai-faq=\"1\" itemscope itemtype=\"https:\/\/schema.org\/FAQPage\"\u003e\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\u003csummary itemprop=\"name\"\u003eWhat does the NOx class 6 of the Ferroli Force W 150 mean?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003eThe Ferroli Force W 150 has NOx emission class 6 and a metal fibre micro-flame burner, with very low polluting emissions according to EN 15502-1.\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\u003csummary itemprop=\"name\"\u003eDoes the Ferroli Force W 150 run on natural gas or LPG?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003eYes, the Ferroli Force W 150 can run on natural gas or LPG, with a 230 V and 50 Hz power supply.\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\u003csummary itemprop=\"name\"\u003eHow many Ferroli Force W 150 modules can be put in cascade?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003eThe Ferroli Force W 150 can be installed in cascade of up to four modules, for a maximum total output of 600 kW, with hydraulic, gas and flue accessories certified by INAIL for configurations of 2, 3 or 4 modules.\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\u003csummary itemprop=\"name\"\u003eWhat protections does the Ferroli Force W 150 heat exchanger have?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003eThe Ferroli Force W 150 heat exchanger is protected against over-temperature with a setting of 95 °C, and the water pressure switch has a minimum threshold of 0.8 bar.\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\u003csummary itemprop=\"name\"\u003eHow much does the Ferroli Force W 150 weigh and what are its dimensions?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003eThe Ferroli Force W 150 weighs 76 kg net and measures 610 x 900 x 460 (W x H x D).\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003c\/section\u003e\u003ch2\u003eSafety: flow and return sensors, 95 °C setting and 0.8 bar pressure switch\u003c\/h2\u003e\u003cp\u003eThe flow and return sensors work at constant ΔT. The over-temperature protection of the \u003cstrong\u003eheat exchanger, set at 95 °C\u003c\/strong\u003e, is backed up by the flue gas safety sensor and the water pressure switch with a minimum threshold of 0.8 bar.\u003c\/p\u003e\u003ch2\u003eSealed-chamber air\/flue circuit certified B23, C13 and C33\u003c\/h2\u003e\u003cp\u003eThe air\/flue circuit is a \u003cstrong\u003esealed chamber certified B23, C13 and C33\u003c\/strong\u003e. The non-return clapet valve on the flue discharge duct allows the manifold to be sized for pressure.\u003c\/p\u003e\u003ch2\u003eHydraulic group supplied as an accessory\u003c\/h2\u003e\u003cp\u003eThe hydraulic group is supplied as an accessory, with isolating valves, one of which is a three-way valve for venting to atmosphere. It is configured with two circulation pumps, standard or high-head.\u003c\/p\u003e\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eModel and codes\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eModel: 0MDSFAWA W 150\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEnergy efficiency\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eERP class: A\u003c\/li\u003e\n\u003cli\u003eNOx emission class: 6\u003c\/li\u003e\n\u003cli\u003eEfficiency 80°C-60°C at maximum output: 98.3%\u003c\/li\u003e\n\u003cli\u003eEfficiency 80°C-60°C at minimum output: 98.3%\u003c\/li\u003e\n\u003cli\u003eEfficiency 50°C-30°C at maximum output: 104.8%\u003c\/li\u003e\n\u003cli\u003eEfficiency 50°C-30°C at minimum output: 108.5%\u003c\/li\u003e\n\u003cli\u003eEfficiency at 30% partial load: 108.6%\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eOutput and performance\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eHeating heat input at maximum output: 113.00 kW\u003c\/li\u003e\n\u003cli\u003eHeating heat input at minimum output: 19.0 kW\u003c\/li\u003e\n\u003cli\u003eHeat output 80°C-60°C at maximum output: 110.5 kW\u003c\/li\u003e\n\u003cli\u003eHeat output 80°C-60°C at minimum output: 18.7 kW\u003c\/li\u003e\n\u003cli\u003eUseful heat output 50°C-30°C at maximum output: 117.00 kW\u003c\/li\u003e\n\u003cli\u003eUseful heat output 50°C-30°C at minimum output: 20.05 kW\u003c\/li\u003e\n\u003cli\u003eHeating operating pressure at maximum output: 6 bar\u003c\/li\u003e\n\u003cli\u003eHeating operating pressure at minimum output: 0.8 bar\u003c\/li\u003e\n\u003cli\u003eHeating water content: 5.6 l\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eInstallation and connections\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eFuel: natural gas or LPG\u003c\/li\u003e\n\u003cli\u003eSupply voltage: 230 V\u003c\/li\u003e\n\u003cli\u003eFrequency: 50 Hz\u003c\/li\u003e\n\u003cli\u003eProtection rating: IPX4D\u003c\/li\u003e\n\u003cli\u003eAir\/flue circuit: sealed chamber, certified B23, C13 and C33\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDimensions and weight\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eNet weight: 76 kg\u003c\/li\u003e\n\u003cli\u003eDimensions (W x H x D): 610 x 900 x 460\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMaterials and equipment\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eHeat exchanger: monobloc in aluminium-silicon alloy\u003c\/li\u003e\n\u003cli\u003eBurner: metal fibre micro-flame\u003c\/li\u003e\n\u003cli\u003eFunctions: flow and return sensors for constant ΔT operation, heat exchanger protection set at 95 °C, flue gas safety sensor, water pressure switch with a minimum threshold of 0.8 bar, non-return clapet valve on the flue duct\u003c\/li\u003e\n\u003cli\u003eHydraulic group: supplied as an accessory, with isolating valves and one three-way valve for venting to atmosphere, configurable with two standard or high-head circulation pumps\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Ferroli","offers":[{"title":"Default Title","offer_id":44282702757942,"sku":"50148721","price":4628.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0636\/9299\/6662\/files\/31493.jpg?v=1764685235"},{"product_id":"caldaia-a-condensazione-ferroli-alta-potenza-modello-force-w-60-kw-solo-riscaldamento","title":"Condensing Boiler Ferroli High Output Model Force W 60 kW Natural Gas\/LPG Code 0MDSAAWA - Heating Only","description":"\u003cp\u003eThe \u003cstrong\u003eFerroli Force W 60\u003c\/strong\u003e is a high-power condensing boiler for heating, designed for plant rooms in new builds and renovation projects. It has \u003cstrong\u003eERP energy class A\u003c\/strong\u003e, \u003cstrong\u003e98.3% efficiency at 80-60 °C\u003c\/strong\u003e and a \u003cstrong\u003emaximum thermal output of 57 kW\u003c\/strong\u003e, and runs on natural gas or LPG.\u003c\/p\u003e\u003cp\u003e\u003cimg alt=\"Illustrated panels showing the main features of a condensing boiler: heating account incentive, tax deduction\" style=\"float: none; display: block; margin-left: auto; margin-right: auto;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0902\/2177\/3121\/files\/Screenshot_2025-05-22_122433_600x600.png?v=1747909607\"\u003e\u003c\/p\u003e\u003ch2\u003eUp to 4 modules in cascade, 600 kW in total\u003c\/h2\u003e\u003cp\u003eEach module can be installed on its own or in a cascade configuration of up to four units, with INAIL certification, for a \u003cstrong\u003emaximum combined output of 600 kW\u003c\/strong\u003e. Hydraulic, gas and flue accessories are complete for configurations of 2, 3 or 4 modules. According to the datasheet, the efficiency allows access to economic incentives for energy renovation of climate systems.\u003c\/p\u003e\u003cp\u003e\u003cimg alt=\"White wall-mounted boiler with white flue outlet at the top and dark control panel at the bottom\" style=\"float: none; display: block; margin-left: auto; margin-right: auto;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0902\/2177\/3121\/files\/Screenshot_2025-05-22_122418_600x600.png?v=1747909526\"\u003e\u003c\/p\u003e\u003ch2\u003eMonobloc heat exchanger in aluminium-silicon alloy\u003c\/h2\u003e\u003cp\u003eThe \u003cstrong\u003emonobloc heat exchanger in aluminium-silicon alloy\u003c\/strong\u003e is designed to deliver maximum exchange efficiency and low pressure losses on the water circuit.\u003c\/p\u003e\u003ch2\u003eMetal fibre burner, class 6 according to EN 15502-1\u003c\/h2\u003e\u003cp\u003eThe premix combustion unit uses a \u003cstrong\u003emetal fibre micro-flame burner\u003c\/strong\u003e with very low pollutant emissions, in \u003cstrong\u003eclass 6 according to EN 15502-1\u003c\/strong\u003e. The modules can run on natural gas or LPG.\u003c\/p\u003e\u003csection data-ai-faq=\"1\" itemscope itemtype=\"https:\/\/schema.org\/FAQPage\"\u003e\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\u003csummary itemprop=\"name\"\u003eWhat systems is the Ferroli Force W 60 designed for?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003eThe Ferroli Force W 60 is designed for plant rooms in new builds and for renovating centralised systems.\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\u003csummary itemprop=\"name\"\u003eCan it be installed in cascade with other modules?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003eYes, the Ferroli Force W 60 can be installed singly or in a cascade of up to four modules, with INAIL certification, for a maximum combined output of 600 kW.\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\u003csummary itemprop=\"name\"\u003eDoes the Ferroli Force W 60 run on LPG?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003eYes, the modules of the Ferroli Force W 60 can run on natural gas or LPG.\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\u003csummary itemprop=\"name\"\u003eWhat protections does the Ferroli Force W 60 have?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003eThe Ferroli Force W 60 has flow and return sensors at constant ΔT, protection against heat exchanger overtemperature calibrated at 95 °C, a flue gas safety sensor and a water pressure switch with a minimum threshold of 0.8 bar.\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\u003csummary itemprop=\"name\"\u003eWhich flue types is the Ferroli Force W 60 compatible with?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003eThe air\/flue circuit of the Ferroli Force W 60 is sealed-chamber (room-sealed), certified B23, C13 and C33, with a non-return clapet valve on the flue exhaust duct.\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003c\/section\u003e\u003ch2\u003eSensors and protections: constant ΔT and 0.8 bar threshold\u003c\/h2\u003e\u003cp\u003eThe flow and return sensors work at constant ΔT. The heat exchanger is protected against overtemperature, calibrated at 95 °C. The flue gas safety sensor and the water pressure switch, with a minimum threshold of 0.8 bar, complete the protections.\u003c\/p\u003e\u003ch2\u003eRoom-sealed flue outlet B23, C13 and C33\u003c\/h2\u003e\u003cp\u003eThe sealed-chamber air\/flue circuit is certified B23, C13 and C33. A non-return clapet valve on the flue exhaust duct makes it possible to size the pressurised manifold.\u003c\/p\u003e\u003ch2\u003eHydraulic group with two circulation pumps\u003c\/h2\u003e\u003cp\u003eThe hydraulic group is supplied as an accessory and includes isolation valves, one of which is a three-way valve for venting to atmosphere. It can be configured with two circulation pumps, standard or high-head.\u003c\/p\u003e\u003ch2\u003eTechnical data sheet\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eModel and codes\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eModel: 0MDSAAWA W 60\u003c\/li\u003e\n\u003cli\u003ePower supply: natural gas or LPG\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eOutput and performance\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eMaximum heating thermal input: 58.0 kW\u003c\/li\u003e\n\u003cli\u003eMinimum heating thermal input: 15.0 kW\u003c\/li\u003e\n\u003cli\u003eMaximum thermal output 80-60 °C: 57 kW\u003c\/li\u003e\n\u003cli\u003eMinimum thermal output 80-60 °C: 14.7 kW\u003c\/li\u003e\n\u003cli\u003eMaximum useful thermal output 50-30 °C: 60.8 kW\u003c\/li\u003e\n\u003cli\u003eMinimum useful thermal output 50-30 °C: 16.3 kW\u003c\/li\u003e\n\u003cli\u003eMaximum heating operating pressure: 6 bar\u003c\/li\u003e\n\u003cli\u003eMinimum heating operating pressure: 0.8 bar\u003c\/li\u003e\n\u003cli\u003eHeating water content: 4.2 l\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEfficiency\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eMaximum efficiency 80-60 °C: 98.3 %\u003c\/li\u003e\n\u003cli\u003eMinimum efficiency 80-60 °C: 98.3 %\u003c\/li\u003e\n\u003cli\u003eMaximum efficiency 50-30 °C: 104.8 %\u003c\/li\u003e\n\u003cli\u003eMinimum efficiency 50-30 °C: 108.5 %\u003c\/li\u003e\n\u003cli\u003eEfficiency at 30% reduced load: 108.6 %\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEnergy efficiency\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eERP class: A\u003c\/li\u003e\n\u003cli\u003eNOx emission class: 6\u003c\/li\u003e\n\u003cli\u003eDegree of protection: IPX4D\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDimensions and weight\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eNet weight: 67 kg\u003c\/li\u003e\n\u003cli\u003eDimensions (W x H x D): 610 x 900 x 460\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eElectrical supply\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eSupply voltage: 230 V \/ 50 Hz\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Ferroli","offers":[{"title":"Default Title","offer_id":44282702790710,"sku":"50148684","price":2688.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0636\/9299\/6662\/files\/31464.jpg?v=1764685240"},{"product_id":"caldaia-a-condensazione-ferroli-alta-potenza-modello-force-w-80-kw-metano-solo-riscaldamento","title":"Condensing Boiler Ferroli High Output Model Force W 80 kW Natural Gas\/LPG Code 0MDSCAWA - Heating Only","description":"\u003cp\u003eThe \u003cstrong\u003eFerroli Force W 80\u003c\/strong\u003e (code 0MDSCAWA) is a high-power condensing boiler for heating only, designed for new builds and for renovating plant rooms. It has \u003cstrong\u003eERP energy class A\u003c\/strong\u003e and an efficiency of \u003cstrong\u003e98.3%\u003c\/strong\u003e at 80-60 °C. Each module works on its own or in a cascade of up to four units.\u003c\/p\u003e\u003cp\u003e\u003cimg alt=\"Illustrated panels showing the main features of a condensing boiler: heating account incentive, tax deduction\" style=\"float: none; display: block; margin-left: auto; margin-right: auto;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0902\/2177\/3121\/files\/Screenshot_2025-05-22_122433_600x600.png?v=1747909607\"\u003e\u003c\/p\u003e\u003ch2\u003eUp to 4 modules in cascade with INAIL certification\u003c\/h2\u003e\u003cp\u003eEach module is installed individually or in configurations of up to four units in cascade, with INAIL certification, for a maximum combined output of \u003cstrong\u003e600 kW\u003c\/strong\u003e. Complete hydraulic, gas and flue accessories are provided for configurations of 2, 3 or 4 modules.\u003c\/p\u003e\u003cp\u003e\u003cimg alt=\"White wall-mounted boiler with white flue outlet at the top and dark control panel at the bottom\" style=\"float: none; display: block; margin-left: auto; margin-right: auto;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0902\/2177\/3121\/files\/Screenshot_2025-05-22_122418_600x600.png?v=1747909526\"\u003e\u003c\/p\u003e\u003ch2\u003eMonobloc heat exchanger in aluminium-silicon alloy\u003c\/h2\u003e\u003cp\u003eThe monobloc heat exchanger in aluminium-silicon alloy is designed to deliver maximum exchange efficiency and low pressure losses on the water circuit.\u003c\/p\u003e\u003ch2\u003eMetal fibre micro-flame burner, class 6\u003c\/h2\u003e\u003cp\u003eThe premix combustion unit uses a \u003cstrong\u003emetal fibre burner\u003c\/strong\u003e with a micro-flame, with very low pollutant emissions: class 6 according to EN 15502-1. The modules run on natural gas or LPG.\u003c\/p\u003e\u003ch2\u003eProtections with constant ΔT sensors and flue gas safety\u003c\/h2\u003e\u003cp\u003eThe flow and return sensors work at constant ΔT. The heat exchanger is protected against overtemperature, calibrated at 95 °C. The flue gas safety sensor and the water pressure switch, with a minimum threshold of 0.8 bar, complete the protection.\u003c\/p\u003e\u003csection data-ai-faq=\"1\" itemscope itemtype=\"https:\/\/schema.org\/FAQPage\"\u003e\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\u003csummary itemprop=\"name\"\u003eWhat fuel does the Ferroli Force W 80 use?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003eThe Ferroli Force W 80 runs on natural gas or LPG: its modules can run on either fuel.\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\u003csummary itemprop=\"name\"\u003eHow many Ferroli Force W 80 boilers can be connected in cascade?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003eThe Ferroli Force W 80 can be installed singly or in a cascade of up to four units, with INAIL certification, for a maximum combined output of 600 kW.\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\u003csummary itemprop=\"name\"\u003eWhat NOx emission class does the Ferroli Force W 80 have?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003eThe Ferroli Force W 80 has NOx emission class 6 according to EN 15502-1, thanks to its metal fibre micro-flame burner.\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\u003csummary itemprop=\"name\"\u003eDoes the Ferroli Force W 80 have a sealed-chamber circuit?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003eYes, the Ferroli Force W 80 has a sealed-chamber air\/flue circuit certified B23, C13 and C33.\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\u003csummary itemprop=\"name\"\u003eHow much does the Ferroli Force W 80 weigh and what are its dimensions?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003eThe Ferroli Force W 80 has a net weight of 67 kg and dimensions W x H x D of 610 x 900 x 460.\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\u003csummary itemprop=\"name\"\u003eIs the hydraulic group included with the Ferroli Force W 80?\u003c\/summary\u003e\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\u003cdiv itemprop=\"text\"\u003eThe hydraulic group of the Ferroli Force W 80 is supplied as an accessory and can be configured with two circulation pumps, standard or high-head.\u003c\/div\u003e\u003c\/div\u003e\u003c\/details\u003e\u003c\/section\u003e\u003ch2\u003eSealed-chamber air\/flue circuit B23, C13 and C33\u003c\/h2\u003e\u003cp\u003eThe air\/flue circuit of the Ferroli Force W 80 is sealed-chamber, certified B23, C13 and C33. A non-return clapet valve on the flue exhaust duct makes it possible to size the pressurised manifold.\u003c\/p\u003e\u003ch2\u003eHydraulic group supplied as an accessory\u003c\/h2\u003e\u003cp\u003eThe hydraulic group is supplied as an accessory and has isolation valves, one of which is a three-way valve for venting to atmosphere. It can be configured with two circulation pumps, standard or high-head.\u003c\/p\u003e\u003ch2\u003eEfficiency up to 108.6% at reduced load and incentives\u003c\/h2\u003e\u003cp\u003eEfficiency is 98.3% at 80-60 °C and 104.8 \/ 108.5% at 50-30 °C (max \/ min), with 108.6% at 30% reduced load. Its efficiency allows access to the economic incentives available for energy renovation of climate systems.\u003c\/p\u003e\u003ch2\u003eTechnical data sheet\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eModel and codes\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eModel: 0MDSCAWA W 80\u003c\/li\u003e\n\u003cli\u003eERP class: A\u003c\/li\u003e\n\u003cli\u003eNOx emission class: 6\u003c\/li\u003e\n\u003cli\u003eDegree of protection: IPX4D\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eOutput and performance\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eHeating thermal input, max: 74.00 kW\u003c\/li\u003e\n\u003cli\u003eHeating thermal input, min: 15.0 kW\u003c\/li\u003e\n\u003cli\u003eHeating thermal output 80°C-60°C, max: 72.9 kW\u003c\/li\u003e\n\u003cli\u003eHeating thermal output 80°C-60°C, min: 14.7 kW\u003c\/li\u003e\n\u003cli\u003eUseful thermal output 50°C-30°C, max: 77.00 kW\u003c\/li\u003e\n\u003cli\u003eUseful thermal output 50°C-30°C, min: 16.3 kW\u003c\/li\u003e\n\u003cli\u003eEfficiency 80°C-60°C, max: 98.3 %\u003c\/li\u003e\n\u003cli\u003eEfficiency 80°C-60°C, min: 98.3 %\u003c\/li\u003e\n\u003cli\u003eEfficiency 50°C-30°C, max: 104.8 %\u003c\/li\u003e\n\u003cli\u003eEfficiency 50°C-30°C, min: 108.5 %\u003c\/li\u003e\n\u003cli\u003eReduced load 30%: 108.6 %\u003c\/li\u003e\n\u003cli\u003eHeating operating pressure, max: 6 bar\u003c\/li\u003e\n\u003cli\u003eHeating operating pressure, min: 0.8 bar\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWater, gas and power supply\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eHeating water content: 4.2 l\u003c\/li\u003e\n\u003cli\u003eFuel: natural gas or LPG\u003c\/li\u003e\n\u003cli\u003eSupply voltage: 230 V \/ 50 Hz\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDimensions and weight\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eNet weight: 67 kg\u003c\/li\u003e\n\u003cli\u003eDimensions (W x H x D): 610 x 900 x 460\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Ferroli","offers":[{"title":"Default Title","offer_id":44282702889014,"sku":"50148691","price":3278.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0636\/9299\/6662\/files\/31491.jpg?v=1764685245"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0636\/9299\/6662\/collections\/buytutto-it-collezione-caldaie-a-basamento.jpg?v=1762211417","url":"https:\/\/buytutto.com\/en-eu\/collections\/floor-standing-boilers.oembed","provider":"BuyTutto.com","version":"1.0","type":"link"}